BIOS.ProcSettings.ProcCoreSpeed (Read Only)
Description
Clock speed of the processor.
Legal Values
None
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.ProcSettings.ProcDramPrefetcher (Read or Write)
Description
Enable to turn on the DRAM prefetch unit in the Northbridge. Disable to prevent DRAM references
from triggering DRAM prefetch requests.
Legal Values
Enabled
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.ProcSettings.ProcExecuteDisable (Read or Write)
Description
Specifies whether Execute Disable Memory Protection Technology is enabled or disabled.
Legal Values
Enabled
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.ProcSettings.ProcHpcMode (Read or Write)
Description
Configure processor's HPC mode.
Legal Values
Enabled
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None