Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Betriebsanweisung Seite 185

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 292
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 184
Storage Management Message Reference 185
2301 The enclosure
has a hardware
error.
Critical /
Failure / Error
Cause: The enclosure or
an enclosure
component is in a
Failed or Degraded
state.
Action: Check the
health of the enclosure
and its components.
Replace any hardware
that is in a Failed state.
See the hardware
documentation for
more information.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2302 The enclosure
is not
responding.
Critical /
Failure / Error
Cause: The enclosure or
an enclosure
component is in a
Failed or Degraded
state.
Action: Check the
health of the enclosure
and its components.
Replace any hardware
that is in a Failed state.
See the hardware
documentation for
more information.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
854
2303 The enclosure
cannot support
both SAS and
SATA physical
disks. Physical
disks may be
disabled.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
851
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Seitenansicht 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 291 292

Kommentare zu diesen Handbüchern

Keine Kommentare