Dell OpenManageSNMP Reference Guide Version 7.2
Variables with Data Types of State Capabilities and State Capabilities Unique...567Dell Status Data Typ
Table 241. System Resource Memory Chassis IndexName systemResourceMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.500.40.1.1Description Defines
Syntax DellObjectRangeAccess Read-onlyTable 246. System Resource Memory Share DispositionName systemResourceMemoryShareDispositionObject ID 1.3.6.1
Access Not accessibleTable 251. System Resource Interrupt Table EntryName systemResourceInterruptTableEntryObject ID 1.3.6.1.4.1.674.10892.1.500.50.
Access Read-writeTable 256. System Resource Interrupt StatusName systemResourceInterruptStatusObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.5Descriptio
Table 261. System Resource Interrupt TriggerName systemResourceInterruptTriggerObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.10Description Defines the
Access Read-onlyTable 266. System Resource DMA State CapabilitiesName systemResourceDMAStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.3
Table 271. System Resource DMA Maximum Transfer SizeName systemResourceDMAMaximumTransferSizeObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.8Description
typeIsUnknown(2) The interface type is unknown.typeIsInternal(3) The interface type is internal.typeIsISA(4)The interface type is an Industry Standard
interruptIsLatched(2) The interrupt type is latched.Table 279. Resource Interrupt TriggerVariable Name: DellResourceInterruptTrigger Data Type: Intege
9Power GroupThe Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and am
1IntroductionThis reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is
Index powerUnitchassisIndex, powerUnitIndexTable 284. Power Unit Chassis IndexName powerUnitchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.1
Table 289. Power Supply Count for RedundancyName powerSupplyCountForRedundancyObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.6Description Defines the to
Table 294. Power Supply Chassis IndexName powerSupplychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.1Description Defines the index (one-base
Description Defines the maximum sustained output wattage of the power supply in tenths of watts.Syntax DellSigned32BitRangeAccess Read-onlyTable 30
Access Read-onlyTable 305. Power Supply Configuration Error TypeName powerSupplyConfigurationErrorTypeObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.12D
Index voltageProbechassisIndex, voltageProbeIndexTable 310. Voltage Probe Chassis IndexName voltageProbechassisIndexObject ID 1.3.6.1.4.1.674.10892.
Table 315. Voltage Probe ReadingName voltageProbeReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.6Description Defines the value of the voltage pro
Table 320. Voltage Probe Upper Noncritical ThresholdName voltageProbeUpperNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.11Descriptio
Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.When the value for voltageProbeType is other than voltageProbe
Access Read-onlyTable 330. Amperage Probe State CapabilitiesName amperageProbeStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.3Descripti
identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number>, where <MIB group number> is the MIB group number assigned to the MI
Access Read-onlyTable 334. Amperage Probe TypeName amperageProbeTypeObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.7Description Defines the type of the
Table 339. Amperage Probe Lower Noncritical ThresholdName amperageProbeLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.12Descript
AC Power Switch TableTable 344. AC Power Switch TableName aCPowerSwitchTableObject ID 1.3.6.1.4.1.674.10892.1.600.40Description Defines the AC Power
Syntax DellACPowerSwitchCapabilitiesAccess Read-onlyTable 349. AC Power Switch SettingsName aCPowerSwitchSettingsObject ID 1.3.6.1.4.1.674.10892.1.
Table 354. AC Power Switch StatusName aCPowerSwitchStatusObject ID 1.3.6.1.4.1.674.10892.1.600.40.1.9Description Defines the status of this AC power
Access Read-onlyTable 359. AC Power Cord State CapabilitiesName aCPowerCordStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.42.1.3Description
Battery TableTable 364. Battery TableName batteryTableObject ID 1.3.6.1.4.1.674.10892.1.600.50Description Defines the Battery Table.Syntax SEQUENCE
Table 369. Battery State SettingsName batteryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.4Description Defines the state settings of the
Table 374. Power Usage Table EntryName powerUsageTableEntryObject ID 1.3.6.1.4.1.674.10892.1.600.60.1Description Defines the Power Usage Table Entry
Table 379. Power Usage StatusName powerUsageStatusObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.5Description Defines the status of the power usage info
Section Topics MIB Group Numbers20 Cluster Group — defines variables for systems that operate as a cluster180021 Baseboard Management Controller Gro
Table 384. Power Usage Peak Watts Start Date NameName powerUsagePeakWattsStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.10Description Defin
Table 389. Power Usage Idle PowerName powerUsageIdlePowerObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.15Description Defines the system idle power (in
Table 394. Power Usage Instantaneous HeadroomName powerUsageInstantaneousHeadroomObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.20Description Defines th
Access Read-onlyTable 399. Power Profile IndexName powerProfileIndexObject ID 1.3.6.1.4.1.674.10892.1.600.70.1.2Description Defines the index (one-
Table 404. Power Profile Custom Memory Management CapabilitiesName powerProfileCustomMemoryManagementCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.60
unknown(1) The power supply’s capabilities are unknown.onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (onlin
powerSupplyTypeIsLinear(3) The power supply type is a linear power supply.powerSupplyTypeIsSwitching(4) The power supply type is a switching power sup
Table 413. Voltage Probe TypeVariable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1)
amperageProbeTypeIsOther(1) The amperage probe type is not one of the following:amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not
Table 417. AC Power Switch CapabilitiesVariable Name: DellACPowerSwitchCapabilities Data Type: IntegerPossible Data Values Meaning of Data Value unkn
Table 3. Server Administrator Field Replaceable Unit MIB Sections in This GuideSection Topic MIB Group Numbers22 Field Replaceable Unit Group — provid
onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online).notReadyCapable(4)The AC power cord’s capabilities are not ready.Tabl
Table 424. Power Cap SettingVariable Name: DellPowerCapSetting Data Type: IntegerPossible Data Values Meaning of Data Value disabled(0) Power cap is
NOTE: These values are bit masks, so combination values are possible.Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and pe
10Thermal GroupThe Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or
Syntax TableEntryAccess Read-onlyTable 432. Cooling Unit IndexName coolingUnitIndexObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.2Description Defines
Table 437. Cooling Unit NameName coolingUnitNameObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.7Description Defines the cooling unit name in this chassi
Access Read-onlyTable 442. Cooling Device IndexName coolingDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.2Description Defines the index of
Access Read-onlyTable 447. Cooling Device TypeName coolingDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.7Description Defines the cooling dev
Table 452. Cooling Device Lower Noncritical ThresholdName coolingDeviceLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.12Descript
Description Defines the probe capabilities of the cooling device.Syntax DellProbeCapabilitiesAccess Read-onlyTable 458. Cooling Device Discrete Rea
Dell Remote Access Controller Out-of-Band MIBThe Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that al
Access Read-onlyTable 462. Temperature Probe IndexName temperatureProbeIndexObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.2Description Defines the ind
Access Read-onlyTable 467. Temperature Probe TypeName temperatureProbeTypeObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.7Description Defines the tempe
Table 472. Temperature Probe Lower Noncritical ThresholdName temperatureProbeLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.12De
Thermal Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Table 477. Cooli
Table 479. Cooling Device Discrete ReadingVariable Name: DellCoolingDeviceDiscreteReading .Data Type: Integer Possible Data Values Meaning of Data Va
11User Security GroupThe User Security Table defines the objects that allow administrators to create and modify user accounts and to control which use
Table 485. User Security IndexName userSecurityIndexObject ID 1.3.6.1.4.1.674.10892.1.800.1.2Description Defines the user security index.Syntax Del
12Remote Flash BIOS GroupThe Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. T
Table 492. Remote Flash BIOS IndexName remoteFlashBIOSIndexObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.2Description Defines the index to the remote B
Table 497. Remote Flash BIOS Completion CodeName remoteFlashBIOSCompletionCodeObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.7Description Defines the co
to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator t
canceled(8) The remote flash BIOS has been canceled.pending(16) The remote flash BIOS update is pending.other(32) The remote flash BIOS state/setting
13Port GroupThe Port Group provides information about the different types of ports that may be present in your system. This management information bas
,pointingPortIndexTable 504. Pointing Port Chassis IndexNamepointingPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1Description Defines t
Access Read-onlyTable 509. Pointing Port Security StateNamepointingPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.10.6Description Defines the
Syntax IntegerKeyboardPortTableEntryAccess Not accessibleTable 514. Keyboard Port Table EntryName keyboardPortTableEntryObject ID 1.3.6.1.4.1.674.1089
Table 518. Keyboard Port State SettingsName keyboardPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4Description Defines the state and se
Table 523. Keyboard Port BIOS Connector TypeName keyboardPortBIOSConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9Description Defines the BIO
Description Defines the index of the processor ports in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 528. Processor Port State Capabilitie
Syntax DellProcessorPortConnectorType (See Processor Port Connector Types)Access Read-onlyTable 533. Processor Port NameNameprocessorPortNameObject ID
Table 537. Memory Device Port Chassis IndexNamememoryDevicePortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1Description Defines the index
,uUIDchassisIndexTable 10. UUID Chassis IndexName uUIDchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.1Description Defines the index (one-bas
Table 542. Memory Device Port Security StateNamememoryDevicePortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6Description Defines the secu
Table 547. Memory Device Port Physical Memory Card Index ReferenceNamememoryDevicePortPhysicalMemoryCardIndexReferenceObject ID 1.3.6.1.4.1.674.10892.
Table 551. Monitor Port IndexName monitorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2Description Defines the index of the monitor ports in t
Table 556. Monitor Port Connector TypeName monitorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7Description Defines the connector type
IndexsCSIPortchassisIndex,sCSIPortIndexTable 561. SCSI Port Chassis IndexNamesCSIPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1Descript
Syntax DellStatusAccess Read-onlyTable 566. SCSI Port Security StateNamesCSIPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6Description
Description Defines the Parallel Port Table.Syntax IntegerParallelPortTableEntryAccess Not accessibleTable 571. Parallel Port Table EntryNameparallelP
Table 575. Parallel Port State SettingsNameparallelPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4Description Defines the state and set
Table 580. Parallel Port Connector Pin OutNameparallelPortConnectorPinOutObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9Description Defines the pinout o
Serial Port TableTable 585. Serial PortNameserialPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.80Description Defines the Serial Port Table.Syntax In
1. BIOS Setup Control Group — This section explains the purpose of the MIB group and summarizes the major features of the component groups.2. BIOS Gro
Table 589. Serial Port State CapabilitiesNameserialPortStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3Description Defines the capabilit
Table 594. Serial Port NameNameserialPortNameObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8Description Defines the name of the serial port.Syntax DellS
Universal Serial Bus (USB) Port TableTable 599. Universal Serial Bus (USB) PortNameuSBPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.90Description De
Syntax DellStateCapabilitiesAccess Read-onlyTable 604. USB Port State SettingsNameuSBPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4Des
Access Read-onlyPort Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Tab
connectorPortTypeIsUnknown(2)The keyboard port connector type is unknown.connectorPortTypeIsMiniDIN(3)The keyboard port connector type is a mini DIN.c
connectorPortTypeIsSIMM(3)The memory device port connector type is a single in-line memory module (SIMM).connectorPortTypeIsSIP(4)The memory device po
connectorPortTypeIsDIN68pin(5)The SCSI port connector type is a DIN 68-pin.187
14Device GroupThe Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includ
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard.SNMP is a systems
Syntax PointingDeviceTableEntryAccess Not accessibleIndexpointingDevicechassisIndex,pointingDeviceIndexTable 617. Pointing Device Chassis IndexNamepoi
Syntax DellStatusAccess Read-onlyTable 622. Pointing Port Index ReferenceNamepointingPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6De
Access Not accessibleIndexkeyboardDevicechassisIndex,keyboardDeviceIndexTable 627. Keyboard Device Chassis IndexNamekeyboardDevicechassisIndexObject I
Access Read-onlyTable 632. Keyboard Port Index ReferenceNamekeyboardPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6Description Defines
IndexprocessorDevicechassisIndex,processorDeviceIndexTable 637. Processor Device Chassis IndexNameprocessorDevicechassisIndexObject ID 1.3.6.1.4.1.674
Table 642. Processor Port Index ReferenceNameprocessorPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6Description Defines the index to
Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown.Syntax DellUnsigned32
Syntax DellStringAccess Read-onlyTable 653. Processor Device Core CountNameprocessorDeviceCoreCountObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17Descr
Access Read-onlyTable 657. Processor Device Extended CapabilitiesNameprocessorDeviceExtendedCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21
Table 660. Processor Device Model NameNameprocessorDeviceModelNameObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24Description Defines the model of the p
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
INTERNET(1)MGMT(2)MIB(1)EXPERIMENTAL(3)PRIVATE(4)ENTERPRISES(1)DELL (674)SNMPv2(6)In the preceding example, the OID prefix for the Dell enterprise wou
Access Read-onlyTable 665. Processor Device Status IndexNameprocessorDeviceStatusIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2Description Defines
Table 670. Processor Device Status Location NameNameprocessorDeviceStatusLocationNameObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7Description Defines
Syntax DellObjectRangeAccess Read-onlyTable 675. Cache Device IndexNamecacheDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2Description Define
Table 680. Cache Device TypeNamecacheDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7Description Defines the type of cache device.Syntax DellCa
Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown.Syntax DellUnsigned32BitRang
Syntax DellCacheDeviceECCType (See Cache Device ECC Type)Access Read-onlyTable 691. Cache Device AssociativityNamecacheDeviceAssociativityObject ID 1.
Syntax MemoryDeviceTableEntryAccess Not accessibleIndexmemoryDevicechassisIndex,memoryDeviceIndexTable 696. Memory Device Chassis IndexNamememoryDevic
Syntax DellStatusAccess Read-onlyTable 701. Memory Device Memory Port Index ReferenceNamememoryDeviceMemoryPortIndexReferenceObject ID 1.3.6.1.4.1.674
Description Defines the bank location name of the memory device.Syntax DellStringAccess Read-onlyTable 706. Memory Device Type DetailsNamememoryDevice
Access Read-onlyTable 711. Memory Device Total Bus WidthNamememoryDeviceTotalBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16Description Defines
SNMP TrapsSNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management a
Table 715. Memory Device Failure ModesNamememoryDeviceFailureModesObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20Description Defines the failure modes
Table 720. Memory Device Speed NameNamememoryDeviceSpeedNameObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25Description This attribute defines the speed
IndexmemoryDeviceMappedAddresschassisIndex,memoryDeviceMappedAddressIndexTable 724. Memory Device Mapped Address Chassis IndexNamememoryDeviceMappedAd
Access Read-onlyTable 729. Memory Device Index ReferenceNamememoryDeviceIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6Description Defines
Access Read-onlyTable 734. Memory Device Mapped Address Ending AddressNamememoryDeviceMappedAddressEndingAddressObject ID 1.3.6.1.4.1.674.10892.1.1100
Description Defines the index of the generic device in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 739. Generic Device State Capabilities
Table 744. Generic Device NameNamegenericDeviceNameObject ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8Description Defines the name of the generic device.Syn
Access Read-onlyTable 749. PCI Device State CapabilitiesNamepCIDeviceStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3Description Defines
Table 754. PCI Device Manufacturer NameNamepCIDeviceManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8Description Defines the name of the P
Table 759. PCI Device Configuration Space Table EntryNamepCIDeviceConfigurationSpaceTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1Description D
22
Table 764. PCI Device Configuration Space StatusNamepCIDeviceConfigurationSpaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5Description Defines
Description Defines the common configuration space header of the PCI device.Syntax Octet String (SIZE(0.1025))Access Read-onlyNetwork Device TableTabl
Table 774. Network Device StatusNamenetworkDeviceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3Description Defines the status of the network devi
Description Defines the service name of the network device.Syntax DellStringAccess Read-onlyTable 780. Network Device Driver Image Path NameNamenetwor
Access Read-onlyTable 785. Network Device DHCP Server IP AddressNamenetworkDeviceDHCPServerIPAddressObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14Desc
Table 790. Network Device PCI Function NumberNamenetworkDevicePCIFunctionNumberObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19Description Defines the P
Description Defines if TOE is enabled for the network device.Syntax DellBooleanAccess Read-onlyTable 796. Network Device RDMA Capability FlagsNamenetw
Managed System Services Device TableTable 800. Managed System Services Device TableNameObject ID 1.3.6.1.4.1.674.10892.1.1100.100Description Defines t
Syntax DellStatusAccess Read-onlyTable 805. Managed System Services Device TypeNamemanagedSystemServicesDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.11
Syntax SdCardUnitTableEntryAccess Not accessibleIndexsdCardUnitChassisIndex,sdCardUnitIndexTable 810. SD Card Unit Chassis IndexNamesdCardUnitChassisI
2Dell OpenManage SNMP Version 7.2This section contains information added or updated for the current release.What’s New in This Release• Added support
Syntax DellStatusRedundancyAccess Read-onlyTable 815. SD Card Unit Count For RedundancyNamesdCardUnitCountForRedundancyObject ID 1.3.6.1.4.1.674.10892
Access Not accessibleIndexsdCardDeviceChassisIndex,sdCardDeviceIndexTable 820. SD Card Device Chassis IndexNamesdCardDeviceChassisIndexObject ID 1.3.6
Access Read-onlyTable 825. SD Card Device Config SettingsNamesdCardDeviceConfigSettingsObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6Description Defin
Table 830. SD Card Device Unit Index ReferenceNamesdCardDeviceUnitIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11Description Defines the
deviceTypeIsATouchPad(7)Device type is a touch pad.Table 834. Processor Device Status StateVariable Name:DellProcessorDeviceStatusStateData Type:Integ
deviceTypeIsMathProcessor(4)The processor device type is a math processor.deviceTypeIsDSP(5)The processor device type is a digital signal processor.de
processorUpgradeIsBySocket939(18)Upgrade is by Socket 939.processorUpgradeIsBySocketmPGA604(19)Upgrade is by Socket mPGA604.processorUpgradeIsBySocket
deviceFamilyIsPentiumPro(12)The processor family is Pentium Pro.deviceFamilyIsPentium2(13)The processor family is Pentium II.deviceFamilyIsPentiumMMX(
deviceFamilyIsPowerPC604(36) The processor family is Power PC 604.deviceFamilyIsPowerPC620(37) The processor family is Power PC 620.deviceFamilyIsPowe
deviceFamilyIsAMDOpteron6200 (61) The processor family is AMD Opteron 6200 Series Processor.deviceFamilyIsAMDOpteron4200 (62)The processor family is A
– Added the following tables for Trap on Traditional and Enhanced Varbinds.SNMP Traps: Traditional Varbinds: * alertSystem* alertTableIndexOID* alertM
deviceFamilyIsHobbit(112) The processor family is Hobbit.deviceFamilyIsCrusoe5000(120) The processor family is Crusoe 5000.deviceFamilyIsCrusoe3000(12
deviceFamilyIsPA-RISC8500(145)The processor family is PA-RISC 8500.deviceFamilyIsPA-RISC8000(146)The processor family is PA-RISC 8000.deviceFamilyIsPA
deviceFamilyIsQuadCoreIntelXeon7300(173)The processor family is Quad-Core Intel Xeon processor 7300 Series.deviceFamilyIsQuadCoreIntelXeon7400(174)The
deviceFamilyIsIntelCore2DuoMob ile(196)The processor family is Intel Core2 Duo mobile processor.deviceFamilyIsIntelCore2SoloMo bile(197)The processor
deviceFamilyIsQuadCoreIntelXeo n5xxx(219)The processor family is Quad-Core Intel Xeon processor 5xxx Series.deviceFamilyIsDualCoreIntelXeo n7xxx(221)T
Table 839. Cache Device TypeVariable Name:DellCacheDeviceTypeData Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)System cac
deviceWritePolicyIsDeterminedByIO(6)Device write policy is determined by I/O query.Table 842. Cache Device Status StateVariable Name:DellCacheDeviceSt
deviceAssociativityIsTwoWaySetAsso ciative(4)Device is two-way set associative.deviceAssociativityIsFourWaySetAsso ciative(5)Device is four-way set as
deviceSRAMTypeIsOther(1)Device SRAM type is not one of the following:deviceSRAMTypeIsUnknown(2)Device SRAM type is unknown.deviceSRAMTypeIsNonBurst(3)
deviceFormFactorIsSRIMM(14)Device form factor is SRIMM.deviceFormFactorIsFBDIMM(15) Device form factor is FB-DIMM.Table 848. Memory Device TypeVariabl
• Temperature Statistics Traps25
deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM.deviceTypeIsDDR3(24)Device type is DDR3.deviceTypeIsFBD2(25)Device type is FBD2.Table 849. Memo
Table 850. Generic Device TypeVariable Name:DellGenericDeviceTypeData Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)Device
connected(1)Media reports that device is connected.disconnected(2)Media reports that device is disconnected.driverBad(3)Driver cannot be opened to det
Table 855. Network Device RDMA Capability FlagsVariable Name:DellNetworkDeviceRDMACapabilityFlagsData Type:IntegerNOTE: These values are bit fields, s
Possible Data Values Meaning of Data Valueother(1)Device type is other.unknown(2)Device type is unknown.hypervisor(3)Device type is Hypervisor.vFlash(
standby(256)Device is in standby mode.Table 862. SD Card Device Card LicensedVariable Name:DellSDCardDeviceCardLicensedData Type:IntegerPossible Data
15Slot GroupThe Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also
Table 866. System Slot IndexName systemSlotIndexObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2Description Defines the index (one-based) of the system
Table 871. System Slot TypeName systemSlotTypeObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7Description Defines the type of the system slot.Syntax D
Table 876. System Slot Hot-Plug Bus WidthName systemSlotHotPlugBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12Description Defines the bus wid
systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent.systemSlotHotPlugCanSig
systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered).systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (c
systemSlotIsPCMCIA(7) .The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standardssystemSlotIsVLV
Table 882. System Slot UsageVariable Name: DellSystemSlotUsage Data Type: IntegerPossible Data Values Meaning of Data Value systemSlotUsageIsOther(1)
busWidthIs16bits(4) The system slot bus width is 16 bits.busWidthIs32bits(5) The system slot bus width is 32 bits.busWidthIs64bits(6) The system slot
266
16Memory GroupThe Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, l
Syntax PhysicalMemoryArrayTableEntryAccess Not accessibleTable 887. Physical Memory Array Table EntryNamephysicalMemoryArrayTableEntryObject ID 1.3.
Table 891. Physical Memory Array State SettingsName physicalMemoryArrayStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4Description Defines
3Instrumentation MIB Version GroupThe Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version
Table 896. Physical Memory Array Maximum SizeName physicalMemoryArrayMaximumSizeObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9Description Defines the
Table 901. Physical Memory Array ECC Error Noncritical ThresholdName physicalMemoryArrayECCErrorNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1
Table 905. Physical Memory Array Mapped Chassis IndexName physicalMemoryArrayMappedchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1Descripti
Table 910. Physical Memory Array Index ReferenceName physicalMemoryArrayIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6Description Defin
Description Defines the Physical Memory Configuration Table.Syntax SEQUENCE OF PhysicalMemoryConfigTableEntryAccess Not accessibleTable 915. Physic
Table 919. Physical Memory Configuration State SettingsName physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4Descriptio
Table 924. Physical Memory Configuration MOM SettingsName physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9Description D
Table 928. Physical Memory Logging IndexNamephysicalMemoryLoggingIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2Description Defines the index (one-
Access Not accessibleTable 933. Redundant Memory Unit Table EntryName redundantMemoryUnitTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1Descri
Table 937. Redundant Memory Unit State SettingsName redundantMemoryUnitStatesettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4Description Defines
Syntax DellUnsigned8BitRangeAccess Read-only28
Description Defines the Physical Memory Card Table.Syntax SEQUENCE OF PhysicalMemoryCardTableEntryAccess Not accessibleTable 942. Physical Memory C
Table 946. Physical Memory Card State SettingsName physicalMemoryCardStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4Description Defines t
Access Read-onlyTable 951. Physical Memory Card Physical Memory Array Index ReferenceName physicalMemoryCardPhyMemArrayIndexReferenceObject ID 1.3.6
Table 953. Physical Memory Array ECC Type DefinitionsVariable Name: DellPhysicalMemoryArrayECCTypeData Type: IntegerPossible Data Values Meaning of D
Table 956. Physical Memory Configuration Redundant CapabilitiesVariable Name: DellPhysicalMemoryConfigRedundantCapabilitiesData Type: IntegerPossible
Table 959. Physical Memory Logging SettingsVariable Name: DellPhysicalMemoryLoggingSettings Data Type: IntegerPossible Data Values Meaning of Data Va
17BIOS Setup Control GroupBasic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS perform
Access Not accessibleIndex biosSetUpControlchassisIndexTable 962. BIOS Setup Control Chassis IndexName biosSetUpControlchassisIndexObject ID 1.3.6.1.4
Access Read-onlyTable 967. BIOS Setup Control Numeric Lock Control CapabilitiesNamebSUCnumLockControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.140
4Systems Management Software GroupThe Systems Management Software Group allows users to see information about the standards and software that are supp
Access Read-onlyTable 972. BIOS Setup Control Processor Serial Number Control SettingsName bSUCprocessorSerialNumberControlSettingsObject ID 1.3.6.1
Access Read-onlyTable 977. BIOS Setup Control Speaker Control StatusName bSUCspeakerControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16Descr
Syntax DellStatusAccess Read-onlyTable 982. BIOS Setup Control NIF Wakeup on LAN Control NameName bSUCnIFwakeonLanControlNameObject ID 1.3.6.1.4.1.6
Syntax DellStringAccess Read-onlyTable 987. BIOS Setup Control Administrator Password Control Capabilities UniqueName bSUCadministratorPasswordContr
Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the cu
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user passw
SCSI Control TableTable 1001. SCSI Control TableName sCSIControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.20Description Defines the Small Computer
Syntax DellStateCapabilitiesAccess Read-onlyTable 1006. SCSI Control SettingsName sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4
Access Not accessibleIndex parallelPortControlchassisIndex,parallelPortControlIndexTable 1011. Parallel Port Control Chassis IndexName parallelPortCo
Access Read-onlyTable 1016. Parallel Port Control NameName parallelPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6Description Defines
ContentsNotes, Cautions, and Warnings...21 Introductio
Table 17. Systems Management Software Build NumberName systemManagementSoftwareBuildNumberObject ID 1.3.6.1.4.1.674.10892.1.100.3Description Defines
Index serialPortControlchassisIndex,serialPortControlIndexTable 1021. Serial Port Control Chassis IndexName serialPortControlchassisIndexObject ID 1.
Table 1026. Serial Port Control NameName serialPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6Description Defines the setup BIOS name o
Syntax DellObjectRangeAccess Read-onlyTable 1031. USB Control CapabilitiesName usbControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3D
Access Not accessibleTable 1036. IDE Control Table EntryName ideControlTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1Description Defines the
Access Read-onlyTable 1041. IDE Control StatusName ideControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5Description Defines the status for
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1046. Diskette Control IndexName disketteCont
Network Interface Control TableThese MIB objects enable you to track the attributes of the NIC card for your system.Table 1051. Network Interface Cont
Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control Capabilities)Access Read-onlyTable 1056. Network Interface Contr
Table 1060. BIOS Setting Table EntryName biosSettingTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1Description Defines the BIOS Setting Table
Table 1065. BIOS Setting Value TypeName biosSettingValueTypeObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5Description Defines the type of the BIOS set
Table 22. Systems Management Software URL NameName systemManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.10892.1.100.8Description Defines the uni
Description Defines the recommended display order of the BIOS setting within its BIOS setting group.Syntax DellUnsigned32BitRangeAccess Read-onlyTa
unknown(1) Speaker control state is unknown.enabled(2)Speaker control is enabled.low(4) Speaker control volume is low.medium(8) Speaker control volume
bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first.bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot fro
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.Table 1081. BIOS Password Control Setti
lpt2Capable(8) Setup BIOS can support parallel port 2.lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2.lpt3Capable(16) Setup BIOS can s
enableCapable(2)Setup BIOS can enable the serial port.com1Capable(4)Setup BIOS can support serial port 1.enableAndCom1Capable(6)Setup BIOS can enable
Table 1089. IDE Control CapabilitiesVariable Name: DellideControlCapabilitiesUnique Data Type: IntegerPossible Data Values Meaning of Data Valueunkno
integer(1) Value type is integer.string(2) Value type is string.enumeration(3) Value type is enumeration.orderedList(4) Value type is ordered list.317
318
18Local Response Agent GroupThe Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA).
Table 27. Systems Management Software Manufacturer NameName systemManagementSoftwareManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.100.13Descripti
Syntax LRAGlobalSettingsTableEntryAccess Not accessibleIndex lRAGlobalchassisIndexTable 1096. LRA Global Chassis IndexName lRAGlobalchassisIndexObje
Description Defines the set of thermal shutdown capabilities that are supported by the LRA.Syntax DellLRAThermalShutdownCapabilitiesUniqueAccess Re
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1105. LRA Action Table Action Number IndexNam
Syntax DisplayString (SIZE (0..256)Access Read-writeTable 1107. LRA Action Table Settings UniqueName lRAActionTableSettingsUniqueObject ID 1.3.6.1.
warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected.enableOnWarningCapable(6) The LRA enables ac
19Cost of Ownership GroupThe Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufactu
Syntax CooTableEntryAccess Not accessibleIndexcoochassisIndexTable 1113. COO Chassis IndexNamecoochassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.10
Syntax DellDateNameAccess Read-writeTable 1118. COO Acquisition Purchase OrderNamecooAquisitionPurchaseOrderObject ID 1.3.6.1.4.1.674.10892.1.1600.10.
Access Read-onlyTable 1123. COO Cost Center Information Vendor NameNamecooCostCenterInformationVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1
Access Read-writeTable 1128. COO Extended Warranty Provider NameNamecooExtendedWarrantyProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16Descr
5System State GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the
Access Read-writeTable 1133. COO Deployment Duration TypeNamecooDeploymentDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21Description Define
Access Read-writeTable 1138. COO Outsourcing Provider Fee NameNamecooOutsourcingProviderFeeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26Descripti
Access Read-writeTable 1143. COO Box Central Processing Unit (CPU) Serial Number NameNamecooBoxCPUSerialNumberNameObject ID 1.3.6.1.4.1.674.10892.1.16
Access Read-writeTable 1148. COO Depreciation Duration TypeNamecooDepreciationDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36Description De
Description Defines the COO Service Contract Table.Syntax SEQUENCE OF CooServiceContractTableEntryAccess Not accessibleTable 1153. COO Service Contrac
Table 1157. COO Service Contract Was RenewedNamecooServiceContractWasRenewedObject ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4Description Specifies whether
Syntax cooCostEventLogTableEntryAccess Not accessibleIndexcooCostEventLogchassisIndex,cooCostEventLogIndexTable 1162. COO Cost Event Log Chassis Index
Table 1166. COO Cost Event Log Duration TypeNamecooCostEventLogDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5Description Defines the durati
Table 1170. COO Warranty Chassis IndexNamecooWarrantychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1Description Defines the index (one-based
Table 1175. COO Warranty End Date NameNamecooWarrantyEndDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6Description Defines the warranty end date
• systemStateCoolingUnitStatusCombined• systemStateACPowerSwitchStatusCombined• systemStateRedundantMemoryUnitStatusCombined• systemStateProcessorDevi
Table 1179. COO Lease Information Chassis IndexNamecooLeaseInformationchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1Description Defines the
Table 1184. COO Lease Information Lease Rate FactorNamecooLeaseInformationLeaseRateFactorObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6Description Defi
Access Not accessibleTable 1189. COO Schedule Number Table EntryNamecooScheduleNumberTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1600.60.1Description
Description Defines the lease information index number to reference the schedule number.Syntax DellUnsigned32BitRangeAccess Read-writeTable 1194. COO
Access Read-onlyTable 1198. COO Options IndexName cooOptionsIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2Description Defines the index (one-based
Syntax SEQUENCE OF CooMaintenanceTableEntryAccess Not accessibleTable 1203. COO Maintenance Table EntryNamecooMaintenanceTableEntryObject ID 1.3.6.1.4
Table 1207. COO Maintenance Start Date NameNamecooMaintenanceStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4Description Defines the start d
Access Not accessibleTable 1212. COO Repair Table EntryNamecooRepairTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1600.90.1Description Defines the COO R
Description Defines the number of repairs that this system has undergone.Syntax DellCostofOwnershipStringAccess Read-writeTable 1217. COO Repair Vendo
Access Read-onlyTable 1221. COO Support Information IndexName cooSupportInformationIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2Description Defi
Description Defines the System State Table entry.Syntax SystemStateTableEntryAccess Not accessibleIndex systemStatechassisIndexTable 33. System Sta
Access Read-writeTable 1226. COO Support Information Fix Type NameName cooSupportInformationFixTypeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7D
Table 1230. COO Trouble Ticket IndexNamecooTroubleTicketIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2Description Defines the index (one-based) o
unknown(2)The ownership code is unknown.owned(3)The ownership code is owned.leased(4)The ownership code is leased.rented(5)The ownership code is rente
20Remote Access GroupThe Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to
Access Read-onlyTable 1241. Remote Access Adapter IndexNameremoteAccessAdapterIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2Description Defines th
Table 1246. Remote Access Product Info NameNameremoteAccessProductInfoNameObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7Description Defines the name of
Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware.Syntax IpAddressAccess Read-writeTab
Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware.Syntax IpAddressAccess Read-onlyT
• Remote SNMP Trap Table• Remote Dial-Up Table• Remote User Dial-In Configuration Table• Remote Dial-Out TableRemote Access TableThe following MIB obj
Table 1265. Remote Access TypeNameremoteAccessTypeObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3Description Defines the type of remote access hardware.
Table 37. System State Power Unit State DetailsName systemStatePowerUnitStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.5Description Defines
Description Defines the description of the product providing the remote access functionality.Syntax DellDisplayString (SIZE (0..255))Access Read-onlyT
Table 1276. Remote Access Local Area Network (LAN) CapabilitiesNameremoteAccessLANCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14Descriptio
Table 1281. Remote Access Out-of-Band SNMP SettingsNameremoteAccessOutOfBandSNMPSettingsObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19Description Defi
Table 1286. Remote Access Firmware Update Path NameNameremoteAccessFirmwareUpdatePathNameObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.24Description Def
Table 1291. Remote Access Miscellaneous Information NameNameremoteAccessMiscInfoNameObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29Description Defines
Remote User Administration TableTable 1296. Remote User Administration TableName remoteUserAdminTable Object ID 1.3.6.1.4.1.674.10892.1.1700.20Descrip
Table 1300. Remote User Admin User IndexName remoteUserAdminUserIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.20.1.3Description Defines the index (one-b
Description Defines the password for this remote access user.Syntax DisplayString (SIZE (0..255))Access Read-writeTable 1306. Remote User Admin User
Table 1311. Remote User Admin Alert Filter System CapabilitiesName remoteUserAdminAlertFilterSysCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1700.20.
Description Defines the protocol used by the alphanumeric pager provider for this remote access user.Syntax DellRemoteUserAdminAlphaProtocolType (Remo
Access Read-onlyTable 41. System State Power Supply Status CombinedName systemStatePowerSupplyStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10
Description Defines the password for the alphanumeric pager for this remote access user.Syntax DisplayString (SIZE (0..31))Access Read-writeTable 132
Access Read-onlyTable 1327. Remote User Admin Control SettingsName remoteUserAdminControlSettingsObject ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30Descri
Table 1331. Remote SNMP Trap Chassis IndexNameremoteSNMPTrapChassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.30.1.1Description Defines the index (on
Table 1336. Remote SNMP Trap StatusNameremoteSNMPTrapStatusObject ID 1.3.6.1.4.1.674.10892.1.1700.30.1.6Description Defines the status of this remote
Table 1341. Remote SNMP Trap Filter DRS CapabilitiesNameremoteSNMPTrapFilterDrsCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11Description D
Table 1346. Remote Dial-Up Table EntryNameremoteDialUpTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1700.40.1Description Defines the Remote Access Dial-
Syntax DellRemoteDialUpStateCapabilities (Remote Dial-Up State Capabilities)Access Read-onlyTable 1351. Remote Dial-Up State SettingsNameremoteDialUpS
Access Read-writeTable 1356. Remote Dial-Up Dial-Out Modem Connect Time-outNameremoteDialUpDialOutModemConnectTimeoutObject ID 1.3.6.1.4.1.674.10892.1
Remote User Dial-In Configuration TableTable 1361. Remote User Dial-In Configuration TableNameremoteUserDialInCfgTableObject ID 1.3.6.1.4.1.674.10892.
Table 1365. Remote User Dial-In Configuration User IndexNameremoteUserDialInCfgUserIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.50.1.3Description Defin
Table 45. System State Voltage Status DetailsName systemStateVoltageStatusDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.13Description Defines th
Description Defines the PPP password of this remote access dial-in user.Syntax DisplayString (SIZE (0..15))Access Read-writeTable 1371. Remote User Di
Access Read-onlyTable 1375. Remote Dial-Out Adapter IndexNameremoteDialOutAdapterIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2Description Defines
Table 1380. Remote Dial-Out IP AddressNameremoteDialOutIPAddressObject ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7Description Defines the IP address for th
remoteAccessTypeIsDRACIII(3)The remote access type is DRAC III.remoteAccessTypeIsERA(4)The remote access type is ERA.Table 1385. Remote Access Control
shutdown(64)The remote access hardware shuts down.Table 1387. Remote Access Monitor CapabilitiesVariable Name:DellRemoteAccessMonitorCapabilitiesData
nicDHCPCapable(4)The remote access hardware NIC can use DHCP to obtain an IP address.Table 1390. Remote Access LAN SettingsVariable Name:DellRemoteAcc
Table 1393. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) CapabilitiesVariable Name:DellRemoteAccessOutOfBandSNMPCapabilitiesDat
privilegeCapable(64)The admin user supports user privileges configuration.Table 1396. Remote User Admin State SettingsVariable Name:DellRemoteUserAdmi
emailTest(8)An e-mail test is performed for the admin user.Table 1399. Remote User Admin Alpha Protocol TypeVariable Name:DellRemoteUserAdminAlphaProt
unknown(1)The SNMP trap destination state settings are unknown.enabled(2)The SNMP trap destination is enabled.notReady(4)The SNMP trap destination is
Table 49. System State Cooling Unit State DetailsName statesystemStateCoolingUnitStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.17Description
dialInDHCPCapable(32)The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature.dialInAuthAnyCapable(64)The dial
remoteDialUpIsTone(3)The remote dial type is tone.remoteDialUpIsPulse(4)The remote dial type is pulse.Table 1408. Remote User Dial-In State Capabiliti
enableCapable(2)The dial-out destination can be disabled or enabled.notReadyCapable(4)The dial-out destination can be in the not ready state.dialOutPP
21Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher avail
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1415. Cluster IndexNameclusterIndexObject ID 1.3
Table 1420. Cluster Type Description NameNameclusterTypeDescriptionNameObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7Description Defines the descriptio
22Baseboard Management Controller GroupThe Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various
,bmcIndexTable 1425. BMC Chassis IndexNamebmcChassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1Description Defines the index (one-based) of the
Table 1430. BMC Display NameNamebmcDisplayNameObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6Description Defines the display name of the BMC.Syntax Dell
System State Table...
Access Read-onlyTable 53. System State Cooling Device Status CombinedName systemStateCoolingDeviceStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.20
Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems.Syntax DellStringAccess R
,bmcSerialInterfaceIndexTable 1440. BMC Serial Interface Chassis IndexNamebmcSerialInterfaceChassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1D
Table 1445. BMC Serial Interface StatusNamebmcSerialInterfaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6Description Defines the status of the
Description Defines the bit rate of the BMC serial interface.Syntax DellBMCSerialBitRateTypeAccess Read-onlyBaseboard Management Controller LAN Interf
Access Read-onlyTable 1455. BMC LAN Interface IndexNamebmcLANInterfaceIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3Description Defines the index
Table 1460. BMC LAN Interface IP Address SourceNamebmcLANInterfaceIPAddressSourceObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8Description Defines the
Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface.Syntax DisplayString (SIZE (0..32))Access Read-on
Table 1468. BMC Serial Flow Control TypeVariable Name:DellBMCSerialFlowControlTypeData Type:IntegerPossible Data Values Meaning of Data Value-- none(0
iDRAC6(10)Controller type is Integrated Dell Remote Access Controller 6.iDRAC6Modular(11)Controller type is Integrated Dell Remote Access Controller 6
23Field Replaceable Unit GroupA field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair
Syntax DellStatusAccess Read-onlyTable 57. System State Temperature Status DetailsName systemStateTemperatureStatusDetailslyObject ID 1.3.6.1.4.1.6
Table 1475. FRU IndexName fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2Description Defines the index (one-based) of the FRU.Syntax DellObj
Description Defines the serial number of the FRU.Syntax DisplayString (SIZE (0..64))Access Read-onlyTable 1481. FRU Part Number NameName fruPartNum
Possible Data Values Meaning of Data Value ok(1) FRU information is okay.notSupported(2) FRU information is not supported.notAvailable(3) FRU informa
24Storage Management GroupThe Storage Management Group is composed of the following:• Storage Management Group—information about the software product
Table 1488. Software ManufacturerName softwareManufacturerObject ID 1.3.6.1.4.1.674.10893.1.20.3Description Identifies the manufacturer of the Stora
Syntax DisplayStringAccess Read-onlyTable 1493. Agent VendorName agentVendorObject ID 1.3.6.1.4.1.674.10893.1.20.100.3Description Identifies the n
Table 1497. Agent Time StampName agentTimeStampObject ID 1.3.6.1.4.1.674.10893.1.20.110.3Description Identifies the last time that the agent values
Access Read-onlyTable 1502. Agent IP AddressName agentIPAddressObject ID 1.3.6.1.4.1.674.10893.1.20.110.8Description This entry is obsolete for Sto
Access Read-onlyTable 1507. Agent Global System StatusName agentGlobalSystemStatusObject ID 1.3.6.1.4.1.674.10893.1.20.110.13Description Global hea
Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.Possible values:1: Enabled2: Disabled3:
Syntax Octet String (Size(1..128)Access Read-onlyTable 61. System State Chassis Intrusion State DetailsName systemStateChassisIntrusionStateDetailsO
The following object sets up the Controller Table.Table 1510. Controller TableName controllerTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.1Descripti
Table 1514. Controller VendorName controllerVendorObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3Description Identifies the controller's (re)sel
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.Syntax IntegerAcces
Table 1521. Controller Physical Device CountName controllerPhysicalDeviceCountObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11Description Identifies
Table 1526. Controller Memory Size in BytesName controllerMemorySizeInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16Description Identifies the
Table 1531. Controller C0 Port 0 IDName controllerC0Port0IDObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21Description This entry is obsolete. Fibre
Table 1536. Controller C1 Port 0 World Wide NameName controllerC1Port0WWNObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26Description This entry is ob
Table 1541. Controller C1 Operating System ControllerName controllerC1OSControllerObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31Description This en
Table 1546. Controller Battery Charge CountName controllerBatteryChargeCountObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36Description This entry is
Description Durable unique ID for this controller.Syntax DisplayStringAccess Read-onlyTable 1550. Controller Alarm StateName controllerAlarmStateOb
Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power
99: Not ApplicableSyntax IntegerAccess Read-onlyTable 1554. Controller Minimum Firmware VersionName controllerMinFWVersionObject ID 1.3.6.1.4.1.674
Syntax IntegerAccess Read-writeTable 1559. Controller Patrol Read RateName controllerPatrolReadRateObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49D
1: Stopped - not running2: Ready - ready to start4: Active - is running8: Aborted - has abortedSyntax IntegerAccess Read-onlyTable 1564. Controller
Name controllerEncryptionKeyPresentObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58Description Indicates presence of encryption key for the controlle
Syntax IntegerAccess Read-writeTable 1572. Controller Encryption ModeName controllerEncryptionModeObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.63De
Table 1576. Controller Configured Drives SpinUp TimeName controllerConfiguredDrivesSpinUpTimeObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67Descripti
Access Not accessibleTable 1580. Channel EntryName channelEntryObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1Description Defines the channel table en
Access Read-onlyTable 1584. Channel SeverityName channelSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4Description This entry is obsolete fo
5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1588. Channel Component StatusName channelComponentStatusObject ID 1.3.6.1.4.1.
Possible values:1: SCSI2: IDE3: Fibre Channel4: Serial Storage Architecture (SSA)6: Universal Serial Bus (USB)7: SATA8: SAS9: PCIeSyntax IntegerAcces
Access Read-onlyTable 69. System State AC Power Cord Status DetailsName systemStateACPowerCordStatusDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.
Table 1595. Enclosure NameName enclosureNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2Description Identifies the enclosure's name as repres
Table 1599. Enclosure IDName enclosureIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6Description Represents unique id for an enclosure.Syntax Disp
Table 1604. Enclosure Split Bus Part NumberName enclosureSplitBusPartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11Description Identifies the
Table 1609. Enclosure TypeName enclosureTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16Description Indicates the type of the enclosure.Possible
Syntax IntegerAccess Read-onlyTable 1613. Enclosure AlarmName enclosureAlarmObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20Description Identifies
6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1617. Enclosure Component StatusName enclosureComponentStatusObject ID 1.3.6.1.4.1.674.108
Access Read-onlyTable 1621. Enclosure Part NumberName enclosurePartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28Description The part number
NOTE: A value of 9999 indicates that the feature is not available.Syntax IntegerAccess Read-onlyTable 1626. Enclosure Empty Slot CountName enclosure
Access Read-onlyTable 1630. Array Disk NameName arrayDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2Description Identifies the name of the a
39: Foreign40: Clear41: Unsupported53: Incompatible56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state.S
Access Read-onlyTable 73. System State Event Log StatusName systemStateEventLogStatusObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.41Description Defin
Table 1637. Array Disk Enclosure IDName arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9Description Identifies the SCSI ID of the
Access Read-onlyTable 1642. Array Disk Largest Contiguous Free Space in BytesNamearrayDiskLargestContiguousFreeSpaceInBytesObject ID 1.3.6.1.4.1.674
Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceIn
Table 1650. Array Disk Spare StateName arrayDiskSpareStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22Description Identifies the status of the ar
Syntax DellStatusAccess Read-onlyTable 1653. Array Disk Device NameName arrayDiskDeviceNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25Descripti
Syntax IntegerAccess Read-onlyTable 1658. Array Disk Capable SpeedName arrayDiskCapableSpeedObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30Descript
Table 1662. Array Disk Manufacture YearName arrayDiskManufactureYearObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34Description Indicates the four di
Syntax Octet StringAccess Read-onlyTable 1667. Array Disk Alta Revision IdName arrayDiskAltaRevisionIdObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined/NotApplicableSyntax Int
Syntax INTEGERAccess Read-onlyArray Disk Enclosure Connection TableThis table describes the connections among array disks, their enclosure, and thei
Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet str
Description Identifies the name of the array disk in this connection as represented in Storage Management.Syntax DisplayStringAccess Read-onlyTable
Table 1684. Array Disk Enclosure Connection Controller NumberName arrayDiskEnclosureConnectionControllerNumberObject ID 1.3.6.1.4.1.674.10893.1.20.13
Access Read-onlyTable 1688. Array Disk Channel Connection Array Disk NameName arrayDiskChannelConnectionArrayDiskNameObject ID 1.3.6.1.4.1.674.10893.
Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected.Syntax DisplayStringAcc
Syntax IntegerAccess Read-onlyTable 1697. Fan NameName Fan NameObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2Description Identifies the fan's n
Access Read-onlyTable 1701. Fan Probe UnitName fanProbeUnitObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6Description This entry is obsolete for Sto
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.Syntax DisplayStringAccess Read-onlyTabl
6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1710. Fan Component StatusName fanComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.7
Table 1713. Fan Connection TableNamefanConnectionTableObject ID fanConnectionTableDescription Defines the fan connection table.Syntax SEQUENCE OF FanC
Access Read-onlyTable 1718. Fan Connection Enclosure NameName fanConnectionEnclosureNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4Description I
Syntax Octet String (Size(1..128))Access Read-onlyTable 82. System State Processor Device Status CombinedName systemStateProcessorDeviceStatusCombin
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1723. Power Supply IndexName powerSupplyIndex
Access Read-onlyTable 1728. Power Supply TypeName powerSupplyTypeObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.7Description Defines the type of power
Table 1733. Power Supply Configuration Error TypeName powerSupplyConfigurationErrorTypeObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.12Description Defi
Syntax PowerSupplyConnectionEntryAccess Not accessibleIndex powerSupplyConnectionNumberTable 1738. Power Supply Connection NumberNamepowerSupplyConn
Table 1742. Power Supply Connection Enclosure NumberNamepowerSupplyConnectionEnclosureNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.5Descriptio
Table 1746. Temperature Probe Chassis IndexName temperatureProbechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.1Description Defines the inde
Description Defines the value of the temperature probe.When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the valu
Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold.Syntax DellSigned32BitRangeAccess Read-writeTabl
When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for t
Description Identifies the name of the temperature probe in this connection as represented in Storage Management.Syntax DisplayStringAccess Read-on
Table 86. System State SD Card Unit Status CombinedName systemStateSDCardUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.54Description
Syntax SEQUENCE OF EnclosureManagementModuleEntryAccess Not accessibleTable 1770. Enclosure Management Module EntryName EnclosureManagementModuleEnt
Description Identifies the current state of the enclosure management module.Possible states:0: Unknown1: Ready2: Failed3: Online4: Offline5: Not Inst
Table 1778. Enclosure Management Module Firmware VersionName enclosureManagementModuleFWVersionObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8Descript
5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1782. Enclosure Management Module Nexus IDName enclosureManagementModuleNexusIDO
Index enclosureManagementModuleConnectionNumberTable 1786. Enclosure Management Module Connection NumberName enclosureManagementModuleConnectionNumber
Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs.Syntax IntegerAccess
Description Defines the state capabilities of the battery.Syntax DellStateCapabilitiesAccess Read-onlyTable 1796. Battery State SettingsName batter
Table 1800. Battery Connection TableName batteryConnectionTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.16Description Defines the battery connection
Access Read-onlyTable 1805. Battery Connection Controller NameName batteryConnectionControllerNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4Des
Access Not accessibleTable 1809. Tape Drive NumberNametapeDriveNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1Description Instance number of th
6Chassis Information GroupThe Chassis Information Group objects provide information about the modular chassis in which a blade system resides.NOTE: Th
Access Read-onlyTable 1814. Tape Drive Bus TypeName tapeDriveBusTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6Description The bus type of the t
Table 1817. Virtual Disk TableName virtualDiskTableObject ID 1.3.6.1.4.1.674.10893.1.20.140.1Description Defines the virtual disk table.Syntax SEQUE
Access Read-onlyTable 1822. Virtual Disk StateNamevirtualDiskStateObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4Description Identifies the current st
Syntax IntegerAccess Read-onlyTable 1825. Virtual Disk Length in BytesName virtualDiskLengthBytesObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.7Desc
9: Not ApplicableSyntax IntegerAccess Read-onlyTable 1829. Virtual Disk Read PolicyName virtualDiskReadPolicyObject ID 1.3.6.1.4.1.674.10893.1.20.1
Table 1832. Virtual Disk Current Stripe Size in MegabytesName virtualDiskCurStripeSizeInMBObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.14Description
Syntax IntegerAccess Read-onlyTable 1837. Virtual Disk Roll-Up StatusName virtualDiskRollUpStatusObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19Des
Table 1840. Virtual Disk Array Disk TypeName virtualDiskArrayDiskTypeObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22Description Identifies the type
Table 1844. Virtual Disk Disk Cache PolicyName virtualDiskDiskCachePolicyObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26Description Indicates disk c
Table 1848. Array Disk Logical Connection Array Disk NameName arrayDiskLogicalConnectionArrayDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2De
10 Thermal Group...143Thermal Grou
Chassis Information Table EntryName chassisInformationTableEntryObject ID 1.3.6.1.4.1.674.10892.1.300.10.1Description Defines the chassis informatio
Table 1853. Array Disk Logical Connection Disk NumberName arrayDiskLogicalConnectionDiskNumberObject ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7Descripti
Syntax DisplayStringAccess Read-onlyTable 1858. Object OID EventName objectOIDEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.5Description MIB OID o
502
25Change Management GroupThe Change Management Group lets you monitor information about the Dell devices and software that are present on a particular
Table 1865. Device TableNamedeviceTableObject ID 1.3.6.1.4.1.674.10899.1.5Description Defines the Device Table.Syntax SEQUENCE OF DeviceEntryAccess No
Description Defines the ID for the vendor supplying the device.Syntax Octet StringAccess Read-onlyTable 1871. Device IDNamedeviceDeviceIDObject ID 1.3
Syntax Defines a table of application information for the system.Access Not accessibleTable 1875. Application EntryNameapplicationEntryObject ID 1.3.6
Table 1880. Application Display StringNameaplicationDisplayStringObject ID 1.3.6.1.4.1.674.10899.1.6.1.5Description A user visible display string that
508
26Dell Remote Access Controller Out-of-Band GroupThe Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Co
Chassis Parent Index ReferenceName chassisparentIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.4Description Defines the index (one-based)
Access Read-onlyTable 1886. DRsProductVersionNameDRsProductVersionObject ID 1.3.6.1.4.1.674.10892.2.1.1.5Description Defines the product version of a
Table 1891. DRsProductChassisNameNameDRsProductChassisNameObject ID 1.3.6.1.4.1.674.10892.2.1.1.10Description Defines the name of the chassis.Syntax D
Description Defines the firmware version of a chassis management controller.Syntax DellStringAccess Read-onlyChassis StatusThe following MIB tables pr
Table 1901. DRsRedCurrStatusNameDRsRedCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.4Description Defines the redundancy status being monitored by th
Table 1906. DRsCMCCurrStatusNameDRsCMCCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.9Description Defines the CMC health status being monitored by th
Table 1911. DRsIOMPrevStatusNameDRsIOMPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.2Description Defines the previous IOM subsystem status recorded
Table 1916. DRsBladePrevStatusNameDRsBladePrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.7Description Defines the previous blade subsystem health sta
Table 1921. DRsKVMChangeTimeNameDRsKVMChangeTimeObject ID 1.3.6.1.4.1.674.10892.2.3.3.3Description Defines the timestamp of the most recent iKVM statu
Description Defines the timestamp of the most recent temperature sensor health status change.Syntax TimeTicksAccess Read-onlyDRsCMCChangeTimeNameDRsCM
Table 1930. DRsCMC PSUTableEntryNameDrsCMCPSUTableEntryObject ID 1.3.6.1.4.1.674.10892.2.4.2.1Description Defines the CMC PSU table entry.Syntax DrsCM
Chassis Asset Tag NameName chassisAssetTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.10Description Defines the user-assigned asset tag name for
Table 1935. DRsPowerSurplusNameDRsPowerSurplusObject ID 1.3.6.1.4.1.674.10892.2.4.1.1.5Description Defines the power surplus (in Watts) remaining abov
Description Defines the chassis minimum power usage (in Watts) since last reset.Syntax DellPowerReadingAccess Read-onlyTable 1941. DRsWattsMinTimeName
Description Defines the index (one-based) of the associated chassis.Syntax DellCMCPowerIndexRangeAccess Read-onlyTable 1946. DRsPSUIndexNameDRsPSUInde
Table 1951. DRsPSUWattsReadingNameDRsPSUWattsReadingObject ID 1.3.6.1.4.1.674.10892.2.4.2.1.7Description Defines the instantaneous PSU Wattage reading
Table 1956. DrsCAMessageNameDrsCAMessageObject ID 1.3.6.1.4.1.674.10892.2.20.10.5Description Defines the CSSD message of the CMC Alert.Syntax DellStri
Table 1961. DRsAlertPreviousStatusNameDRsAlertPreviousStatusObject ID 1.3.6.1.4.1.674.10892.2.5000.10.5Description Previous status of object causing t
526
27SNMP TrapsSNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management
Table 1964. Table Index OIDVariable Name alertTableIndexOIDObject ID 1.3.6.1.4.1.674.10892.1.5000.10.2Description Specifies the object identifier fo
Syntax DisplayStringTable 1970. System FQDNVariable Name alertSystemFQDNObject ID 1.3.6.1.4.1.674.10892.4.5000.10.8Description Specifies fully qual
Chassis System NameName chassisSystemNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.15Description Defines the system name of this chassis.Syntax De
Description Line Item ExplanationChassis intrusion state: <Intrusion state>Specifies the chassis intrusion state (open or closed), for example:C
Description Line Item ExplanationPossible memory module event cause: <list of causes>Specifies a list of possible causes for the memory module e
RAC TrapsThis section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific t
TrapID Name Description Severity Category Cause Supported by RAC Platform1006 alertDrscPower OnThe RAC has detected a system power state change to pow
TrapID Name Description Severity Category Cause Supported by RAC Platformprobe has detected a warning value1014 alertDrscVolt Critical The RAC voltage
TrapID Description Severity262402 Generic Critical Fan Failure Critical262530 Generic Critical Fan Failure Cleared Information131330 Under-Voltage Pro
TrapID Description Severity356224 Chassis Intrusion (Physical Security Violation) Event ClearedInformation262400 Generic Predictive Fan Failure (predi
TrapID Description Severity487306 CPU Throttle Cleared (Normal Processor Speed)Information527106 Power Supply Redundancy Degraded Warning527105 Power
28Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the health of storage resources such as co
Chassis System User Phone Number NameName chassisSystemUserPhoneNumberNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.20Description Defines the user-
Table 1974. Storage Management Alert SeverityAlert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for
Trap VariablesThe Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditiona
Syntax DisplayStringAccess Read-onlyTable 1980. Object Nexus EventNameobjectNexusEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.6Description Durable, u
Description Hostname of object causing the alert if applicable.Syntax DisplayStringAccess Read-onlyTable 1985. Enhanced Service Tag EventNameserviceTa
544
29iDRAC7 MIBThe Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrate
SNMP Operations Supported SNMP versionGET, GETNEXT, GETBULK SNMP v1 , v2c and v3TRAP SNMP v1 and SNMP v2cNOTE: iDRAC7 does not support the SNMP SET o
Description This attribute defines the product name of a remote access card.Syntax StringTypeAccess Read-onlyTable 1988. RAC NameNameracShortNameObjec
Table 1993. RAC TypeNameracTypeObject ID 1.3.6.1.4.1.674.10892.5.1.1.7.0Description This attribute defines the type of a remote access card.Syntax Rac
Description This attribute defines the service tag of the system.Syntax StringTypeAccess Read-onlyTable 1998. System Express Service CodeNamesystemExp
Chassis LED Control Settings UniqueName chassisLEDControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.25Description Defines the readings
Table 2003. System Data Center NameNamesystemDataCenterNameObject ID 1.3.6.1.4.1.674.10892.5.1.3.8.0Description This attribute defines the Data Center
Description This attribute defines the system ID of the system.Syntax Unsigned16BitRangeAccess Read-onlyTable 2009. System OS VersionNamesystemOSVersi
Table 2013. Global System StatusNameglobalSystemStatusObject ID 1.3.6.1.4.1.674.10892.5.2.1.0Description This attribute defines the overall rollup sta
NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group.iDRAC7 TrapsThe iDRAC7 generates events that result
Syntax StringTypeTable 2019. Alert Current StatusVariable NamealertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.5.3.1.3.0Description Current status of
the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes.Syntax StringTypeTable 2025. Aler
TrapID Description Category SubCategory SeverityBattery Warning2226 Battery is low. System Health Battery Event MinorBattery Failure2225 Battery has f
TrapID Description Category SubCategory SeverityFiber Channel Warning2538 Fiber Channel warning. System Health Fiber Channel MinorFiber Channel Failur
TrapID Description Category SubCategory Severity2089 Network failure or critical event. System Health NIC Config CriticalTable 2036. Operation System
Table 2039. BIOS POST TrapTrapID Description Category SubCategory SeverityBios Post Failure2425 System BIOS detected a failure. System Health BIOS POS
Chassis Lock PresentName chassisLockPresentObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.30Description Specifies whether a chassis lock is present on t
Table 2043. Redundancy TrapsTrapID Description Category SubCategory SeverityRedundancy Information2475 Redundancy information. System Health Redundanc
TrapID Description Category SubCategory Severity2489 Integrated Dual SD Module redundancy is lost.System Health IDSDM RedundancyCriticalTable 2047. Se
TrapID Description Category SubCategory Severitylevel for a long enough period of time to be considered in a warning state.Temperature Statistics Fail
Storage Trap GroupThe Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in res
TrapID Description Category SubCategory Severity4202 Fan warning. Storage Fan Event MinorStorage Fan Failure4201 Fan failure. Storage Fan Event Critic
Table 2061. Temperature Probe TrapsTrapID Description Category SubCategory SeverityStorage Temperature Probe Information4211 Temperature probe informa
Table 2064. iDRAC IP Address Change TrapTrapID Description Category SubCategory SeverityiDRAC IP Address Change8499 iDRAC IP address has changed. Audi
30Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts across the information technology
unknownCapabilities(1)The object’s capabilities are unknown.enableCapable(2)The object can be disabled (offline, a binary 0 value) or enabled (online,
ok(3)The object’s status is OK.nonCritical(4)The object’s status is warning, noncritical.critical(5)The object’s status is critical (failure).nonRecov
Chassis Watchdog Control Expiry Time Capabilities UniqueName chassiswatchDogControlExpiryTimeCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.
The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significan
31SNMP Sample OutputThis appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the
'\02\02\02\02\02\02'1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 31.3.6.1.4.1.674.10892.1.200.10.1.25.1 ='\03\03\03\03\03\03'1.3.6.1.4.
1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 81.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 21.3.6.1.4.1.674.10892.1.
Syntax DellPowerButtonControlSettings (See Power Button Control Settings)Access Read-writeChassis Reseller NameName chassisResellerNameObject ID 1.
Access Read-onlyChassis NMI Button Control Settings UniqueName chassisNMIButtonControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.45Des
Managed System Services Device Table...227SD Card U
Access Read-onlyUUID TableThese objects comprise the server administrator definitions for the Universal Unique Identifier (UUID).Table 92. UUID Table
Table 96. UUID TypeName uUIDTypeObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.3Description Defines the type of the UUID for this chassis.Syntax DellUU
Table 100. POST Log Chassis IndexName postLogchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.1Description Defines the index (one-based) of th
Table 105. POST Log FormatName postLogFormatObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.5Description Defines format of the POST log.Syntax DellLogFo
Description Defines the record index of the event log.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 110. Event Log State Capabilities UniqueNa
Description Defines the severity of the event log record.Syntax DellStatusAccess Read-onlyStatus MandatoryTable 115. Event Log Date NameName event
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 119. System BIOS IndexName systemBIOSIndexObj
Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown.Syntax Dell
Table 128. System BIOS Manufacturer NameNamesystemBIOSManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.11Description Defines the system BIOS
Bit 19 EDD (Enhanced Disk Drive) Specification is supportedBit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is s
COO Cost Event Log Table...
Bit 1 USB Legacy is supportedBit 2 AGP is supportedBit 3 I2O boot is supportedBit 4 LS-120 boot is supportedBit 5 ATAPI ZIP Drive boot is supportedBit
Description Defines the Firmware Table entrySyntax FirmwareTableEntryAccess Not accessibleIndexfirmwarechassisIndex,firmwareIndexTable 134. Firmware C
Description Defines the status of the firmware.Syntax DellStateSettingsAccess Read-onlyTable 139. Firmware SizeNamefirmwareSizeObject ID 1.3.6.1.4.1.6
Access Read-onlyTable 144. Firmware Version NameNamefirmwareVersionNameObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.11Description Defines the version na
Table 148. Intrusion IndexNameintrusionIndexObject ID 1.3.6.1.4.1.674.10892.1.300.70.1.2Description Defines the index of the intrusion objects in this
Description Defines the type of the intrusion object.Syntax DellIntrusionTypeAccess Read-onlyTable 154. Intrusion Location NameNameintrusionLocationNa
Table 158. Baseboard IndexNamebaseBoardIndexObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.2Description Defines the index (one-based) of the base board.Sy
Description Defines the type of the baseboard.Syntax DellBaseBoardTypeAccess Read-onlyTable 164. Baseboard Type NameNamebaseBoardTypeNameObject ID 1.3
Table 169. Baseboard Service Tag NameNamebaseBoardServiceTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.13Description Defines the baseboard service
Table 174. Chassis TypeVariable Name : DellChassisTypeData Type: IntegerPossible Data Values Meaning of Data Valueother(1)The chassis type is not one
Global Data Group...
Possible Data Values Meaning of Data Valueunknown(2)The status of the chassis connection is unknown.ok(3)The status of the chassis connection is OK.fa
Possible Data Values Meaning of Data Valuenone(0)The hard drive has no fault LED capabilities.unknownCapabilities(1)The hard-drive fault LED capabilit
NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has ma
manualRebootWithoutOSShut downCapable(32)The operator can reboot without operating system shutdown.manualPowerOffWithOSShutd ownCapable(64)The operato
automaticNotificationCapable(4)Watchdog controls can be set to notify capable hostautomaticWatchDogTimerCapable(8)Watchdog controls can be set to func
enableCapable(2)The power button can be enabled (online) or disabled (offline).Table 189. Power Button Control SettingsVariable Name : DellPowerButton
Table 193. Baseboard TypeVariable Name : DellBaseBoardTypeData Type: IntegerPossible Data Values Meaning of Data Valueunknown(1)The baseboard type is
Data Type: IntegerPossible Data Values Meaning of Data Valueother(1)The firmware type is other than following values.unknown(2)The firmware type is un
boardIsHostingBoard(1)This baseboard is a hosting board.boardRequiresDaughterBoard (2)This baseboard requires at least one daughter board or auxiliary
7Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating system. Identifying informati
27 SNMP Traps...527Trap Variab
Access Read-onlyTable 201. Operating System Memory State SettingsName operatingSystemMemoryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.3
Table 206. Operating System Memory Available Page File SizeName operatingSystemMemoryAvailablePageFileSizeObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.
8System Resource GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system
Table 211. System Resource Map Chassis IndexName systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1Description Defines the i
Description Defines the type of this system map.Syntax DellSystemResourceMapType (System Resource Map Type)Access Read-onlySystem Resource Owner Ta
Table 221. System Resource Owner State CapabilitiesName systemResourceOwnerStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.20.1.3Description
Description Defines the description name of the system resource owner.Syntax DellStringAccess Read-onlyTable 227. System Resource Owner Interface I
Table 231. System Resource I/O Port IndexName systemResourceIOPortIndexObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.2Description Defines the index (on
Description Defines the share disposition of the system resource I/O port.Syntax DellResourceShareDisposition (Resource Share Disposition)Access Re
Kommentare zu diesen Handbüchern