Dell OpenManage Server Administrator Version 6.5 Betriebsanweisung Seite 201

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 250
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 200
Storage Management Message Reference
201
2357 SAS expander
error: %1
Critical /
Failure / Error
Cause:
The %1
indicates a substitution
variable. The text for
this substitution
variable is generated by
the firmware and is
displayed with the alert
in the alert log. This
text can vary depending
on the situation.
Action:
There may be a
problem with the
enclosure. Check the
health of the enclosure
and its components by
selecting the enclosure
object in the tree view.
The Health subtab
displays a red
X
or
yellow exclamation
point for enclosure
components that are
Failed
or
Degraded
. See
the enclosure
documentation for
more information.
Clear Alert:
None
Related Alert:
None
LRA Number:
2061
754
2358 The battery
charge cycle is
complete.
OK / Normal /
Informational
Cause:
This alert is for
informational purposes.
Action:
None.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1151
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Seitenansicht 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 249 250

Kommentare zu diesen Handbüchern

Keine Kommentare