Dell OpenManage Server Administrator Version 6.5 Betriebsanweisung Seite 736

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 776
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 735
738 Traps
Pluggable Device Traps
Server Administrator monitors the addition and removal of pluggable devices
such as memory cards. Device traps provide information about the addition
and removal of such devices.
Processor Device Status Failure
1604 Processor sensor
detected a failure
value
Sensor Location:
<Location in chassis>
Chassis Location: <Name
of chassis>
Previous state was:
<State>
Processor sensor
status: <status>
Error A processor sensor in the
specified system is disabled,
has a configuration error, or
experienced a thermal trip.
The sensor location, chassis
location, previous state and
processor sensor status are
provided.
Table 27-15. Pluggable Device Traps
Trap ID Description Severity Cause
Pluggable Device Addition
1651 Device added to system
Device Location:
<Location in chassis>
Chassis Location: <Name
of chassis>
Additional Details:
<Additional details for
the events>
Information A device was added to the
specified system. The
device location, chassis
location, and additional
event details, if available,
are provided.
Table 27-14. Processor Device Status Traps
(continued)
Trap ID Description Severity Cause
book.book Page 738 Monday, March 14, 2011 3:01 PM