Figure A-6. Bound Volumes/Devices Tab in iSCSI Initiator Properties Window
Advanced Configuration Details
Enabling Multi-Path on the Initiator
After you establish the iSCSI Initiator-Target connection, perform the
following steps to enable multi-path operation:
1
On the Initiator, go to
iSCSI Initiator Properties
Ta rg et s
tab
Log
On...
Log On to Target
window and select the check box for
Enable
multi-path
option.
2
You must configure multiple NIC ports for iSCSI operation for efficient
block (iSCSI) I/O operations and for provisioning link failover. Multi-path
option also enables multiple connections for the same iSCSI Targets using
different IP addresses.