iDRAC.ActiveDirectory.RacDomain (Read or Write)
Description
Active Directory Domain in which iDRAC resides.
Legal Values
String of up to 254 ASCII characters
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Enterprise
Dependency
None
iDRAC.ActiveDirectory.RacName (Read or Write)
Description
Name of iDRAC as recorded in the Active Directory forest.
Legal Values
String of up to 254 ASCII characters
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Enterprise
Dependency
None
iDRAC.ActiveDirectory.Schema (Read or Write)
Description
To use with Active Directory, determine the schema type.
Legal Values
1 — Extended Schema
2 — Standard Schema
Default Value
1 — Extended Schema
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Enterprise
Dependency
None
iDRAC.ActiveDirectory.SSOEnable (Read or Write)
Description
Enables or disables Active Directory single sign-on authentication on iDRAC.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
271