330 Recovering and Troubleshooting the Managed System
NOTE: If the CSIOR (Collect System Inventory on Reboot) is not enabled, it takes
some time to collect the data, So it is recommended to run the CSIOR first and
collect the system inventory on the reboot, and then click the System Inventory tab.
After new hardware addition or removal to the system, the System Inventory
page may not update the changes automatically. This is because inventory
data collected during manufacturing process may not be updated with new
changes.
To solve this, during BIOS POST select the Cntl+E option and enable
Collect system Inventory on reboot. Save and exit from the Cntl+E option.
The system reboots to collect new system inventory. After inventory
collection is completed, the System Inventory page displays correct hardware
and software inventory data.
For more information, see the iDRAC6 Online Help.