228 Storage Management Message Reference
2396 The Check
Consistency
detected
uncorrectable
multiple
medium errors
Critical /
Failure / Error
Cause: The Check
Consistency task
detects uncorrectable
multiple errors.
Action: Replace the
failed physical disk. You
can identify the failed
disk by locating the disk
that has a red “X” for its
status. Rebuild the
physical disk. When
finished, restart the
check consistency
operation.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1204
2397 The Check
Consistency
completed
with
uncorrectable
errors
Critical /
Failure / Error
Cause: The Check
Consistency task
detected uncorrectable
multiple errors.
Action: Replace the
failed physical disk. You
can identify the failed
disk by locating the disk
that has a red “X” for its
status. Rebuild the
physical disk. When
finished, restart the
check consistency
operation.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1204
2398 The Manage
Physical Disk
Power
property(s)
changed
OK / Normal /
Informational
Cause: The Manage
Physical Disk Power
properties are changed.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Seitenansicht 227