10 Configuring 3.1 Target
Planning
If you are retaining the Target names in the new configuration, it is
recommended to record the Target names, location of .vhd files, and the
Target association of the .vhd files as displayed in Table 3-1 below.
Uninstalling the Current Target
To uninstall the current 3.0 Target that is configured in a clustered
environment:
1
Close all applications.
2
Disconnect all Initiators from Target(s). Perform this step from the Initiator.
From the client systems, disconnect all Initiators from the Target(s).
3
Open a Cluadmin interface and delete the previously created
Generic Service
from the cluster group.
4
Navigate to
Add or Remove programs
and uninstall the Microsoft iSCSI
Target from the passive node(s). Reboot each cluster node of the
PowerVault NX1950 storage solution.
Table 3-1. Target-Virtual Disk Matrix
Host 1 VHD File Name
Targe t 1 Fi le 1 :
File 2:
File 3:
Targe t 2
.
.
Targe t X Fi le 1 :
Seitenansicht 9