e. Gently press the NVR Expansion Card into the riser card slot
until it is firmly in place and the card connectors extend
through the expansion slot.
f. Close the expansion card latch and reinstall the server
cover.
3. Connect power to the storage expansion.
4. Connect the storage expansion to the server.
a. Connect one end of the supplied Serial Attached SCSI
(SAS) cable to the storage expansion’s primary In port.
b. Connect the other end of the SAS cable to an available port
on the expansion card installed on the back of the server.
5. Turn on the storage expansion and the server.
6. In the Admin Tool, set up the Avigilon Control Center storage
configuration to include the storage expansion.
For more information, see Connecting the NVR Expansion that is
provided with the storage expansion.
Replacing Hard Drives
The hard drives on the server are set up in a Redundant Array of
Independent Disks (RAID) configuration. This allows information to be
recorded across several hard drives. If one hard drive fails, there is
enough information on the other hard drives for the server to continue
functioning. Only one hard drive can be replaced at a time while the
server is running.
If your server is still under warranty, contact Avigilon Technical Support to
replace a failed hard drive: http://avigilon.com/#/support-and-downloads/
If two or more hard drives fail at the same time, contact Avigilon Support
immediately for recovery instructions.
Important: Only replace a hard drive if the hard drive LED indicator and
the Server Administrator displays an error. See LED Indicators on
page 13 and Server Administrator on page 8 for more information.
1. Open the Server Administrator using an Administrator login.
2. In the System Tree on the left pane, select System > Storage >
Perc H710 Mini (Embedded) > Virtual Disks.
a. For the redundant virtual disk, select Check Consistency
from the drop down list and click Execute. Wait until the task
is done before continuing this procedure.