172 Storage Management Message Reference
2273 A block on the
physical disk
has been
punctured by
the controller.
Critical /
Failure / Error
Cause: The controller
encountered an
unrecoverable medium
error when attempting
to read a block on the
physical disk and
marked that block as
invalid. If the error was
encountered on a
source physical disk
during a rebuild or
reconfigure operation,
it also punctures the
corresponding block on
the target physical disk.
The invalid block is
cleared during a write
operation.
Action: Back up your
data. If you are able to
back up the data
successfully, initialize
the disk and restore
from the back up.
Clear Alert:
None
Related
Alert: 2095,
2350
LRA
Number:
2071
904
2274 The physical
disk rebuild
has resumed.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
901
Table 3-4. Storage Management Messages