NOTE: If the SNMP v2 alert is forwarded from MS1 to MS2, the remote host is displayed as MNv2 because MS1
parses the extra OID along with the forwarded trap.
Scenario 3 — Forwarding Alerts in the OMEssentials Format Using Either SNMP v1/v2 Protocol
In this scenario, SNMP v1 alerts are sent from MNv1 to MS1 and then forwarded to MS2. If you try to retrieve the remote
host of the forwarded alert, it is displayed as MS1. The severity and the message of the alert is also defined by MS1 and
does not display the original severity and message defined by MNv1.
NOTE: The same behavior applies for SNMPv2 traps.
Working With Sample Alert Action Use Cases
Sample alert actions are available for the Application Launch, E-mail, Ignore, and Trap Forwarding alert actions. Sample
alert action use cases are disabled by default. Click the sample alert actions to enable the sample alert action.
To enable a sample use case, right-click the use case and select Enable.
Use Cases in Alert Actions
Application Launch
Sample - Run Script on Server Critical Alert—Enable this use case to run a custom script when a critical alert is
received.
Email
Sample - Email Alerts to Service Desk—Enable this use case to send an e-mail to the service desk account from
the OpenManage Essentials server when an alert criteria is matched.
Sample - Email Critical Server Alerts to Admin—Enable this use case to send an e-mail to an administrator from
the OpenManage Essentials server when an alert criteria is matched.
Ignore
Sample - Ignore Alerts During Maintenance Window—Enable this use case to ignore alerts during a specified
time interval.
Sample - Ignore Duplicate Alerts with 15s—Enable this use case to ignore duplicate alerts from the same
system.
Sample - Ignore Non-Critical Alerts from Printers—Enable this use case to ignore non-critical alerts related to
printers.
Trap Forwarding
Sample - Forward Critical Server Alerts to Other Monitoring Console—Enable this use case to forward SNMP alerts
another monitoring console.
Configuring Alert Log Settings
You can configure alert log settings to set the maximum size of alert logs; to generate a warning alert when the alert log
reaches a set threshold, and to purge the alert logs. To modify the default settings:
1. Select ManageAlertsCommon TasksAlert Log Settings.
2. Enter a value or use the increment/decrement arrow buttons to increase or decrease the value.
NOTE: The default maximum size of alert logs is 20,000 alerts. Once that value is reached, the older alerts are
purged.