Dell Chassis Management Controller Version 4.50 Betriebsanweisung Seite 322

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 428
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 321
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.SNMP.TrapFormat (Read or Write)
Description
Specifies the SNMP format.
Legal Values
0 — SNMPv1
1 — SNMPv2
Default Value
0 — SNMPv1
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.SNMP.Alert
The objects in this group configures the SNMP alert settings.
This group is indexed from 1 to 8.
iDRAC.SNMP.Alert.DestAddr (Read or Write)
Description
IPv4, IPv6 or FQDN address of the target destination to receive alters.
Legal Values
Valid IPv4 or IPv6 or FQDN address
Default Value
Index 1–4 — 0.0.0.0
Index 5–8 — ::
Write Privilege
Configure iDRAC
License
Required
None
Dependency
None
iDRAC.SNMP.Alert.Enable (Read or Write)
Description
Enables or disables SNMP alert for the given index.
Legal Values
0 — Disabled
1 — Enabled
Write Privilege
Configure iDRAC
322
Seitenansicht 321
1 2 ... 317 318 319 320 321 322 323 324 325 326 327 ... 427 428

Kommentare zu diesen Handbüchern

Keine Kommentare