5
Power Supplies
The S4810–ON supports two hot-swappable power supply units (PSUs) with integrated fans that provide
cooling for the system.
The S4810–ON supports AC power supplies with two air-flow directions (normal and reversed). Two
PSUs are required for full redundancy, but the system can operate with a single PSU.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell Networking
recommends using power supply 2 (PSU2) as the blank plate slot.
The PSUs are field replaceable. When running with full redundancy (two power supplies installed and
running), you can remove and replace one PSU while the other PSU is running without disrupting traffic.
The power supply LED indicates the power supply status:
Off — no power
Solid Green — Power supply is present and working
WARNING: ESD damage can occur if components are mishandled. Always wear an ESD-
preventive wrist or heel ground strap when handling the S4810–ON and its components.
WARNING: To prevent electrical shock, ensure that the S4810–ON is grounded properly. If you
ground your equipment incorrectly, excessive emissions may result. To ensure that the power
cables meet your local electrical requirements, use a qualified electrician.
Components
The following power supply options are available for the S4810–ON.
AC power supply with integrated fan
AC power supply with integrated reverse flow fan
Power supply 1 (PSU1) is on the left side of the chassis; power supply 2 (PSU2) is on the right side of the
chassis.
The PSUs in the S4810–ON are field replaceable. When both power supplies are installed and running,
you can remove one power supply without interrupting traffic.
The PSUs are in a single piece with the PSU fans. You can replace the fan trays individually, but you
cannot replace the fans that are attached to the PSUs — if the fans attached to the PSU fail, you must
replace the entire PSU. For fan tray replacement procedures, refer to Fans.
WARNING: Prevent exposure and contact with hazardous voltages. Do not attempt to operate
this system with the safety cover removed.
CAUTION: Remove the power cable from the PSU prior to removing the PSU. Also, do not
connect the power cable before you insert the PSU in the chassis.
NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power
Ports, use an external SPD at the AC input of the router.
Power Supplies