Traps 719
Table 27-3. Temperature Probe Traps
Trap ID Description Severity Cause
Temperature Probe Normal
1052 Temperature sensor returned
to a normal value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was: <State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
returned to a valid
range after crossing a
failure threshold.
The sensor location,
chassis location,
previous state, and
temperature sensor
value are provided.
Temperature Probe Warning
1053 Temperature sensor detected
a warning value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was: <State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Warning A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
book.book Page 719 Monday, March 14, 2011 3:01 PM