Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide
Introduction
Indicators, Messages, and Codes
Finding Software Solutions
Running the System Diagnostics
Troubleshooting Your System
Installing System Components
Installing Drives
Getting Help
Jumpers, Switches, and Connectors
I/O Connectors
Service-Only Parts Replacement Procedures
Notes, Notices, and Cautions
Abbreviations and Acronyms
For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.
Information in this document is subject to change without notice.
©2005DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, PowerVault, Dell OpenManage, Dimension, Inspiron, OptiPlex, Latitude, Dell Precision, PowerApp, PowerConnect, and DellNet
are trademarks of Dell Inc.; Intel is a registered trademark and Xeon is a trademark of Intel Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
Initial release: 28 Mar 2005
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Seitenansicht 0
1 2 3 4 5 6 ... 93 94

Inhaltsverzeichnis

Seite 1 - Abbreviations and Acronyms

Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Running

Seite 2 - System Board Jumpers

Back to Contents Page  Service-Only Parts Replacement Procedures Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Before You

Seite 3 - System Board Connectors

 Installing the Control Panel   1. Connect the control-panel cable to the control-panel assembly. See FigureC-1.  2. Lower the control-pane

Seite 4

 6. Remove the SCSI backplane. See "Removing the SCSI Backplane."  7. Remove the two screws and remove the fan interposer board. See F

Seite 5 - SCSI Backplane Connectors

 3. Remove all SCSI hard drives. See "Removing a SCSI Hard Drive" in "Installing Drives."  4. Remove the optical drive/disket

Seite 6

 Installing the SCSI Backplane   1. Install the SCSI backplane: a. Slowly lower the backplane into the system, being careful to avoid damaging

Seite 7 -  I/O Connectors

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See "Opening

Seite 8 - USB Connectors

 12. Place the two slide switches on each side of the chassis in the unlocked position to release the chassis crossbar, then lift up the crossbar a

Seite 9 - Network Cable Requirements

 15. Remove the RAID battery compartment: a. Gently pull the RAID battery compartment straight up. See FigureC-8. b. Lift the battery compar

Seite 10 - Control-Panel Assembly

 Installing the System Board   1. Transfer the RAID memory and RAID key (if present), processors, VRMs, and jumpers to the new system board. See

Seite 11 - Fan Interposer Board

l SCSI B data cable from the system board SCSI_B connector to the SCSI B backplane connector, if applicable  5. Install the heat sinks/processor fi

Seite 12 - SCSI Backplane

Back to Contents Page  Jumpers, Switches, and Connectors Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Jumpers—A General

Seite 13

 Installing the Power Distribution Board   1. Position the three alignment slots on the power distribution board with the three alignment tabs on

Seite 14 - System Board

 6. Disconnect the intrusion-switch cable from its system board connector. See FigureC-11.  7. Grasp the intrusion switch by its top and bottom

Seite 15

Back to Contents Page  Introduction Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Other Documents You May Need Your sys

Seite 16

Back to Contents Page  Indicators, Messages, and Codes Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Front-Panel Indicato

Seite 17

Table 2-2. Front-PanelLEDIndicators,Buttons,andConnectors Back-Panel Features and Indicators Figure2-2 shows the controls, indicators, and

Seite 18 - Installing the System Board

SCSI Hard-Drive Indicator Codes If RAID is activated, two indicators on each of the hard-drive carriers provide information on the status of the S

Seite 19 - Power Distribution Board

Power Indicator Codes The power button on the front panel controls the power input to the system's power supplies. The power indicator can prov

Seite 20 - Chassis Intrusion Switch

The LCD can display two lines of alphanumeric characters. The display codes are presented in two color combinations: l Blue background — Information

Seite 21

System Messages System messages appear on the screen during system boot to notify you of a possible problem with the system. Table2-8 lists the sys

Seite 22 -  Introduction

Drive not ready Diskette missing or improperly inserted in diskette drive. Reinsert or replace the diskette. Embedded RAID error An error has been gen

Seite 23 - System Status Indicators

Table A-1.SystemBoardJumperSettings System Board Connectors See FigureA-3 and TableA-2 for the location and description of the system boar

Seite 24

installed expansion card. "Troubleshooting Your System." PCIe Degraded Link Width Error: Embedded Bus#nn/Dev#nn/Funcn Expected Link Width is

Seite 25

System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the pr

Seite 26 - LCD Status Messages

Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, befo

Seite 27

Back to Contents Page  Finding Software Solutions Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Before You Begin Troub

Seite 28 - System Messages

Back to Contents Page  IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Available IRQ4 Serial port 1 (COM1 and COM3) IRQ5 Remote access

Seite 29

Back to Contents Page  Running the System Diagnostics Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Using Server Administ

Seite 30

 1. Create a set of diagnostics diskettes from the Dell OpenManage Server Assistant CD. See "Using the Dell OpenManage Server Assistant CD"

Seite 31 - System Beep Codes

Back to Contents Page 

Seite 32 - Alert Messages

Back to Contents Page  Troubleshooting Your System Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide  Safety First—For You

Seite 33

This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perf

Seite 34

Table A-2.SystemBoardConnectors Memory Riser Card Connectors See FigureA-4 for the location of the connectors on the memory riser card. Fi

Seite 35 - From the Utility Partition

 1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics." I

Seite 36

Troubleshooting a USB Device  Problem l System message indicates a problem with a USB device. l Device connected to a USB port is not operating p

Seite 37 - Back to Contents Page

RespondingtoaSystemsManagementSoftwareAlertMessage Systems management software monitors critical system voltages and temperatures, fans, and

Seite 38 - Checking the Equipment

 2. Unless you are installing a hot-plug component such as a cooling fan or hot-plug expansion card, turn off the system and attached peripherals,

Seite 39 - Troubleshooting the Mouse

 5. Reconnect the system to the electrical outlet, and turn on the system.  6. To replace the optional bezel, hook the right end of the bezel o

Seite 40 - Problem

l Expansion cards l Memory modules and memory riser cards l Processor(s) l Power supplies l Fans l Hard drives  3. Ensure that all cabl

Seite 41 - Troubleshooting a NIC

The power supply's fault indicator is lit. See "Power Indicator Codes" in "Indicators, Messages, and Codes."  3. Ensure that

Seite 42 - Opening the System

l Systems management software issues a memory-related message through the LCD display or systems management software.  Action  Memory-related bee

Seite 43 - Closing the System

 5. Close the system. See "Closing the System."  6. Reconnect the system to the electrical outlet, and turn on the system and attache

Seite 44

 13. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  14. Open the system. See "Opening

Seite 45

SCSI Backplane Connectors See FigureA-5 for the location and description of the connectors on the back of the SCSI backplane board. Figure A-5. Co

Seite 46

 1. Enter the System Setup program and ensure that the secondary SCSI channel is enabled and set to SCSI. See "Using the System Setup Program&

Seite 47

 3. If the integrated SCSI host adapter controls the SCSI hard drives, restart the system and press <Ctrl><a> to enter the SCSI configura

Seite 48

l Battery See "Activating the Optional Integrated RAID Controller" in "Installing Drives."  7. Close the system. See "Clos

Seite 49

Problem l Error message indicates a problem with an expansion card. l Expansion card performs incorrectly or not at all.  Action   1. Run the a

Seite 50

 1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

Seite 51

Back to Contents Page  Installing System Components Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide System Battery Fans

Seite 52

 6. Install the new system battery with the side labeled "+" facing up. See Figure6-1.  7. Install the new system battery. a. Supp

Seite 53

  1. Open the system. See "Opening the System" in "Troubleshooting Your System."  2. Compress the two latches on the top of

Seite 54

 Installing the Cooling Shroud  1. Align the four tabs on the sides of the shroud with the four slots on the chassis. See Figure6-4.  2. Slow

Seite 55 - System Battery

 Installing a Power Supply  1. Holding the lever in the open position, slide the new power supply into the chassis until the lever contacts the sy

Seite 56 - Removing a System Fan

10. Remove the expansion cards from expansion slots 6 and 7, if installed. See "Expansion Cards" in "Installing System Components."

Seite 57 - Cooling Shroud

 Hot-Plug Expansion Cards Your system supports PCI Express hot-plug expansion cards in slots 1, 3, 4, and 5 and one PCI-X hot-plug expansion card i

Seite 58 - Power Supplies

 4. Remove the filler bracket on the slot that you are using.  5. Insert the expansion card firmly into the expansion-card connector until the c

Seite 59 - Expansion Cards

 4. Open the plastic expansion-card retainer adjacent to the back of the empty slot. See Figure6-8.  5. Remove the filler bracket on the slot

Seite 60 - Hot-Plug Expansion Cards

 7. Close the expansion-card retainer.  8. Close the system. See "Closing the System" in "Troubleshooting Your System."  R

Seite 61

 5. Remove the filler bracket on the slot.  6. Insert the Fibre Channel module card firmly into the Fibre Channel module card connector until th

Seite 62 - Removing an Expansion Card

 8. Close the Fibre Channel module card retainer.  9. Close the system. See "Closing the System" in "Troubleshooting Your System.&

Seite 63

 Spare Bank Support If four identical single-rank memory modules are installed on a memory riser card, two of the four modules in the same rank can

Seite 64

 Removing and Installing a Hot-Pluggable Memory Riser Card The following procedure explains how to safely remove and install a hot-pluggable memory r

Seite 65 - System Memory

Table 6-4.MemoryRiserCardIndicatorsandFeatures Figure 6-13. Removing and Installing a Memory Riser Card  Removing and Installing a Non–

Seite 66 - Memory Mirroring Support

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See "Opening

Seite 67

Back to Contents Page  I/O Connectors Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Serial Connector Video Connector

Seite 68

6. Repeat step 2 through step 5 of this procedure to install the remaining memory modules. See Table6-2 and Table6-3 for sample memory configuration

Seite 69 - Installing Memory Modules

 5. If the heat sink has not separated from the processor, carefully rotate the heat sink in a clockwise, then counterclockwise, direction until it

Seite 70 - Processor

4. Unpack the new processor. If any of the pins on the processor appear bent, see "Getting Help."  5. If you are adding an additional pro

Seite 71 - Installing a Processor

See your User's Guide for instructions about using the System Setup program.  12. Run the system diagnostics to verify that the new processor op

Seite 72

Back to Contents Page  Installing Drives Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Installing SCSI Hard Drives Ins

Seite 73 - Installing A Processor VRM

 4. Insert the hard drive into the drive bay. See Figure7-2.  5. Close the hard-drive handle to lock the drive in place.  6. Replace the f

Seite 74 -  Installing Drives

 4. Remove the optical drive or optical drive filler plate from the carrier: a. Loosen the thumbscrew on the latch securing the optical drive or

Seite 75 - Removing a SCSI Hard Drive

The pins on the carrier fit into the corresponding holes in the side of the drive. See Figure7-4.  7. Replace the optical drive or optical drive fil

Seite 76

 10. Reconnect the system and peripherals to their electrical outlets. Connecting an External SCSI Tape Drive This subsection describes how to

Seite 77

 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  2. Open the system. See "Opening th

Seite 78 - Configuring the Boot Drive

Table B-2.SerialConnectorPinAssignments Video Connector You can attach a VGA-compatible monitor to the system's integrated video contro

Seite 79

 Reinstalling the SCSI Backplane Board  1. Install the backplane board. See Figure7-6. a. Slowly lower the backplane into the system, being ca

Seite 80

 2. Remove the cover. See "Opening the System."  3. Remove the memory filler blank or the memory riser card from memory slot C. See &

Seite 81

SCSI Hard-Drive Cabling Guidelines  Non-RAID Configurations For a system without an optional RAID controller installed, connect SCSI channel A on t

Seite 82 - RAID Configurations

Back to Contents Page  Getting Help Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Technical Assistance Dell Enterprise

Seite 83 -  Getting Help

support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific c

Seite 84 - Product Information

the system diagnostics.  4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diske

Seite 85 - Contacting Dell

Country (City) International Access Code Country Code City Code Department Name or Service Area, Website and E-Mail Address Area Codes, Local Numbers,

Seite 86

Canada (North York, Ontario) International Access Code: 011 Customer Care (Home Sales/Small Business) toll-free:1-800-847-4096 Customer Care (med./la

Seite 87

Finland (Helsinki) International Access Code: 990 Country Code: 358 City Code: 9 Website: support.euro.dell.com  E-mail: support.euro.dell.com/fi/fi

Seite 88

Ireland (Cherrywood) International Access Code: 16 Country Code: 353 City Code: 1 U.K. Technical Support (dial within U.K. only) 08709080800 Home Us

Seite 89

Figure B-4. USB Connector Pin Numbers Table B-4. USB Connector Pin Assignments Integrated NIC Connectors Each of the system's integrated NI

Seite 90

International Access Code: 00 Country Code: 352 Home/Small Business Sales (Brussels, Belgium) toll-free:080016884 Corporate Sales (Brussels, Belgium)

Seite 91

Country Code: 48 City Code: 22 Sales 5795999 Customer Service Fax 5795806 Reception Desk Fax 5795998 Switchboard 5795999 Portugal Internat

Seite 92

Sales 0859005185 Switzerland (Geneva) International Access Code: 00 Country Code: 41 City Code: 22 Website: support.euro.dell.com  E-mail: Tech_s

Seite 93

Back to Contents Page  Customer Service and Technical Support toll-free:1-800-456-3355 Employee Purchase Program (EPP) Customers toll-free:1-800-23

Seite 94 - Abbreviations and Acronyms

Back to Contents Page Dell™PowerEdge™6850SystemsInstallationandTroubleshootingGuide Notes, Notices, and Cautions Abbreviations and Acronym