5. Add the /LUNS switch to the load line of the appropriate SCSI driver. If a dual
channel card is installed and the user is unsure which channel the LUN device
is attached to, simply edit both lines.
LOAD ADPT160M.HAM SLOT=201 /LUNS
LOAD ADPT160M.HAM SLOT=202 /LUNS
6. After the STARTUP.NCF file has been edited, save the file and reboot the server
to activate the new STARTUP.NCF.
7. Upon reboot navigate to the System Console and type scan all. This will start
a scan of all the LUNS on each adapter.
8. When the scan is complete, verify the LUN device has been detected using the
list storage adapters command. Typical output with both the tape drive and
loader being recognized:
0x08 [V321-A3] Adaptec SCSI Card 39160/3960D - Ultra160 SCSI [slot 201]
0x16 [V321-A3-D5:1] DELL PV-124T 0031
0x15 [V321-A3-D5:0] IBM ULTRIUM-TD3 5BG2
0x09 [V321-A4] Adaptec SCSI Card 39160/3960D - Ultra160 SCSI [slot 202]
Netware may display unbound device, meaning a driver is not bound to the
loader unless a driver from a backup software is loaded. This does not prevent
the backup application from detecting the LUN and binding the appropriate
driver.
Note:
The user must type the command scan all upon OS boot every time. If
backup software services automatically start on OS boot, the user must
disable them, run the scan all command, and re-enable the services.