228 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgChassisPowerCapPercent (Read/Write)
cfgChassisPowerCapFPercent (Read/Write)
cfgChassisRedundancyPolicy (Read/Write)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Indicates the power consumption limit as a percentage. The
percentage is computed mathematically as the minimum power +
(percent * (maximum power - minimum power)). The command
generates an error if server throttling is necessary to achieve the
power goal based on the value for this setting.
Legal Values 16 -100
Default 100
Description Indicates the power consumption limit as a percentage. The
percentage is computed mathematically as the minimum power +
(percent * (maximum power - minimum power)). Use
cfgChassisPowerCapFPercent when power consumption is to be
changed regardless of whether server throttling is required.
Legal Values 16 -100
Default 100
Description Sets the redundancy policy of the chassis.
Legal Values 0 (no redundancy)
1 (AC redundancy)
2 (power supply redundancy)
Default 0 (no redundancy)
Description Enables or disables dynamic engagement.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)