Dell PowerVault TL4000 Betriebsanleitung Seite 73

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 80
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 72
DB External cooling fan error (fan motion has
stopped).
The subcode indicates which drive sled fan is
affected
Check if the indicated fan is
operational and not
obstructed.
If the error persists, contact
technical support
F0 Drive Overtemperature Condition
Subcode 00: drive sled #1
Subcode 01: drive sled #2
Check ambient temperature
conditions and check all fans,
after several occurrences
contact technical support
F1 Drive Communication Error,
Library controller has lost communication to drive
Subcode 00: drive sled #1
Subcode 01: drive sled #2
Retry operation; if not
successful contact technical
support
F2 Drive Sled not present
Subcode 00: drive sled #1
Subcode 01: drive sled #2
Retry operation; if not
successful contact technical
support
F3 Drive Hardware Error Cycle Power, after several
occurrences contact technical
support
F4 Drive Load Timeout
Drive has run in a timeout while loading a tape
Retry operation; if not
successful contact technical
support
F5 Drive Unload Timeout
Drive has run in a timeout while unloading a tape
Retry operation; if not
successful contact technical
support