cfgServerPowerSupplyMaxOutputPower (Read Only)
Description
Displays the AC output rated power in Watts.
Legal Values
A string of up to 32 characters.
Default
0
cfgServerPowerSupplyOnlineStatus (Read Only)
Description
Displays the status of the PSU.
Legal Values
0 — Present
1 — Absent
2 — Failure
3 — Predictive failure
Default 0 — Present
cfgServerPowerSupplyFwVer (Read Only)
Description
Displays the firmware version of the PSU, in the format x.xx.xxx.
Legal Values
A string up to 8 characters.
Default
Null
cfgServerPowerSupplyCurrentDraw (Read Only)
Description
Displays the instantaneous current consumption in 0.1 amps.
Legal Values
A string of up to 32 characters.
Default
0
cfgServerPowerSupplyType
Description
Displays whether the power supply is AC or DC.
Legal Values
A string of up to 32 characters.
Default
0
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.