8. Map the system MAC address, serial number, and service tag to each switch.
9. Click Next to the go to the Assign Management IP screen.
Pre-Deployment – Step 3: Management IP
To assign a management IP address to each switch in the fabric, use the Management IP screen.
NOTE: Before you begin, gather the management IP addresses for all the switches in the Layer 2 or Layer 3 fabric
for the management port. All management switch IP addresses must be on the same subnet.
To assign a management IP address to the switches in the fabric:
1. Navigate to the Network >
Fabric Name
> Configure and Deploy screen.
2. From the Deploy Fabric pull-down menu, select the Pre-deployment Configuration option.
3. Navigate to the Management IP screen.
4. In the Default Gateway field, enter the address of the default gateway for the management interface.
5. In the Management Route field, enter the route and prefix of the management interface.
6. In the Start Management IP Address/Prefix fields, enter the starting management IP address and prefix.
7. Select the switches to assign a management IP address.
8. Click the Auto-fill Selected Rows button.
The system automatically assigns a management IP address to all the selected switches in the fabric.
9. Click Next to go to the Software Images screen.
Pre-Deployment – Step 4: SNMP and CLI Credentials
Use this screen to configure SNMP and CLI credentials at the fabric level. Configure SNMP so that the AFM can perform
SNMP queries on the switches in the fabric. The values you enter in the SNMP configuration are also used for
configuring the switches during the build phase and for monitoring during the run phase. The write community string is
populated from the AFM global setting, which is configure during installation. To provision the fabric, enter the FTOS CLI
user’s credentials and enable the configuration credential for all the switches in the fabric. This option allows you to
remotely make configuration changes to the switches in the fabric.
To configure SNMP and CLI credentials:
1. Navigate to the Network >
Fabric Name
> Configure and Deploy screen.
2. From the Deploy Fabric pull-down menu, select the Pre-deployment Configuration option.
3. Navigate to the SNMP and CLI Credentials screen.
4. Navigate to the SNMP Configuration area.
5. In the Read Community String field, enter the read community string. For example, "public".
6. In the Write Community String field, enter the write community string. For example, "private".
7. Navigate to the CLI Credentials area.
8. In the Protocol pull-down menu, select one of the following options: Telnet or SSHv2.
9. In the User Name field, enter the user name.
10. In the Password field, enter the password.
11. In the Confirm Password field, confirm the password. The privilege level is a read-only field and is set at 15.
12. In the Enable Password field, enter a password for the privilege level.
13. In the Confirm Enable Password field, confirm the enabled password for the privilege level.
14. Click Next.