Example
• racadm setassettag -m chassis 783839–33
• racadm setassettag 783839–33
The asset tag was changed successfully.
setchassisname
Description Sets the name of the chassis in the LCD.
This subcommand is applicable only for CMC.
To run this subcommand, you must have the Administrator privilege.
Synopsis
racadm setchassisname <name>
NOTE: Chassis name is a maximum of 64 nonextended ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
setflexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
This subcommand is applicable only for CMC.
To run this subcommand, you must have the Chassis Configuration Administrator privilege.
If the fabric type is determined to be InfiniBand, the operation is canceled and the command returns
an error. If the FlexAddress feature is not activated, the command returns an error.
NOTE: The server must be turned off to change the slot state. All servers must be turned off to
change the fabric state. The MAC/WWN addresses must be managed locally (not by an external
console) to run this command.
Synopsis
racadm setflexaddr -i <slotNum> 0|1
racadm setflexaddr -f <fabricName> 0|1
<slotNum>=1–16
<fabricName>=A, B, C, iDRAC
• 0: disable
• 1: enable
Input
• -i <slotNum> — Enables or disables FlexAddress for the specified slot.
• -f <fabricName> — Enables or disables FlexAddress for the specified fabric.
Example
• Disable flex address for slot 2.
racadm setflexaddr -i 2 0
• Enable flex address for fabric A.
racadm setflexaddr -f A 1
• Disable flex address for fabric B.
racadm setflexaddr -f b 0
121