4. Enter the name of the fabric in the Fabric Name field.
The fabric name must be a unique name. It can have from 1 to 17 characters. Valid characters are as follows:
alphanumeric
underscore ( _ )
+
When you specify the name of the fabric, AFM automatically names the switches in the fabric with the fabric name
as the prefix. For example, if the name of the fabric is EastFabric, the switch names assigned are EastFabric-
Spine-1 and EastFabric-Leaf1.
5. (Optional) In the Description field, enter the description of the fabric.
There is no character restriction. The length of the description can be from 1 and 128 characters.
6. If you are using the AFM Openstack, check the OpenStack Neutron Managed option.
NOTE: When you select this option, you cannot enter the VLAN configuration in the AFM Pre-Deployment
Wizard. This is handled by OpenStack which requires the AFM Neutron Plug-in installation which
orchestrates the Layer 2 VLAN configuration between OpenStack and AFM. See the
AFM Plug-in for
Openstack
Guide
.
7. To include blade switches (MXLs), check the Blade switch (MXL) deployment option. This option is for a Layer 2
fabric or Layer 3 with Resiliency (Routed VLT) fabric.
8. Click Next to go to the Bandwidth and Port Count screen to review the uplink and downlink bandwidth settings.
Uplinks connect from the fabric up to the next upstream tier of devices towards the core of the network. Downlinks
connect from the fabric down to the next tier of devices or servers towards the edge of the network.
Fabric Design – Step 2: Bandwidth and Port Count
The Bandwidth and Port Count screen displays the default values for the fabric uplinks and downlinks. Uplinks connect
from the fabric up to the next upstream tier of devices toward the core of the network. The minimum number of uplinks is
2. One uplink is for redundancy. Downlinks connect from the fabric down to the next tier of devices or servers towards
the edge of the network. These values (1 Gb, 10 Gb, or 40 Gb) are based on the options you have selected in the
Fabric
Name and Type screen. The number of uplink ports, downlink ports, and bandwidth you enter are the major input
parameters in the design phase.