Dell
DELL PERC H700 and H800 Technical Guide 16
Table 8. RAID Level Migration
# of Physical
Drives
(Beginning)
# of Physical
Drives (End)
Capacity
Expansion
Possible
Converting non-
redundant virtual disk
into a mirrored virtual
disk by adding one drive.
At least one drive needs
to be added for
distributed parity data.
At least two drives need
to be added for dual
distributed parity data.
Removes redundancy
while increasing
capacity.
Maintains redundancy
while doubling capacity.
Two drives are required
to be added for
distributed parity data.
Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.
At least one drive needs
to be added for dual
distributed parity data.
Converting to a non-
redundant virtual disk
and reclaiming disk space
used for distributed
parity data.
Removing one set of
parity data and
reclaiming disk space
used for it.
4.5 Fault-Tolerance Features
Below is a list of features that provide fault tolerance to prevent data loss:
Non-volatile cache: extends data retention from hours to years
Support for SMART
Redundant path support (for PERC H800 only)
Physical disk failure detection