raid
Description Monitors, retrieves inventory, and configures the storage components connected to the
chassis.
NOTE: To use this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm raid get status
racadm raid get <Object type>
racadm raid get <Object type> -o
racadm raid get <Object type> -o -p <property names
separated by comma>
racadm raid get <Object type>:<FQDD's of Object type
separated by comma>
racadm raid set <Set Operation>:<FQDD of Object type>
racadm raid set <Set Operation> -pdkey:<FQDD of PD>
racadm raid set <Set Operation> -vdkey:<FQDD of VD>
Input
NOTE: Maximum property names that can be specified in –p option is 10.
NOTE: Maximum FQDDs that can be specified is 3.
(Object type) — controllers, vdisks, pdisks.
Set Operation
resetconfig
exportlog
forceonline
deletevd
blink
unblink
clearconfig
importconfig
ccheck
cancelcheck
patrolread
hotspare
init
assignva
createvd
–o — Displays all the properties of the selected Key or Object.
–p — Displays the property names with filter.
FQDD — Displays all the properties of the FQDD's Key.
Example
racadm raid get controllers
racadm raid get controllers -o
76