Dell OpenManage Server Administrator Version 6.5 Betriebsanweisung Seite 228

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 250
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 227
228
System Event Log Messages for IPMI Systems
PS 1 Status: Power supply
sensor for PS 1, failure
was deasserted
Information This event is generated when the
power supply has recovered from
an earlier failure event.
PS 1 Status: Power supply
sensor for PS 1,
predictive failure was
asserted
Warning This event is generated when the
power supply is about to fail.
PS 1 Status: Power supply
sensor for PS 1,
predictive failure was
deasserted
Information This event is generated when the
power supply has recovered from
an earlier predictive failure event.
PS 1 Status: Power supply
sensor for PS 1, input
lost was asserted
Critical This event is generated when AC
power is removed from the power
supply.
PS 1 Status: Power supply
sensor for PS 1, input
lost was deasserted
Information This event is generated when the
power supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1,
configuration error was
asserted
Warn in g/
Critical
This event is generated when an
invalid power supply
configuration is detected.
PS 1 Status: Power supply
sensor for PS 1,
configuration error was
deasserted
Information This event is generated when the
power supply has recovered from
an earlier invalid configuration.
Table 4-5. Power Supply Events
(continued)
Event Message Severity Cause
Seitenansicht 227
1 2 ... 223 224 225 226 227 228 229 230 231 232 233 ... 249 250

Kommentare zu diesen Handbüchern