System Messages
System messages appear on the screen to notify you of a possible problem with the system. Table1-6 lists the system messages that can occur and the
probable cause and corrective action for each message.
Table 1-6.SystemMessages
The green power-on/fault indicator is on.
NOTE: If you receive a system message that is not listed in Table1-6, check the documentation for the application that is running when the message
appears or the operating system's documentation for an explanation of the message and recommended action.
Amount of available memory
limited to 256 MB
the System Setup program.
System Setup program. See
Using the System Setup
Program.
Attempting to update Remote
Configuration. Please wait...
Remote Configuration is in
progress.
Wait until the process is
complete.
BIOS Update Attempt Failed
BIOS remote update failed.
Caution! NVRAM_CLR jumper
is installed on system board.
NVRAM_CLR jumper is
installed.
Remove the NVRAM_CLR
jumper. See Jumpers and
Connectors for the jumper
location.
Faulty diskette, diskette
drive, optical drive, hard
drive.
Replace the diskette. Ensure
that the diskette drive, optical
drive, and hard- drive cables
are properly connected. See
Troubleshooting a Diskette
Drive or Troubleshooting an
Optical Drive for the
appropriate drive(s) installed
in your system.
Decreasing available memory
Faulty or improperly installed
memory modules.
modules are properly installed.
See Troubleshooting System
Memory.
Diskette drive 0 seek failure
Incorrect configuration
settings in System Setup
program.
Run the System Setup
program to correct the
settings. See Using the
System Setup Program.
Faulty or improperly inserted
diskette.
Diskette subsystem reset
failed
Faulty diskette drive or optical
Ensure that the diskette drive
and optical drive cables are
properly connected. See
Troubleshooting a Diskette
Drive and Troubleshooting an
Optical Drive. If the problem
persists, see Getting Help.
Diskette missing or improperly
inserted in diskette drive.
Reinsert or replace the
diskette.
Error: Incorrect memory
configuration. Ensure memory
in slots DIMM1_A and
DIMM1_B, DIMM2_A and
DIMM2_B match identically in
size, speed, and rank.
An unmatched pair of memory
Install a matched pair of
memory modules, or remove
the memory module in socket
DIMM1_B. See
Module Installation Guidelines.
Error: Remote Access Card
initialization failure.
Faulty or improperly installed
RAC.
Ensure that the RAC is
properly installed. See
Troubleshooting Expansion
Cards.
Error 8602: Auxiliary device
failure. Verify that the mouse
and keyboard are securely
attached to correct
connectors.
Loose or improperly
connected mouse or
keyboard cable; faulty mouse
or keyboard.
Replace the mouse. If the
problem persists, replace the
keyboard.
Faulty keyboard controller
(faulty system board).
Operating system corrupted
or improperly installed.
Reinstall the operating system.
IDE Primary drive x not found
Improperly connected or
missing optical drive or tape
backup unit.
Ensure that the drive cables
are properly connected. See
Troubleshooting Your System
for the appropriate drive
installed in your system.
If no drive is installed, disable
the IDE controller. See Using
the System Setup Program.
Invalid memory configuration
detected. Potential for data
corruption exists!
installed in the system, or the
memory configuration is
incorrect.
Replace or reconfigure the
DIMMs. See Memory for
memory configuration
guidelines, a list of supported
DIMMs, and supported memory