EMC CLARiiON Integration with
Figure 3. Executing the lunmapinfo command issued on a Windows virtual machine and
sent to the Navisphere Agent on the ESX service console
You can use the symm inq utility to get device mapping information from the virtual machine to the
CLARiiON LUN level. The virtual disks assigned to the virtual machine must be configured as raw
mapped LUN for this to work correctly.
Figure 4 shows output for the inq –clar_wwn command.
Figure 4. Output for the inq –clar_wwn command that provides device mapping
information from the virtual machine level to the CLARiiON LUN level
Navisphere Server Utility software can determine the ESX server configuration and check to see if the
VMware ESX configuration is a high-availability environment. Support for VMware ESX with the
Navisphere Server Utility is available with FLARE 28.
The Navisphere Server Utility must be installed on a Windows server to communicate with the VMware
ESX 4.0, ESX 3.x, and ESXi or VMware vCenter server.
Figure 5 shows how to enter the credentials for
VMware vCenter using the Navisphere Server Utility. You can now view the report generated by the server
utility for a particular ESX server.
VMware ESX Server
Applied Technology 15