174 Web Tools Administrator’s Guide
53-1001772-01
Fabric Watch threshold configuration
13
DRAFT: BROCADE CONFIDENTIAL
Configuring threshold traits
Configure threshold traits to define a threshold for a particular class and area. You can configure
the following traits for a threshold:
Time Base—The time base (second, minute, hour, day) for the area
Low Boundary—The low threshold for the event-setting comparisons
High Boundary—The high threshold for the event-setting comparisons
Buffer Size—The size of the buffer zone used in event-setting comparisons
Use the following procedure to configure threshold traits.
1. Click Fabric Watch in the Manage section of the Tasks menu.
2. Select the Threshold Configuration tab.
3. Select the Trait Configuration subtab.
4. In Fabric Watch Explorer, select a class.
5. Under Area Selection, select an area from the list.
This sets the units in the Units field.
The module displays two columns of trait information, labeled System Default and Custom
Defined. You cannot modify the information in the System Default column.
6. In the Activate Level area:
Use the system default settings and proceed to step 11.
or
Click Custom Defined to specify new settings and proceed to the next step.
7. If necessary, select a time to record the event in the Time Base field.
8. Enter the lowest boundary of the normal zone in the Low Boundary field.
9. Enter the highest boundary of the normal zone in the High Boundary field.
10. Enter the size of the buffer zone in the Buffer Size field.
11. Click Apply.
Configuring threshold alarms
After you update the threshold information, use the Alarm Configuration subtab to customize the
notification settings for each event setting.
The alarm naming convention is modified for Port, E-Port, and F/FL class types:
Above” is called “High Above”
“Below” is called “Low Below”
“In Between” is called “High Below”
The Low Above action alarm supports all port class types for these options:
CRC errors
Invalid words
Protocol errors