Dell IDRAC6 Betriebsanweisung Seite 167

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 372
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 166
Using the iDRAC6 Directory Service 167
NOTE: The Bit Mask values are used only when setting Standard Schema
using RACADM.
Single Domain Versus Multiple Domain Scenarios
If all the login users and role groups, and the nested groups, are in the same
domain, then only the domain controllers’ addresses must be configured on
iDRAC6. In this single domain scenario, any group type is supported.
If all the login users and role groups, or any of the nested groups, are from
multiple domains, then Global Catalog server addresses are required to be
configured on iDRAC6. In this multiple domain scenario, all the role groups
and the nested groups, if any, must be a Universal Group type.
Configuring Standard Schema Microsoft Active
Directory to Access iDRAC6
You must perform the following steps to configure Active Directory before an
Active Directory user can access iDRAC6:
1
On an Active Directory server (domain controller), open the
Active
Directory Users and Computers Snap-in.
2
Create a group or select an existing group. Add the Active Directory user
as a member of the Active Directory group to access the iDRAC6.
Table 7-9. Default Role Group Privileges
Privilege Level Permissions Granted Bit Mask
Administrator Login to iDRAC, Configure iDRAC,
Configure Users, Clear Logs, Execute Server
Control Commands, Access Virtual
Console, Access Virtual Media, Test Alerts,
Execute Diagnostic Commands
0x000001ff
Operator Login to iDRAC, Configure iDRAC,
Execute Server Control Commands, Access
Virtual Console, Access Virtual Media, Test
Alerts, Execute Diagnostic Commands
0x000000f9
Read Only Login to iDRAC 0x00000001
None No assigned permissions 0x00000000
Seitenansicht 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 371 372

Kommentare zu diesen Handbüchern

Keine Kommentare