• Updates
• Audit
• Config
• Worknotes
Valid Severity values are:
• Critical
• Warning
• Info
Valid examples of alert descriptors are:
• idrac.alert.all
• idrac.alert.audit
• idrac.alert.audit.lic
• idrac.alert.audit.warning
• idrac.alert.audit.lic.critical
Input
• get — Displays the list of eventfilter settings.
• set — Configures the actions and notifications for a given eventfilter configuration.
• -i — Message ID for which the simulation is needed.
• -c — Alert descriptor of the specific event filter.
• -a — The action that must be invoked when the event occurs. Valid values are none,
powercycle, power off, or systemreset.
• -n — The notification is sent when the event occurs. Valid values are all, snmp, ipmi, lcd,
email, remotesyslog or none. You can append multiple notifications separating by a
comma. You cannot enter the valuesall or none with other notifications.
• -r — Event generation interval. This option is applicable only to the temperature statistics
subcategory — tmps. You can use this option as a stand-alone or with -n and -a.
NOTE: If both event generation interval and notifications are configured and there is an error
while configuring the notifications, the event generation interval is not set. The valid values are
0–365. 0 disables the event generation.
Example
• Display all available event filter configurations:
racadm eventfilters get -c idrac.alert.all
• Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c idrac.alert.audit
• Display eventfilter configurations for a specific subcategory. For example, licensing under the
audit category:
racadm eventfilters get -c idrac.alert.audit.lic
• Display eventfilter configurations for a specific severity. For example, warning under the audit
category:
racadm eventfilters get -c idrac.alert.audit.warning
• Display eventfilter configurations for a specific severity and subcategory. For example, a severity
of warning in the subcategory licensing under audit category:
racadm eventfilters get -c idrac.alert.audit.lic.warning
• Clear all available alert settings:
racadm eventfilters set -c idrac.alert.all -a none -n none