Dell OpenManage Server Administrator Version 7.0 Bedienungsanleitung Seite 157

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 302
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 156
omconfig: Managing Components Using the Instrumentation Service 157
Example Set Alert Action Commands
The following examples are valid example commands. For each successful
command issued, the following message is displayed:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event,
type:
omconfig system alertaction event=currentwarn
alert=false
or
omconfig servermodule alertaction event=
currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail
broadcast=true
or
omconfig servermodule alertaction event=
currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=
true
or
omconfig servermodule alertaction event=fanfail
alert=true
event=storagectrlbatteryfail Sets actions when a storage controller battery detects a
failure value.
NOTE: Event not available on Blade systems.
Table 4-23. Events for Which You Can Set Alert Actions
(continued)
Event Name Description
Seitenansicht 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 301 302

Kommentare zu diesen Handbüchern

Keine Kommentare