Scenario 2 — Forwarding Alerts in the Original Format Using SNMP v2/v2c Protocol
In this scenario, SNMP v2 alerts are sent from MNv2 to MS1 and then forwarded from MS1 to MS3. If you try to retrieve
the remote host of the forwarded alert from MS3, it is displayed as MS1
Since there are no fields in an SNMP v2 alert to specify the agent name, the host which sends the alert is assumed as
the agent. When an SNMP v2 alert is forwarded from MS1 to MS3, MS1 is considered as the source of problem. To
resolve this issue, while forwarding SNMP v2 or v2c alerts, a varbind is added with OID as .1.3.6.1.6.3.18.1.3.0 with the
variable value as Agent Address. This has been set based on the standard OID specified in RFC2576-MIB. When you try
to retrieve the Agent Address from MS3, it is displayed as MNv2
NOTE: If the SNMP v2 alert is forwarded from MS1 to MS2, the remote host is displayed as MNv2 because MS1
parses the extra OID along with the forwarded trap.
Scenario 3 — Forwarding Alerts in the OMEssentials Format Using Either SNMP v1/v2 Protocol
In this scenario, SNMP v1 alerts are sent from MNv1 to MS1 and then forwarded to MS2. If you try to retrieve the remote
host of the forwarded alert, it is displayed as MS1. The severity and the message of the alert is also defined by MS1 and
does not display the original severity and message defined by MNv1.
NOTE: The same behavior applies for SNMPv2 traps.
Working With Sample Alert Action Use Cases
Sample alert actions are available for the Application Launch, E-mail, Ignore, and Trap Forwarding alert actions. Sample
alert action use cases are disabled by default. Click the sample alert actions to enable the sample alert action.
To enable a sample use case, right-click the use case and select Enable.
Use Cases in Alert Actions
Application Launch
Sample - Run Script on Server Critical Alert—Enable this use case to run a custom script when a critical alert is
received.
Email
Sample - Email Alerts to Service Desk—Enable this use case to send an e-mail to the service desk account from
the OpenManage Essentials server when an alert criteria is matched.
Sample - Email Critical Server Alerts to Admin—Enable this use case to send an e-mail to an administrator from
the OpenManage Essentials server when an alert criteria is matched.
Ignore
Sample - Ignore Alerts During Maintenance Window—Enable this use case to ignore alerts during a specified
time interval.
Sample - Ignore Duplicate Alerts with 15s—Enable this use case to ignore duplicate alerts from the same
system.
Sample - Ignore Non-Critical Alerts from Printers—Enable this use case to ignore non-critical alerts related to
printers.
Trap Forwarding
Sample - Forward Critical Server Alerts to Other Monitoring Console—Enable this use case to forward SNMP alerts
another monitoring console.
119