Dell UCS-51 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Festplatten-Arrays Dell UCS-51 herunter. Dell UCS-51 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.dell.com | support.dell.com
Dell™ Serial-Attached SCSI 5/iR
Integrated and Adapter
User’s Guide
Model UCS-51
YD912bk1.book Page 1 Monday, April 2, 2007 4:39 PM
Seitenansicht 0
1 2 3 4 5 6 ... 67 68

Inhaltsverzeichnis

Seite 1 - User’s Guide

www.dell.com | support.dell.comDell™ Serial-Attached SCSI 5/iRIntegrated and AdapterUser’s GuideModel UCS-51YD912bk1.book Page 1 Monday, April 2, 20

Seite 2

8 Safety InstructionsIn addition, take note of these safety guidelines when appropriate:• When you disconnect a cable, pull on its connector or on its

Seite 3

Overview 9OverviewThe Dell™ Serial-Attached SCSI (SAS) 5/iR controller is Dell’s next generation of controller with integrated redundant array of inde

Seite 4 - Notes, Notices, and Cautions

10 OverviewAbout RAIDRAID is a group of multiple independent physical disks that provide high performance by increasing the number of drives used for

Seite 5 - Contents

Overview 11Integrated MirroringWith Integrated Mirroring (RAID 1), data written to one disk is simultaneously written to another disk. If one disk fai

Seite 6 - 4 Contents

12 OverviewYD912bk1.book Page 12 Monday, April 2, 2007 4:39 PM

Seite 7

SAS 5/iR Features 13SAS 5/iR FeaturesThis section provides the specifications of Dell™ Serial-Attached SCSI (SAS) 5/iR controller. The following table

Seite 8 - 6 Contents

14 SAS 5/iR FeaturesHot add / Hot remove of end devices Yes YesSMART error support through management applicationsYes YesHardware-based RAID RAID 0, R

Seite 9 - CAUTION: Safety Instructions

Hardware Installation 15Hardware InstallationThis chapter describes how to install the Dell™ Serial-Attached SCSI (SAS) 5/iR Adapter. NOTE: The SAS 5

Seite 10 - 8 Safety Instructions

16 Hardware InstallationFigure 3-1. Installing a SAS 5/iR Adapter7Tighten the bracket screw, if any, or use the system’s retention clips to secure the

Seite 11 - Overview

Hardware Installation 17Figure 3-2. Connecting the Cable9Replace the cover of the system. See your system’s Hardware Owner’s Manual or the User’s Guid

Seite 12 - RAID Terminology

YD912bk1.book Page 2 Monday, April 2, 2007 4:39 PM

Seite 13 - Integrated Mirroring

18 Hardware InstallationYD912bk1.book Page 18 Monday, April 2, 2007 4:39 PM

Seite 14 - 12 Overview

Driver Installation 19Driver InstallationThe Dell™ Serial-Attached SCSI (SAS) 5/iR controller requires software drivers to operate with Microsoft® Win

Seite 15 - SAS 5/iR Features

20 Driver InstallationInstalling the Driver During Windows Operating System Installation NOTE: You do not need to install the driver on the Windows V

Seite 16 - 14 SAS 5/iR Features

Driver Installation 216On the Locate device driver screen, select Search for a suitable driver for my device and click Next.7Provide the appropriate d

Seite 17 - Hardware Installation

22 Driver InstallationInstalling From the Dell Operating System MediaUse the Operating System media CD or DVD that came with your Dell Precision works

Seite 18

Driver Installation 23Creating a Driver Update DisketteThe following files are needed before you create the DUD. NOTE: The SAS 5/iR driver package in

Seite 19

24 Driver InstallationInstalling the Driver Using an Update RPMThe following steps explain the installation procedure for the Red Hat Enterprise Linux

Seite 20 - 18 Hardware Installation

Driver Installation 25Perform the following steps to create the DUD using the DKMS tool.1Install the DKMS-enabled SAS 5/iR driver rpm package on a sys

Seite 21 - Driver Installation

26 Driver InstallationUpgrading the KernelIf you run the up2date utility to upgrade the kernel, the DKMS enabled driver packages must be reinstalled.

Seite 22 - Installation

SAS 5/iR BIOS 27SAS 5/iR BIOSThe BIOS of the Dell™ Serial-Attached SCSI (SAS) 5/iR controller (also known as CTRL-C) offers the following features:• S

Seite 23 - Driver Installation 21

www.dell.com | support.dell.comDell™ Serial-Attached SCSI 5/iRIntegrated and AdapterUser’s GuideYD912bk1.book Page 1 Monday, April 2, 2007 4:39 PM

Seite 24 - Creating a Driver Diskette

28 SAS 5/iR BIOSConfiguration UtilityStarting the Configuration Utility1Boot the system.2Press <Ctrl+C> during POST when prompted.If you wait to

Seite 25 - Installing the Driver

SAS 5/iR BIOS 29Integrated RAID Configuration and Management ScreensIntegrated RAID (IR) configuration and management involves many screens, all of wh

Seite 26

30 SAS 5/iR BIOSView Virtual DiskThe View Virtual Disk screen allows you to view the current virtual disk configuration.Press <Alt+N> to view th

Seite 27 - Driver Installation 25

SAS 5/iR BIOS 31Exit ScreenIt is important to exit the SAS BIOS Configuration Utility properly, because some changes take effect only when you exit. F

Seite 28 - Upgrading the Kernel

32 SAS 5/iR BIOS3Select Create IS Volume when you are prompted to create either an IS virtual disk or an IM virtual disk.The next screen shows a list

Seite 29 - SAS 5/iR BIOS

SAS 5/iR BIOS 335As disks are added, the Virtual Disk Size field will change to reflect the size of the new virtual disk. There are several limitation

Seite 30 - Configuration Utility

34 SAS 5/iR BIOSActivating a Virtual DiskA virtual disk can become inactive if, for example, it is removed from one SAS 5/iR controller and moved to a

Seite 31 - Create New Virtual Disk

Troubleshooting 35TroubleshootingTo get help with problems with your Dell™ Serial-Attached SCSI (SAS) 5/iR controller, you can Contact Dell or access

Seite 32 - Manage Virtual Disk

36 TroubleshootingPhysical Disk Related IssuesTable 6-2. Physical Disk IssuesProblem Suggested SolutionThe system does not boot from the SAS 5/iR cont

Seite 33 - Exit Screen

Troubleshooting 37Configuration Utility Error Messages NOTE: These error messages are displayed inside the Configuration Utility. Restart your system

Seite 34

Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates

Seite 35 - Synchronizing a Virtual Disk

38 TroubleshootingBIOS Error MessagesTable 6-4. BIOS Error MessagesMessage MeaningPress <Ctrl+C> to Enable BIOS When the BIOS is disabled, you a

Seite 36 - Deleting a Virtual Disk

Troubleshooting 39Device not available at Device may not be ready at this time. The device will be retried. If the problem persists, restart your syst

Seite 37 - Troubleshooting

40 TroubleshootingImage not found Could not locate the image for the Configuration Utility, its strings file, or its options file.Unable to load LSI C

Seite 38 - Physical Disk Related Issues

Updating the Firmware 41Updating the FirmwareFirmware updates to the Dell™ Serial-Attached SCSI (SAS) 5/iR controller is achieved by flashing the firm

Seite 39

42 Updating the FirmwareYD912bk1.book Page 42 Monday, April 2, 2007 4:39 PM

Seite 40 - BIOS Error Messages

Getting Help 43Getting HelpObtaining Assistance CAUTION: If you need to remove the computer cover, first disconnect the computer power and modem cabl

Seite 41

44 Getting HelpOnline ServicesYou can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORT page, and fill in the

Seite 42 - 40 Troubleshooting

Getting Help 45Dell Enterprise TrainingDell Enterprise training is available; see www.dell.com/training for more information. This service may not be

Seite 43 - Updating the Firmware

46 Getting HelpBefore You Call NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone syste

Seite 44 - 42 Updating the Firmware

Regulatory Notices 47Regulatory NoticesElectromagnetic Interference (EMI) is any signal or emission, radiated in free space or conducted along power o

Seite 45 - Getting Help

Contents 3ContentsCAUTION: Safety Instructions. . . . . . . . . . . . . . . . . . . . . 7SAFETY: General . . . . . . . . . . . . . . . . . . . . . .

Seite 46 - Online Services

48 Regulatory NoticesFCC Notices (U.S. Only)FCC, Class BThis equipment generates, uses, and can radiate radio frequency energy and, if not installed a

Seite 47 - Product Information

Regulatory Notice 49Industry Canada (Canada Only)Industry Canada, Class BThis Class B digital apparatus complies with Canadian NMB-003. NOTICE: The I

Seite 48 - Before You Call

50 Regulatory NoticesYD912bk1.book Page 50 Monday, April 2, 2007 4:39 PM

Seite 49 - Regulatory Notices

Regulatory Notice 51YD912bk1.book Page 51 Monday, April 2, 2007 4:39 PM

Seite 50 - FCC Notices (U.S. Only)

52 Regulatory NoticesYD912bk1.book Page 52 Monday, April 2, 2007 4:39 PM

Seite 51 - CE Notice (European Union)

Regulatory Notice 53YD912bk1.book Page 53 Monday, April 2, 2007 4:39 PM

Seite 52 - 50 Regulatory Notices

54 Regulatory NoticesYD912bk1.book Page 54 Monday, April 2, 2007 4:39 PM

Seite 53 - Regulatory Notice 51

Regulatory Notice 55Corporate Contact Details (Taiwan Only)Pursuant to Article 11 of the Commodity Inspection Act, Dell provides the following corpora

Seite 54 - 52 Regulatory Notices

56 Regulatory NoticesYD912bk1.book Page 56 Monday, April 2, 2007 4:39 PM

Seite 55 - Regulatory Notice 53

Regulatory Notice 57YD912bk1.book Page 57 Monday, April 2, 2007 4:39 PM

Seite 56 - 54 Regulatory Notices

4 ContentsInstalling the Red Hat Enterprise Linux Driver . . . . . . . . . . . . . . . . . 22Creating a Driver Diskette . . . . . . . . . . . . . .

Seite 57 - Regulatory Notice 55

58 Regulatory NoticesYD912bk1.book Page 58 Monday, April 2, 2007 4:39 PM

Seite 58 - 56 Regulatory Notices

Glossary 59GlossaryThis section defines or identifies technical terms, abbreviations, and acronyms used in this document.AAdapterAn adapter enables th

Seite 59 - Regulatory Notice 57

60 GlossaryDriverA device driver, often called a driver for short, is a program that allows the operating system or some other program to interface co

Seite 60 - 58 Regulatory Notices

Glossary 61OOperating SystemThe software that runs a computer, including scheduling tasks, managing storage, and handling communication with periphera

Seite 61 - Glossary

62 GlossaryRPMRPM, short for "Red Hat Package Manager" is a package management system primarily intended for Linux. RPM installs, updates, u

Seite 62

Glossary 63SMARTAcronym for Self-Monitoring Analysis and Reporting Technology. The self-monitoring analysis and reporting technology (SMART) feature m

Seite 63 - Glossary 61

64 GlossaryYD912bk1.book Page 64 Monday, April 2, 2007 4:39 PM

Seite 64

Index 65IndexBBIOS, 27Configuration Utility, 28fault code messages, 27POST messages, 27CConfiguration Utilityfunctions performed, 28navigating, 28over

Seite 65 - Glossary 63

66 Index66 IndexTtroubleshooting, 35BIOS boot order, 35BIOS error messages, 38Configuration Utility error messages, 37physical disk issues, 36WWindows

Seite 66 - 64 Glossary

Contents 56 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35BIOS Boot Order . . . . . . . . . . . . . . . . . . . . .

Seite 67 - Index 65

6 ContentsCE Notice (European Union) . . . . . . . . . . . . . . . . . . . . . . . . . . . 49European Union, Class B . . . . . . . . . . . . . . . .

Seite 68 - 66 Index

Safety Instructions 7 CAUTION: Safety InstructionsUse the following safety guidelines to help ensure your own personal safety and to help protect you

Kommentare zu diesen Handbüchern