Dell Computer Drive CMC 3.2 Bedienungsanleitung Seite 185

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 292
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 184
iDRAC6 and CMC Property Database Group and Object Descriptions 185
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
NOTE: The prompt counts as two characters.
NOTE: The terminal emulator must be configured with the line wrap mode ON, if a
terminal emulator is used.
NOTE: You must log out, then log in again for the changes to take effect.
cfgSerialHistorySize (Read/Write)
cfgSerialCom2RedirEnable (Read/Write)
The cfgSerialCom2RedirEnable object property is applicable only for iDRAC6 on
Rack and Tower Servers. It is not applicable for iDRAC6 Enterprise on Blade Servers and
CMC.
cfgSerialSshEnable (Read/Write)
Description Specifies the maximum size of the serial history buffer.
Legal Values 0 – 8192
Default 8192
Description Enables or disables the console for COM 2 port redirection.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1
Description Enables or disables the secure shell (SSH) interface on iDRAC6 or
CMC.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1
Seitenansicht 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 291 292

Kommentare zu diesen Handbüchern

Keine Kommentare