74 Configuring the iDRAC6 Using the Web Interface
Table 4-17. Telnet Settings
Setting Description
Enabled Enables or disables Telnet. When checked, Telnet is enabled.
Max Sessions Maximum number of simultaneous Telnet sessions allowed
for this system. You cannot edit this field.
NOTE: iDRAC6 supports up to 2 Telnet sessions
simultaneously.
Active Sessions Number of current Telnet sessions on the system, less than
or equal to the setting for Max Sessions. You cannot edit
this field.
Timeout The Telnet idle timeout in seconds. Timeout range is 60 to
10800 seconds. Enter 0 seconds to disable the Timeout
feature. The default is 1800.
Port Number The port on which the iDRAC6 listens for a Telnet
connection. The default is 23.
Table 4-18. Remote RACADM Settings
Setting Description
Enabled Enables/disables remote RACADM. When checked, remote
RACADM is enabled.
Active Sessions The number of current remote RACADM sessions on the
system. You cannot edit this field.
Table 4-19. SNMP Settings
Setting Description
Enabled Enables/disables SNMP. When checked, SNMP is enabled.
SNMP Community
Name
Enables/disables the SNMP Community Name.
When checked, the SNMP Community Name is enabled.
Define the SNMP community string to be used. The
Community Name may be up to 31 characters (without
spaces) in length. The default is public.