www.dell.com | support.dell.comDell™ OpenManage™Server Administrator Version 5.4SNMP Reference Guide
10 ContentsCOO Support Information Table . . . . . . . . . . 420COO Trouble Ticket Table. . . . . . . . . . . . . . 422Cost of Ownership Variable V
100 Chassis Information GroupChassis Information Group Variable ValuesThis section includes definitions for server administrator-specific variable val
Chassis Information Group 101subNoteBook(14) The chassis type is a subnotebook.spaceSaving(15) The chassis type is a spacesaver.lunchBox(16) The chass
102 Chassis Information GroupTable 5-4. Fan Control CapabilitiesVariable Name: DellFanControlCapabilitiesData Type: IntegerPossible Data Values Meanin
Chassis Information Group 103Table 5-7. Hard-Drive Fault LED Control CapabilitiesVariable Name: DellHDFaultLEDControlCapabilitiesData Type: IntegerPos
104 Chassis Information GroupTable 5-9. Chassis Identification Control CapabilitiesVariable Name: DellChassisIdentifyControlCapabilitiesData Type: Int
Chassis Information Group 105identifyChassis(8)The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1.identi
106 Chassis Information GroupTable 5-12. Host Control SettingsVariable Name: DellHostControlSettingsNOTE: An operator can manually cause these actions
Chassis Information Group 107automaticWatchDogTimerCapable(8)Watchdog controls can be set to function automatically.automaticPowerOffCapable(16) Watch
108 Chassis Information GroupTable 5-15. Watchdog Timer CapabilitiesVariable Name: DellWatchDogTimerCapabilitiesData Type: IntegerPossible Data Values
Chassis Information Group 109Table 5-18. NMI Button Control CapabilitiesVariable Name: DellNMIButtonControlCapabilitiesData Type: IntegerPossible Data
Contents 11Baseboard Management Controller Group Variable Values . . . . . . . . . . . . . . . . . . . . . 49822 Field Replaceable Unit Group . . . .
110 Chassis Information GroupTable 5-21. Firmware TypeVariable Name: DellFirmwareTypeData Type: IntegerPossible Data Values Meaning of Data Valueother
Chassis Information Group 111rac(16) The firmware type is Remote Access Controller.iDRAC(17) The firmware type is Integrated Dell Remote Access Contro
112 Chassis Information GroupTable 5-23. Baseboard Feature FlagsVariable Name: DellBaseBoardFeatureFlagsData Type: IntegerPossible Data Values Meaning
Operating System Group 113Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating syst
114 Operating System GroupOperating System Chassis IndexOperating System State CapabilitiesOperating System State SettingsOperating System StatusName
Operating System Group 115Operating System Is PrimaryOperating System NameOperating System Version NameOperating System Memory TableName operatingSyst
116 Operating System GroupOperating System Memory Table EntryOperating System Memory Chassis IndexOperating System Memory State CapabilitiesOperating
Operating System Group 117Operating System Memory StatusOperating System Memory Total Physical SizeOperating System Memory Available Physical SizeOper
118 Operating System GroupOperating System Memory Available Page File SizeOperating System Memory Total Virtual SizeOperating System Memory Available
System Resource Group 119System Resource GroupThe Management Information Base (MIB) variables presented in this section enable you to track various at
12 ContentsLogical Devices Group . . . . . . . . . . . . . . . . . 604Virtual Disk Table. . . . . . . . . . . . . . . . . . 604Array Disk Logical C
120 System Resource GroupSystem Resource Map Table EntrySystem Resource Map Chassis IndexSystem Resource Map IndexSystem Resource Map State Capabiliti
System Resource Group 121System Resource Map State SettingsSystem Resource Map StatusSystem Resource Map TypeSystem Resource Owner TableName systemRes
122 System Resource GroupSystem Resource Owner Table EntrySystem Resource Owner Chassis IndexSystem Resource Owner IndexSystem Resource Owner State Ca
System Resource Group 123System Resource Owner State SettingsSystem Resource Owner StatusSystem Resource Owner Interface TypeSystem Resource Map Index
124 System Resource GroupSystem Resource Owner Description NameSystem Resource Owner Interface InstanceSystem Resource Input/Output (I/O) Port TableSy
System Resource Group 125System Resource I/O Port Chassis IndexSystem Resource I/O Port IndexSystem Resource I/O Port State CapabilitiesSystem Resourc
126 System Resource GroupSystem Resource I/O Port StatusSystem Resource I/O Port Owner Index ReferenceSystem Resource I/O Port Share DispositionSystem
System Resource Group 127System Resource I/O Port Ending AddressSystem Resource Memory TableSystem Resource Memory Table EntrySystem Resource Memory C
128 System Resource GroupSystem Resource Memory IndexSystem Resource Memory State CapabilitiesSystem Resource Memory State SettingsSystem Resource Mem
System Resource Group 129System Resource Memory Owner Index ReferenceSystem Resource Memory Share DispositionSystem Resource Memory Starting AddressSy
Contents 13Voltage Probe Traps . . . . . . . . . . . . . . . . 642Amperage Probe Traps. . . . . . . . . . . . . . . 644Chassis Intrusion Traps . .
130 System Resource GroupSystem Resource Memory FlagsSystem Resource Interrupt TableSystem Resource Interrupt Table EntrySystem Resource Interrupt Cha
System Resource Group 131System Resource Interrupt IndexSystem Resource Interrupt State CapabilitiesSystem Resource Interrupt State SettingsSystem Res
132 System Resource GroupSystem Resource Interrupt Owner Index ReferenceSystem Resource Interrupt Owner Share DispositionSystem Resource Interrupt Lev
System Resource Group 133System Resource Interrupt TriggerSystem Resource Direct Memory Access (DMA) TableSystem Resource DMA Table EntrySystem Resour
134 System Resource GroupSystem Resource DMA IndexSystem Resource DMA State CapabilitiesSystem Resource DMA State SettingsSystem Resource DMA StatusNa
System Resource Group 135System Resource DMA Owner Index ReferenceSystem Resource DMA Share DispositionSystem Resource DMA Maximum Transfer SizeSystem
136 System Resource GroupSystem Resource DMA Bus MasterSystem Resource Group Variable ValuesThis section includes definitions for server administrator
System Resource Group 137typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus.typeIsMCA(6) The interface type is
138 System Resource GroupTable 7-5. Resource Interrupt TypeVariable Name: DellResourceInterruptTypeData Type: IntegerPossible Data Values Meaning of D
System Resource Group 139Table 7-8. Resource DMA Transfer WidthVariable Name: DellResourceDMATransferWidthData Type: IntegerPossible Data Values Meani
14 ContentsA Standard Data Type Definitions . . . . . . 677Common Data Types . . . . . . . . . . . . . . . . . . . 677Variables with Data Types of
140 System Resource Group
Power Group 141Power GroupThe Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and
142 Power GroupPower Unit Table EntryPower Unit Chassis IndexPower Unit IndexPower Unit State CapabilitiesName powerUnitTableEntry Object ID 1.3.6.1.4
Power Group 143Power Unit State SettingsPower Unit Redundancy StatusPower Supply Count for RedundancyPower Unit NameName powerUnitStateSettings Object
144 Power GroupPower Unit StatusPower Supply TablePower Supply Table EntryPower Supply Chassis IndexName powerUnitStatusObject ID 1.3.6.1.4.1.674.1089
Power Group 145Power Supply IndexPower Supply State Capabilities UniquePower Supply State Settings UniquePower Supply StatusName powerSupplyIndexObjec
146 Power GroupPower Supply Output WattsPower Supply TypePower Supply Location NamePower Supply Input VoltageName powerSupplyOutputWattsObject ID 1.3.
Power Group 147Power Supply Power Unit Index ReferencePower Supply Sensor StatePower Supply Configuration Error TypePower Supply Power Monitor Capable
148 Power GroupVoltage Probe TableVoltage Probe Table EntryVoltage Probe Chassis IndexVoltage Probe IndexName voltageProbeTable Object ID 1.3.6.1.4.1.
Power Group 149Voltage Probe State CapabilitiesVoltage Probe State SettingsVoltage Probe StatusVoltage Probe ReadingName voltageProbeStateCapabilities
Introduction 15IntroductionThis introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide," ex
150 Power GroupVoltage Probe TypeVoltage Probe Location NameVoltage Probe Upper Nonrecoverable ThresholdVoltage Probe Upper Critical ThresholdName vol
Power Group 151Voltage Probe Upper Noncritical ThresholdVoltage Probe Lower Noncritical ThresholdVoltage Probe Lower Critical ThresholdVoltage Probe L
152 Power GroupVoltage Probe Probe CapabilitiesVoltage Probe Discrete ReadingAmperage Probe TableName voltageProbeProbeCapabilitiesObject ID 1.3.6.1.4
Power Group 153Amperage Probe Table EntryAmperage Probe Chassis IndexAmperage Probe IndexAmperage Probe State CapabilitiesName amperageProbeTableEntry
154 Power GroupAmperage Probe State SettingsAmperage Probe StatusAmperage Probe ReadingName amperageProbeStateSettingsObject ID 1.3.6.1.4.1.674.10892.
Power Group 155Amperage Probe TypeAmperage Probe Location NameWhen the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperage
156 Power GroupAmperage Probe Upper Nonrecoverable ThresholdAmperage Probe Upper Critical ThresholdAmperage Probe Upper Noncritical ThresholdAmperage
Power Group 157Amperage Probe Lower Critical ThresholdAmperage Probe Lower Nonrecoverable ThresholdAmperage Probe Probe CapabilitiesName amperageProbe
158 Power GroupAmperage Probe Discrete ReadingAC Power Switch TableAC Power Switch Table EntryName amperageProbeDiscreteReadingObject ID 1.3.6.1.4.1.6
Power Group 159AC Power Switch Chassis IndexAC Power Switch IndexAC Power Switch CapabilitiesAC Power Switch SettingsName aCPowerSwitchChassisIndexObj
16 Introduction• Added the values to the DellAmperageProbeType enumeration:– amperageProbeTypeIsPowerSupplyAmps(23)– amperageProbeTypeIsPowerSupplyWat
160 Power GroupAC Power Switch Redundancy StatusAC Power Cord Count for RedundancyAC Power Switch NameAC Power Switch Redundancy ModeName aCPowerSwitc
Power Group 161AC Power Switch StatusAC Power Cord TableAC Power Cord Table EntryAC Power Cord Chassis IndexName aCPowerSwitchStatusObject ID 1.3.6.1.
162 Power GroupAC Power Cord IndexAC Power Cord State CapabilitiesAC Power Cord State SettingsAC Power Cord StatusName aCPowerCordIndexObject ID 1.3.6
Power Group 163AC Power Cord AC Power Switch Index ReferenceAC Power Cord Location NameBattery TableBattery Table EntryName aCPowerCordaCPowerSwitchIn
164 Power GroupBattery Chassis IndexBattery IndexBattery State CapabilitiesBattery State SettingsName batteryChassisIndexObject ID 1.3.6.1.4.1.674.108
Power Group 165Battery StatusBattery ReadingBattery Location NamePower Usage TableName batteryStatusObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.5Descri
166 Power GroupPower Usage Table EntryPower Usage Chassis IndexPower Usage IndexPower Usage State CapabilitiesName powerUsageTableEntryObject ID 1.3.6
Power Group 167Power Usage State SettingsPower Usage StatusPower Usage Entity NamePower Usage Cumulative WattageName powerUsageStateSettingsObject ID
168 Power GroupPower Usage Cumulative Wattage Start Date NamePower Usage Peak WattsPower Usage Peak Watts Start Date NameName powerUsageCumulativeWatt
Power Group 169Power Usage Peak Watts Reading Date NamePower Usage Peak AmpsPower Usage Peak Amps Start Date NameName powerUsagePeakWattsReadingDateNa
Introduction 17What's New in the Change Management MIBNo changes.Introduction to the SNMP Reference GuideThis reference guide provides a formatte
170 Power GroupPower Usage Peak Amps Reading Date NamePower Group Variable ValuesThis section includes definitions for server administrator-specific v
Power Group 171onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working.powerSupplyIsON(16) The power supply is i
172 Power GrouppowerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a
Power Group 173acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range.configurationError(64) The power supply senso
174 Power GroupvoltageProbeTypeIs3Point3Volt(4)The voltage probe type is a 3.3-V probe.voltageProbeTypeIs5Volt(5) The voltage probe type is a 5-V prob
Power Group 175Table 8-7. Voltage Probe Discrete ReadingVariable Name: DellVoltageDiscreteReadingData Type: IntegerPossible Data Values Meaning of Dat
176 Power GroupamperageProbeTypeIsFLEA(11) The amperage probe type is a FLEA (standby) amperage probe.amperageProbeTypeIsBattery(12) The amperage prob
Power Group 177Table 8-9. Amperage Probe Discrete ReadingVariable Name: DellAmperageDiscreteReadingData Type: IntegerPossible Data Values Meaning of D
178 Power GroupinputSourceCord1Return(4) Input source is AC power cord 1, with return.inputSourceCord2NoReturn(8) Input source is AC power cord 2, wit
Power Group 179Table 8-14. AC Power Cord State SettingsVariable Name: DellACPowerCordStateSettingsData Type: IntegerPossible Data Values Meaning of Da
18 IntroductionServer Administrator Instrumentation MIBThe Server Administrator Instrumentation MIB (filename 10892.mib) provides instrumentation data
180 Power Group
Thermal Group 181Thermal GroupThe Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are s
182 Thermal GroupCooling Unit Chassis IndexCooling Unit IndexCooling Unit State CapabilitiesCooling Unit State SettingsName coolingUnitchassisIndex Ob
Thermal Group 183Cooling Unit Redundancy StatusCooling Device Count For RedundancyCooling Unit NameCooling Unit StatusName coolingUnitRedundancyStatus
184 Thermal GroupCooling Device TableCooling Device Table EntryCooling Device Chassis IndexCooling Device Index Name coolingDeviceTable Object ID 1.3.
Thermal Group 185Cooling Device State CapabilitiesCooling Device State SettingsCooling Device StatusName coolingDeviceStateCapabilitiesObject ID 1.3.6
186 Thermal GroupCooling Device ReadingCooling Device TypeCooling Device Location NameName coolingDeviceReadingObject ID 1.3.6.1.4.1.674.10892.1.700.1
Thermal Group 187Cooling Device Upper Nonrecoverable ThresholdCooling Device Upper Critical ThresholdCooling Device Upper Noncritical ThresholdCooling
188 Thermal GroupCooling Device Lower Critical ThresholdCooling Device Lower Nonrecoverable ThresholdCooling Device Cooling Unit Index ReferenceCoolin
Thermal Group 189Cooling Device Probe CapabilitiesCooling Device Discrete ReadingTemperature Probe TableName coolingDeviceProbeCapabilitiesObject ID 1
Introduction 195 Chassis Information Group — defines chassis types, events, and indicators3006 Operating System Group — defines variables for name, ve
190 Thermal GroupTemperature Probe Table EntryTemperature Probe Chassis IndexTemperature Probe Index Temperature Probe State CapabilitiesName temperat
Thermal Group 191Temperature Probe State SettingsTemperature Probe StatusTemperature Probe ReadingName temperatureProbeStateSettings Object ID 1.3.6.1
192 Thermal GroupTemperature Probe TypeTemperature Probe Location NameTemperature Probe Upper Nonrecoverable ThresholdTemperature Probe Upper Critical
Thermal Group 193Temperature Probe Upper Noncritical ThresholdTemperature Probe Lower Noncritical ThresholdTemperature Probe Lower Critical ThresholdT
194 Thermal GroupTemperature Probe Probe CapabilitiesTemperature Probe Discrete ReadingName temperatureProbeProbeCapabilitiesObject ID 1.3.6.1.4.1.674
Thermal Group 195Thermal Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section
196 Thermal GroupTable 9-2. Cooling Device SubtypeVariable Name: DellCoolingDeviceSubTypeData Type: IntegerPossible Data Values Meaning of Data Valuec
Thermal Group 197Table 9-4. Temperature Probe TypeVariable Name: DellTemperatureProbeTypeData Type: IntegerPossible Data Values Meaning of Data Valuet
198 Thermal Group
User Security Group 199User Security GroupThe User Security Table defines the objects that allow administrators to create and modify user accounts and
Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either pot
20 IntroductionServer Administrator Remote Access MIBThe Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information ab
200 User Security GroupUser Security Chassis IndexUser Security IndexUser Security User NameUser Security Control NameName userSecuritychassisIndex Ob
User Security Group 201User Security Request NameName userSecurityRequestNameObject ID 1.3.6.1.4.1.674.10892.1.800.1.5Description Defines a request na
202 User Security Group
Remote Flash BIOS Group 203Remote Flash BIOS GroupThe Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely updat
204 Remote Flash BIOS GroupRemote Flash BIOS Chassis IndexRemote Flash BIOS IndexRemote Flash BIOS State Capabilities UniqueRemote Flash BIOS State Se
Remote Flash BIOS Group 205Remote Flash BIOS StatusRemote Flash BIOS Last BIOS Date NameRemote Flash BIOS Completion CodeRemote Flash BIOS Minimum Con
206 Remote Flash BIOS GroupRemote Flash BIOS Variable ValuesThis section includes definitions for server administrator-specific variable values used i
Remote Flash BIOS Group 207Table 11-3. Remote Flash BIOS Completion CodeVariable Name: DellRemoteFlashBIOSCompletionCodeData Type: IntegerPossible Dat
208 Remote Flash BIOS Group
Port Group 209Port GroupThe Port Group provides information about the different types of ports that may be present in your system. This management inf
Introduction 21Server Administrator Baseboard Management Controller, ASF MIBThe Server Administrator BMC MIB (filename DcAsfSrv.mib) provides informat
210 Port GroupPointing Port Table EntryPointing Port Chassis IndexPointing Port IndexPointing Port State CapabilitiesName pointingPortTableEntryObject
Port Group 211Pointing Port State SettingsPointing Port StatusPointing Port Security StatePointing Port Connector TypeName pointingPortStateSettingsOb
212 Port GroupPointing Port NamePointing Port BIOS Connector TypeKeyboard Port TableKeyboard Port Table EntryName pointingPortName Object ID 1.3.6.1.4
Port Group 213Keyboard Port Chassis IndexKeyboard Port IndexKeyboard Port State CapabilitiesKeyboard Port State SettingsName keyboardPortchassisIndexO
214 Port GroupKeyboard Port StatusKeyboard Port Security StateKeyboard Port Connector TypeKeyboard Port NameName keyboardPortStatusObject ID 1.3.6.1.4
Port Group 215Keyboard Port BIOS Connector TypeProcessor Port TableProcessor Port Table EntryProcessor Port Chassis IndexName keyboardPortBIOSConnecto
216 Port GroupProcessor Port IndexProcessor Port State CapabilitiesProcessor Port State SettingsProcessor Port StatusName processorPortIndexObject ID
Port Group 217Processor Port Security StateProcessor Port Connector TypeProcessor Port NameProcessor Port BIOS Connector TypeName processorPortSecurit
218 Port GroupMemory Device Port TableMemory Device Port Table EntryMemory Device Port Chassis IndexMemory Device Port IndexName memoryDevicePortTable
Port Group 219Memory Device Port State CapabilitiesMemory Device Port State SettingsMemory Device Port StatusMemory Device Port Security StateName mem
22 IntroductionServer Administrator Storage Management MIBThe Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage man
220 Port GroupMemory Device Port Connector TypeMemory Device Port NameMemory Device Port BIOS Connector TypeMemory Device Port Physical Memory Array I
Port Group 221Memory Device Port Physical Memory Card Index ReferenceMonitor Port TableMonitor Port Table EntryMonitor Port Chassis IndexName memoryDe
222 Port GroupMonitor Port IndexMonitor Port State CapabilitiesMonitor Port State SettingsMonitor Port StatusName monitorPortIndexObject ID 1.3.6.1.4.
Port Group 223Monitor Port Security StateMonitor Port Connector TypeMonitor Port NameMonitor Port BIOS Connector TypeName monitorPortSecurityState Obj
224 Port GroupSmall Computer System Interface (SCSI) Port TableSCSI Port Table EntrySCSI Port Chassis IndexSCSI Port IndexName sCSIPortTableObject ID
Port Group 225SCSI Port State CapabilitiesSCSI Port State SettingsSCSI Port StatusSCSI Port Security StateName sCSIPortStateCapabilities Object ID 1.3
226 Port GroupSCSI Port Connector TypeSCSI Port NameSCSI Port BIOS Connector TypeParallel Port TableName sCSIPortConnectorType Object ID 1.3.6.1.4.1.6
Port Group 227Parallel Port Table EntryParallel Port Chassis IndexParallel Port IndexParallel Port State CapabilitiesName parallelPortTableEntryObject
228 Port GroupParallel Port State SettingsParallel Port StatusParallel Port Security StateParallel Port Connector TypeName parallelPortStateSettingsOb
Port Group 229Parallel Port NameParallel Port Connector Pin OutParallel Port Capabilities UniqueParallel Port Base I/O AddressName parallelPortNameObj
Introduction 23Server Administrator Change Management MIBThe Server Administrator Change Management MIB (filename dellcm.mib) provides management data
230 Port GroupParallel Port IRQ LevelParallel Port DMA SupportSerial Port TableSerial Port Table EntryName parallelPortIRQLevelObject ID 1.3.6.1.4.1.6
Port Group 231Serial Port Chassis IndexSerial Port IndexSerial Port State CapabilitiesSerial Port State SettingsName serialPortchassisIndexObject ID 1
232 Port GroupSerial Port StatusSerial Port Security StateSerial Port Connector TypeSerial Port NameName serialPortStatus Object ID 1.3.6.1.4.1.674.10
Port Group 233Serial Port Maximum SpeedSerial Port Capabilities UniqueSerial Port Base I/O AddressSerial Port IRQ LevelName serialPortMaximumSpeedObje
234 Port GroupUniversal Serial Bus (USB) Port TableUSB Port Table EntryUSB Port Chassis IndexUSB Port IndexName uSBPortTableObject ID 1.3.6.1.4.1.674.
Port Group 235USB Port State CapabilitiesUSB Port State SettingsUSB Port StatusUSB Port Security StateName uSBPortStateCapabilities Object ID 1.3.6.1.
236 Port GroupUSB Port Connector TypeUSB Port NameUSB Port BIOS Connector TypeName uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7D
Port Group 237Port Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Table
238 Port GroupTable 12-2. Keyboard Port Connector TypesVariable Name: DellKeyboardPortConnectorTypeData Type: IntegerPossible Data Values Meaning of D
Port Group 239Table 12-3. Processor Port Connector TypesVariable Name: DellProcessorPortConnectorTypeData Type: IntegerPossible Data Values Meaning of
24 IntroductionSNMP Basic TerminologyIt is important to have a good understanding of the key technical terms used in this guide. This guide provides d
240 Port GroupTable 12-4. Memory Device Port Connector TypesVariable Name: DellMemoryDevicePortConnectorTypeData Type: IntegerPossible Data Value Mean
Port Group 241connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM).connectorPortTypeIsSODIMM(13)
242 Port GroupTable 12-6. SCSI Port Connector TypesVariable Name: DellSCSIPortConnectorTypeData Type: IntegerPossible Data Values Meaning of Data Valu
Device Group 243Device GroupThe Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and periphera
244 Device GroupPointing Device Table EntryPointing Device Chassis IndexPointing Device IndexPointing Device State CapabilitiesName pointingDeviceTabl
Device Group 245Pointing Device State SettingsPointing Device StatusPointing Port Index ReferencePointing Device TypeName pointingDeviceStateSettingsO
246 Device GroupPointing Device Number of ButtonsKeyboard Device TableKeyboard Device Table EntryKeyboard Device Chassis IndexName pointingDeviceNumbe
Device Group 247Keyboard Device IndexKeyboard Device State CapabilitiesKeyboard Device State SettingsKeyboard Device StatusName keyboardDeviceIndexObj
248 Device GroupKeyboard Port Index ReferenceKeyboard Device Type NameKeyboard Device Layout NameProcessor Device TableName keyboardPortIndexReference
Device Group 249Processor Device Table EntryProcessor Device Chassis IndexProcessor Device IndexProcessor Device State CapabilitiesName processorDevic
Introduction 25Managed ObjectA managed object is any item in a computer system that can be singled out for discovery, monitoring, or user intervention
250 Device GroupProcessor Device State SettingsProcessor Device StatusProcessor Port Index ReferenceProcessor Device TypeName processorDeviceStateSett
Device Group 251Processor Device Manufacturer NameProcessor Device Status StateProcessor Device FamilyProcessor Device Maximum SpeedName processorDevi
252 Device GroupProcessor Device Current SpeedProcessor Device External Clock SpeedProcessor Device VoltageName processorDeviceCurrentSpeedObject ID 1
Device Group 253Processor Device Upgrade InformationProcessor Device Version NameProcessor Device Core CountProcessor Device Core Enabled CountName pr
254 Device GroupProcessor Device Thread CountProcessor Device CharacteristicsName processorDeviceThreadCountObject ID 1.3.6.1.4.1.674.10892.1.1100.30.
Device Group 255Processor Device Extended CapabilitiesProcessor Device Extended SettingsName processorDeviceExtendedCapabilitiesObject ID 1.3.6.1.4.1.
256 Device GroupProcessor Device Brand NameProcessor Device Model NameProcessor Device Stepping NameProcessor Device Status TableName processorDeviceB
Device Group 257Processor Device Status Table EntryProcessor Device Status Chassis IndexProcessor Device Status IndexName processorDeviceStatusTableEn
258 Device GroupProcessor Device Status State CapabilitiesProcessor Device Status State SettingsProcessor Device Status StatusProcessor Device Status
Device Group 259Processor Device Status Location NameProcessor Device Status Port Index ReferenceCache Device TableCache Device Table EntryName proces
26 IntroductionName is the exact string by which the variable is known in the MIB. MIB variables are named according to the following conventions: • V
260 Device GroupCache Device Chassis IndexCache Device IndexCache Device State CapabilitiesCache Device State SettingsName cacheDevicechassisIndexObje
Device Group 261Cache Device StatusCache Device Processor Device Index ReferenceCache Device TypeCache Device LocationName cacheDeviceStatusObject ID
262 Device GroupCache Device Status StateCache Device External Socket NameCache Device LevelCache Device Maximum SizeName cacheDeviceStatusStateObject
Device Group 263Cache Device Current SizeCache Device SpeedCache Device Write PolicyCache Device Is SocketedName cacheDeviceCurrentSizeObject ID 1.3.6
264 Device GroupCache Device Error Checking and Correction (ECC) TypeCache Device AssociativityCache Device Supported TypeCache Device Current TypeNam
Device Group 265Memory Device TableMemory Device Table EntryMemory Device Chassis IndexMemory Device IndexName memoryDeviceTableObject ID 1.3.6.1.4.1.
266 Device GroupMemory Device State CapabilitiesMemory Device State SettingsMemory Device StatusMemory Device Memory Port Index ReferenceName memoryDe
Device Group 267Memory Device TypeMemory Device Location NameMemory Device Error Count NOTE: Memory Device Failure Modes has now replaced this attrib
268 Device GroupMemory Device Bank Location NameMemory Device Type DetailsMemory Device Form FactorMemory Device SetName memoryDeviceBankLocationNameO
Device Group 269Memory Device SizeMemory Device SpeedMemory Device Total Bus WidthMemory Device Total Data Bus WidthName memoryDeviceSizeObject ID 1.3
Introduction 27Frequently Used Terms in Variable NamesThe following terms are frequently used in the name of a MIB variable:Capability refers to the a
270 Device GroupMemory Device Correctable Memory Event Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Correct
Device Group 271Memory Device Failure ModesMemory Device Manufacturer NameMemory Device Part Number NameMemory Device Serial Number NameName memoryDev
272 Device GroupMemory Device Asset Tag NameMemory Device Speed NameMemory Device Mapped Address TableMemory Device Mapped Address Table EntryName mem
Device Group 273Memory Device Mapped Address Chassis IndexMemory Device Mapped Address IndexMemory Device Mapped Address State CapabilitiesMemory Devi
274 Device GroupMemory Device Mapped Address StatusMemory Device Index ReferenceMemory Device Mapped Address Row PositionMemory Device Mapped Address
Device Group 275Memory Device Mapped Address Interleave DepthMemory Device Mapped Address Starting AddressMemory Device Mapped Address Ending AddressG
276 Device GroupGeneric Device Table EntryGeneric Device Chassis IndexGeneric Device IndexGeneric Device State CapabilitiesName genericDeviceTableEntr
Device Group 277Generic Device State SettingsGeneric Device StatusGeneric Device System Slot Index Reference Generic Device TypeName genericDeviceStat
278 Device GroupGeneric Device NamePCI Device TablePCI Device Table EntryPCI Device Chassis IndexName genericDeviceNameObject ID 1.3.6.1.4.1.674.10892
Device Group 279PCI Device IndexPCI Device State CapabilitiesPCI Device State SettingsPCI Device StatusName pCIDeviceIndexObject ID 1.3.6.1.4.1.674.10
28 IntroductionThe following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example
280 Device GroupPCI Device System Slot Index ReferencePCI Device Data Bus WidthPCI Device Manufacturer NamePCI Device Description NameName pCIDeviceSy
Device Group 281PCI Device SpeedPCI Device Adapter FaultPCI Device Configuration Space TablePCI Device Configuration Space Table EntryName pCIDeviceSp
282 Device GroupPCI Device Configuration Space Chassis IndexPCI Device Configuration Space IndexPCI Device Configuration Space State CapabilitiesPCI D
Device Group 283PCI Device Configuration Space StatusPCI Device Index ReferencePCI Device Configuration Space Bus NumberPCI Device Configuration Space
284 Device GroupPCI Device Configuration Space Function NumberPCI Device Configuration Space HeaderNetwork Device TableNetwork Device Table EntryName
Device Group 285Network Device Chassis IndexNetwork Device IndexNetwork Device StatusNetwork Device Connection StatusName networkDeviceChassisIndexObj
286 Device GroupNetwork Device Description Name Network Device Product NameNetwork Device Vendor NameNetwork Device Service NameName networkDeviceDesc
Device Group 287Network Device Driver Image Path NameNetwork Device Driver Version NameNetwork Device IP AddressNetwork Device IP Subnet MaskName netw
288 Device GroupNetwork Device Default Gateway IP AddressNetwork Device DHCP Server IP AddressNetwork Device Current MAC AddressNetwork Device Permane
Device Group 289Network Device PCI Bus NumberNetwork Device PCI Device NumberNetwork Device PCI Function NumberNetwork Device IRQName networkDevicePCI
Introduction 29UUID IndexUUID TypeUUID ValueReference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administ
290 Device GroupNetwork Device Base IO Port AddressNetwork Device Teaming FlagsNetwork Device TOE Capability FlagsNetwork Device TOE EnabledName netwo
Device Group 291Network Device RDMA Capability FlagsNetwork Device RDMA EnabledNetwork Device iSCSI Capability FlagsNetwork Device iSCSI EnabledName n
292 Device GroupDevice Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.T
Device Group 293Table 13-3. Processor Device Status ReadingVariable Name: DellProcessorDeviceStatusReadingData Type: IntegerNOTE: These values are bit
294 Device GroupTable 13-5. Processor Upgrade InformationVariable Name: DellProcessorUpgradeInformationData Type: IntegerPossible Data Values Meaning
Device Group 295processorUpgradeIsBySocket939(18) Upgrade is by Socket 939.processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604.processo
296 Device GroupdeviceFamilyIsPentium2(13) The processor family is Pentium II.deviceFamilyIsPentiumMMX(14) The processor family is Pentium MMX™.device
Device Group 297deviceFamilyIsPowerPC603(34) The processor family is Power PC 603.deviceFamilyIsPowerPC603Plus(35)The processor family is Power PC 603
298 Device GroupdeviceFamilyIsmicroSPARCIIep(83)The processor family is microSPARC IIep.deviceFamilyIsUltraSPARC(84) The processor family is UltraSPAR
Device Group 299deviceFamilyIsDualCoreAMDOpteron(135)The processor family is Dual-Core AMD Opteron.deviceFamilyIsAMDAthlon64X2DualCore(136)The process
Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 15Audience . . . . . . . . . . . . . . . . . . . . . . 15What’s New
30 IntroductionThis type of table is used throughout the reference guide to list and define variable values. Tables that explain Server Administrator-
300 Device GroupdeviceFamilyIsIntelPentiumM(185)The processor family is Intel Pentium M.deviceFamilyIsIntelCeleronD(186)The processor family is Intel
Device Group 301Table 13-8. Cache Device LevelVariable Name: DellCacheDeviceLevelData Type: IntegerPossible Data Values Meaning of Data ValuedeviceLev
302 Device GroupTable 13-10. Cache Device Status StateVariable Name: DellCacheDeviceStatusStateData Type: IntegerPossible Data Values Meaning of Data
Device Group 303Table 13-12. Cache Device AssociativityVariable Name: DellCacheDeviceAssociativityData Type: IntegerPossible Data Values Meaning of Da
304 Device GroupTable 13-14. Cache Device Static Random-Access Memory (SRAM) TypeVariable Name: DellCacheDeviceSRAMTypeData Type: IntegerPossible Data
Device Group 305deviceFormFactorIsARowOfChips(11) Device form factor is a row of chips.deviceFormFactorIsRIMM(12) Device form factor is RIMM.deviceFor
306 Device GroupdeviceTypeIsSDRAM(15) Device type is SDRAM.deviceTypeIsSGRAM(16) Device type is SGRAM.deviceTypeIsRDRAM(17) Device type is RDRAM.devic
Device Group 307deviceTypeDetailIsEDO(9) The detailed device type is EDO.deviceTypeDetailIsWindowDRAM(10) The detailed device type is "Window&quo
308 Device GroupTable 13-19. Memory Device Failure ModesVariable Name: DellMemoryDeviceFailureModesData Type: IntegerNOTE: These values are bit masks,
Device Group 309Table 13-20. Network Device Connection StatusVariable Name: DellNetworkDeviceConnectionStatusData Type: IntegerPossible Data Values Me
Introduction 31• BIOS Setup Control Table• SCSI Control Table• Parallel Port Control Table• Serial Port Control Table• USB Control Table• IDE Control
310 Device GroupTable 13-22. Network Device TOE Capability FlagsVariable Name: DellNetworkDeviceTOECapabilityFlagsData Type: IntegerNOTE: These values
Device Group 311Table 13-24. Network Device iSCSI Capability FlagsVariable Name: DellNetworkDeviceiSCSICapabilityFlagsData Type: IntegerNOTE: These va
312 Device Group
Slot Group 313Slot GroupThe Slot Group provides information about the types of slots that your system supports. This management information base (MIB)
314 Slot GroupSystem Slot Chassis IndexSystem Slot IndexSystem Slot State Capabilities Unique System Slot State Settings UniqueName systemSlotchassisI
Slot Group 315System Slot StatusSystem Slot Current UsageSystem Slot TypeSystem Slot External Slot NameName systemSlotStatusObject ID 1.3.6.1.4.1.674.
316 Slot GroupSystem Slot LengthSystem Slot Slot IDSystem Slot CategorySystem Slot Hot-Plug Bus WidthName systemSlotLengthObject ID 1.3.6.1.4.1.674.10
Slot Group 317System Slot Hot-Plug Slot SpeedSystem Slot Hot-Plug Adapter SpeedSystem Slot Variable ValuesThis section includes definitions for server
318 Slot GroupsystemSlotHotPlugCanSignalAttention(8)The system slot attention state (and corresponding LED) can be set.systemSlotHotPlugCanSignalPower
Slot Group 319Table 14-2. System Slot State SettingsVariable Name: DellSystemSlotStateSettingsData Type: IntegerPossible Data Values Meaning of Data V
32 IntroductionIntroduction to the Server Administrator SNMP SubagentThis guide provides formatted information drawn primarily from the MIB files writ
320 Slot GroupsystemSlotSupportsCard16(1024) The system slot supports PC Card-16.systemSlotSupportsCardBus(2048) The system slot supports CardBus.syst
Slot Group 321Table 14-3. System Slot TypeVariable Name: DellSystemSlotTypeData Type: IntegerPossible Data Values Meaning of Data ValuesystemSlotIsOth
322 Slot GroupsystemSlotIsPC98C20(18) The system slot is a PC-98/C20.systemSlotIsPC98C24(19) The system slot is a PC-98/C24.systemSlotIsPC98E(20) The
Slot Group 323Table 14-5. System Slot LengthVariable Name: DellSystemSlotLengthData Type: IntegerPossible Data Values Meaning of Data ValuesystemSlotL
324 Slot Group NOTE: System slot bus width of type "n bits" are for parallel buses such as PCI. NOTE: System slot bus width of type "n
Memory Group 325Memory GroupThe Memory Group provides information about the physical memory in your system. Variables in this group include error corr
326 Memory GroupThe following object sets up the Physical Memory Array Table:Physical Memory Array Table EntryPhysical Memory Array Chassis IndexPhysi
Memory Group 327Physical Memory Array State CapabilitiesPhysical Memory Array State SettingsPhysical Memory Array StatusPhysical Memory Array UseName
328 Memory GroupPhysical Memory Array Error Checking and Correcting (ECC) TypePhysical Memory Array LocationPhysical Memory Array Maximum SizePhysical
Memory Group 329Physical Memory Array In Use Number Sockets Physical Memory Array ECC Error Nonrecoverable ThresholdPhysical Memory Array ECC Error Cr
Introduction 33The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and
330 Memory GroupPhysical Memory Array Redundant Memory Unit Index ReferencePhysical Memory Array Mapped TableThe physical memory array is divided into
Memory Group 331Physical Memory Array Mapped Chassis IndexPhysical Memory Array Mapped IndexPhysical Memory Array Mapped State CapabilitiesPhysical Me
332 Memory GroupPhysical Memory Array Mapped StatusPhysical Memory Array Index ReferencePhysical Memory Array Mapped Starting AddressPhysical Memory A
Memory Group 333Physical Memory Array Mapped Partition WidthPhysical Memory Configuration TableThis table defines how the physical memory of a system
334 Memory GroupPhysical Memory Configuration Chassis IndexPhysical Memory Configuration IndexPhysical Memory Configuration State CapabilitiesPhysical
Memory Group 335Physical Memory Configuration StatusPhysical Memory Configuration Redundant CapabilitiesPhysical Memory Configuration Redundant Settin
336 Memory GroupPhysical Memory Logging Table EntryPhysical Memory Logging Chassis IndexPhysical Memory Logging IndexPhysical Memory Logging Capabilit
Memory Group 337Physical Memory Logging SettingsPhysical Memory Logging StatusRedundant Memory Unit TableThis table reports the status of redundant me
338 Memory GroupRedundant Memory Unit Table EntryRedundant Memory Unit Chassis IndexRedundant Memory Unit IndexRedundant Memory Unit State Capabilitie
Memory Group 339Redundant Memory Unit State SettingsRedundant Memory Unit Redundancy StatusRedundant Memory Unit NameRedundant Memory Unit StatusName
34 IntroductionThe assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an
340 Memory GroupPhysical Memory Card TableThis table defines the name of the memory card, the total number of device slots present on the memory card,
Memory Group 341Physical Memory Card IndexPhysical Memory Card State CapabilitiesPhysical Memory Card State SettingsPhysical Memory Card StatusName ph
342 Memory GroupPhysical Memory Card NamePhysical Memory Card Total Number SocketsPhysical Memory Card In Use Number SocketsName physicalMemoryCardNam
Memory Group 343Physical Memory Card Physical Memory Array Index ReferenceMemory Group Variable ValuesThis section includes definitions for server adm
344 Memory GroupmemoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option
Memory Group 345Table 15-2. Physical Memory Array ECC Type DefinitionsVariable Name: DellPhysicalMemoryArrayECCTypeData Type: IntegerPossible Data Val
346 Memory GroupTable 15-4. Physical Memory Configuration State SettingsVariable Name: DellPhysicalMemoryConfigStateSettings Data Type: IntegerPossibl
Memory Group 347Table 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettingsData Type: Intege
348 Memory GroupTable 15-8. Physical Memory Logging SettingsVariable Name: DellPhysicalMemoryLoggingSettingsData Type: IntegerPossible Data Values Mea
BIOS Setup Control Group 349BIOS Setup Control GroupBasic Input/Output System (BIOS) Setup Control Group variables provide information about the funct
Introduction 35SNMP SecuritySNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configur
350 BIOS Setup Control GroupBIOS Setup Control Table EntryBIOS Setup Control Chassis IndexBIOS Setup Control (BSUC) Pointing Device Control Capabiliti
BIOS Setup Control Group 351BIOS Setup Control Pointing Device Control Status BIOS Setup Control Pointing Device Control NameBIOS Setup Control Numeri
352 BIOS Setup Control GroupBIOS Setup Control Numeric Lock Control StatusBIOS Setup Control Numeric Lock Control NameBIOS Setup Control Processor Ser
BIOS Setup Control Group 353BIOS Setup Control Processor Serial Number Control StatusBIOS Setup Control Processor Serial Number Control NameBIOS Setup
354 BIOS Setup Control GroupBIOS Setup Control Speaker Control StatusBIOS Setup Control Speaker Control NameBIOS Setup Control NIF Wakeup on LAN Contr
BIOS Setup Control Group 355BIOS Setup Control NIF Wakeup on LAN Control StatusBIOS Setup Control NIF Wakeup on LAN Control NameBIOS Setup Control Boo
356 BIOS Setup Control GroupBIOS Setup Control Boot Sequence Control StatusBIOS Setup Control Boot Sequence Control NameBIOS Setup Control Administrat
BIOS Setup Control Group 357BIOS Setup Control Administrator Password Control StatusBIOS Setup Control Administrator Password Verify NameBIOS Setup Co
358 BIOS Setup Control GroupBIOS Setup Control User Password Control Settings UniqueBIOS Setup Control User Password Control StatusBIOS Setup Control
BIOS Setup Control Group 359BIOS Setup Control TPM Security Control CapabilitiesBIOS Setup Control TPM Security Control SettingBIOS Setup Control TPM
36 IntroductionSNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so
360 BIOS Setup Control GroupSCSI Control TableSCSI Control Table EntrySCSI Control Chassis IndexSCSI Control IndexName sCSIControlTableObject ID 1.3.6
BIOS Setup Control Group 361SCSI Control CapabilitiesSCSI Control SettingsSCSI Control StatusSCSI Control NameName sCSIControlCapabilitiesObject ID 1.
362 BIOS Setup Control GroupParallel Port Control TableParallel Port Control Table EntryParallel Port Control Chassis Index Parallel Port Control Inde
BIOS Setup Control Group 363Parallel Port Control Capabilities UniqueParallel Port Control Settings UniqueParallel Port Control StatusParallel Port Co
364 BIOS Setup Control GroupParallel Port Control Mode Capabilities UniqueParallel Port Control Mode Settings UniqueSerial Port Control TableSerial Po
BIOS Setup Control Group 365Serial Port Control Chassis IndexSerial Port Control IndexSerial Port Control Capabilities UniqueSerial Port Control Setti
366 BIOS Setup Control GroupSerial Port Control StatusSerial Port Control NameUSB Control TableThese objects enable you to track the attributes of you
BIOS Setup Control Group 367USB Control Chassis IndexUSB Control IndexUSB Control CapabilitiesUSB Control SettingsName usbControlchassisIndexObject ID
368 BIOS Setup Control GroupUSB Control StatusUSB Control NameIDE Control TableThese objects enable you to track the attributes of Integrated Device E
BIOS Setup Control Group 369IDE Control Chassis IndexIDE Control IndexIDE Control Capabilities UniqueIDE Control Settings UniqueName ideControlchassis
Instrumentation MIB Version Group 37Instrumentation MIB Version GroupThe Instrumentation Management Information Base (MIB) Version Group defines the a
370 BIOS Setup Control GroupIDE Control StatusIDE Control NameDiskette Control TableDiskette Control Table EntryName ideControlStatusObject ID 1.3.6.1
BIOS Setup Control Group 371Diskette Control Chassis IndexDiskette Control IndexDiskette Control Capabilities UniqueDiskette Control Settings UniqueNa
372 BIOS Setup Control GroupDiskette Control StatusDiskette Control NameNetwork Interface Control TableThese MIB objects enable you to track the attri
BIOS Setup Control Group 373Network Interface Control Table EntryNetwork Interface Control Chassis IndexNetwork Interface Control IndexName networkInt
374 BIOS Setup Control GroupNetwork Interface Control Capabilities UniqueNetwork Interface Control Settings UniqueNetwork Interface Control StatusNetw
BIOS Setup Control Group 375BIOS Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this
376 BIOS Setup Control GroupTable 16-3. Network Interface (NIF) Wakeup on LAN Capabilities UniqueVariable Name: DellNIFwakeonLanControlCapabilitiesUni
BIOS Setup Control Group 377Table 16-5. Boot Sequence Control Capabilities UniqueVariable Name: DellBootSequenceControlCapabilitiesUniqueData Type: In
378 BIOS Setup Control GroupTable 16-7. BIOS Password Control CapabilitiesVariable Name: DellBIOSPasswordControlCapabilitiesData Type: IntegerPossible
BIOS Setup Control Group 379Table 16-9. BIOS Password Control SettingsVariable Name: DellBIOSPasswordControlSettingsUnique Data Type: IntegerPossible
38 Instrumentation MIB Version GroupMIB Minor Version NumberMIB Maintenance Version NumberName mIBMinorVersionNumberObject ID 1.3.6.1.4.1.674.10892.1.
380 BIOS Setup Control GroupTable 16-12. Parallel Port Control CapabilitiesVariable Name: DellParallelPortControlCapabilitiesUniqueData Type: IntegerP
BIOS Setup Control Group 381Table 16-14. Parallel Port Control Mode SettingsVariable Name: DellParallelPortControlModeSettingsUniqueData Type: Integer
382 BIOS Setup Control Groupcom1OrCom3CapableAndAutoConfigCapable(86)Setup BIOS has enabled autoconfiguration of COM1 and COM3 serial ports. com2OrCom
BIOS Setup Control Group 383Table 16-17. IDE Control CapabilitiesVariable Name: DellideControlCapabilitiesUniqueData Type: IntegerPossible Data Values
384 BIOS Setup Control GroupTable 16-20. Network Interface Control SettingsVariable Name: DellNetworkInterfaceControlSettingsUniqueData Type: IntegerP
Local Response Agent Group 385Local Response Agent GroupThe Local Response Agent Group provides information about various attributes of your system’s
386 Local Response Agent GroupLRA Global Settings TableLRA Global Settings Table EntryLRA Global Chassis IndexLRA Global StateName lRAGlobalSettingsTa
Local Response Agent Group 387LRA Global Settings Disable Time-out ValueLRA Global Settings Capabilities UniqueLRA Global Thermal Shutdown Capabilitie
388 Local Response Agent GroupLRA Action TableThe DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilitie
Local Response Agent Group 389LRA Action Table Action Number IndexName lRAActionTableActionNumberIndexObject ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2Des
Systems Management Software Group 39Systems Management Software GroupThe Systems Management Software Group allows users to see information about the s
390 Local Response Agent GroupLRA Action Table User Application NameLRA Action Table Settings UniqueLocal Response Agent Variable ValuesThis section i
Local Response Agent Group 391rebootCapable(16) The LRA can reboot the system.powerCycleCapable(32) The LRA is capable of a system power cycle.powerOF
392 Local Response Agent GroupenableOnFailureCapable(10) The LRA enables activation of chassis-determined action(s) when a failure condition is detect
Cost of Ownership Group 393Cost of Ownership GroupThe Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for
394 Cost of Ownership GroupCost of Ownership Table EntryCOO Chassis IndexCOO StateCOO Acquisition Purchase CostName cooTableEntryObject ID 1.3.6.1.4.1
Cost of Ownership Group 395COO Acquisition Waybill NumberCOO Acquisition Install Date Name COO Acquisition Purchase Order COO Acquisition Purchase Dat
396 Cost of Ownership GroupCOO Acquisition Signing Authority NameCOO Original Machine Configuration ExpensedCOO Original Machine Configuration Vendor
Cost of Ownership Group 397COO User Information User NameCOO Extended Warranty Start Date NameCOO Extended Warranty End Date NameCOO Extended Warranty
398 Cost of Ownership GroupCOO Extended Warranty Provider NameCOO Ownership CodeCOO Corporate Owner NameCOO Hazardous Waste Code NameName cooExtendedW
Cost of Ownership Group 399COO Deployment Date LengthCOO Deployment Duration TypeCOO Training NameCOO Outsourcing Problem Description NameName cooDepl
4 ContentsSection Organization . . . . . . . . . . . . . . . . 30Other Documents You May Need . . . . . . . . . 31Introduction to the Server Admin
40 Systems Management Software GroupSystems Management SoftwareThe following objects describe the fields for server administrator systems management i
400 Cost of Ownership GroupCOO Outsourcing Service Fee NameCOO Outsourcing Signing Authority NameCOO Outsourcing Provider Fee NameCOO Outsourcing Prov
Cost of Ownership Group 401COO Insurance Company NameCOO Box Asset Tag NameCOO Box System NameCOO Box Central Processing Unit (CPU) Serial Number Name
402 Cost of Ownership GroupCOO Operating System Upgrade Type NameCOO Operating System Upgrade Patch Level NameCOO Operating System Upgrade Date COO De
Cost of Ownership Group 403COO Depreciation Duration TypeCOO Depreciation PercentageCOO Depreciation Method NameCOO Registration Is RegisteredName coo
404 Cost of Ownership GroupCOO Service Contract TableThe service contract table provides MIB objects that help you track the name, vendor, and type of
Cost of Ownership Group 405COO Service Contract StateCOO Service Contract Was RenewedCOO Service Contract Type NameCOO Service Contract Vendor NameNam
406 Cost of Ownership GroupCOO Cost Event Log TableThe COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of
Cost of Ownership Group 407COO Cost Event Log StateCOO Cost Event Log DurationCOO Cost Event Log Duration TypeCOO Cost Event Log Description NameName
408 Cost of Ownership GroupCOO Warranty TableThe COO Warranty Table objects enable you to track facts about the type and duration of the warranty for
Cost of Ownership Group 409COO Warranty StateCOO Warranty DurationCOO Warranty Duration TypeCOO Warranty End Date NameName cooWarrantyStateObject ID 1
Systems Management Software Group 41Systems Management Software Description NameSystems Management Software Supported Protocol Systems Management Soft
410 Cost of Ownership GroupCOO Warranty CostCOO Lease Information TableThe COO lease information MIB objects enable you to track information about you
Cost of Ownership Group 411COO Lease Information IndexCOO Lease Information StateCOO Lease Information Multiple SchedulesCOO Lease Information Buyout
412 Cost of Ownership GroupCOO Lease Information Lease Rate FactorCOO Lease Information End Date NameCOO Lease Information Fair Market ValueCOO Lease
Cost of Ownership Group 413COO Schedule Number TableCOO Schedule Number Table EntryCOO Schedule Number Chassis IndexCOO Schedule Number IndexName cooS
414 Cost of Ownership GroupCOO Schedule Number StateCOO Schedule Number Lease Information Index ReferenceCOO Schedule Number Description NameCOO Optio
Cost of Ownership Group 415COO Options Table EntryCOO Options Chassis IndexCOO Options IndexCOO Options StateName cooOptionsTableEntryObject ID 1.3.6.
416 Cost of Ownership GroupCOO Options Lease Information Index ReferenceCOO Options Description NameCOO Maintenance TableCOO Maintenance Table EntryNa
Cost of Ownership Group 417COO Maintenance Chassis Index COO Maintenance IndexCOO Maintenance StateCOO Maintenance Start Date NameName cooMaintenancec
418 Cost of Ownership GroupCOO Maintenance End Date NameCOO Maintenance Provider NameCOO Maintenance Restrictions NameCOO Repair TableName cooMaintena
Cost of Ownership Group 419COO Repair Table EntryCOO Repair Chassis IndexCOO Repair IndexCOO Repair StateName cooRepairTableEntryObject ID 1.3.6.1.4.1
42 Systems Management Software GroupSystems Management Software URL NameSystems Management Software Language NameSystems Management Software Global Ve
420 Cost of Ownership GroupCOO Repair CounterCOO Repair Vendor NameCOO Support Information TableCOO Support Information Table EntryName cooRepairCount
Cost of Ownership Group 421COO Support Information Chassis IndexCOO Support Information IndexCOO Support Information StateCOO Support Information Is O
422 Cost of Ownership GroupCOO Support Information TypeCOO Support Information Help Desk NameCOO Support Information Fix Type NameCOO Trouble Ticket T
Cost of Ownership Group 423COO Trouble Ticket Table EntryCOO Trouble Ticket Chassis IndexCOO Trouble Ticket IndexCOO Trouble Ticket StateName cooTroub
424 Cost of Ownership GroupCOO Trouble Ticket Support Information Index ReferenceCOO Trouble Ticket Number NameCost of Ownership Variable ValuesThis s
Cost of Ownership Group 425Table 18-2. COO Hour Day Duration TypeVariable Name: DellCooHourDayDurationTypeData Type: IntegerPossible Data Values Meani
426 Cost of Ownership Group
Remote Access Group 427Remote Access GroupThe Remote Access Group provides information about the remote access hardware that may be present in your sy
428 Remote Access GroupRemote Access Chassis IndexRemote Access Adapter IndexRemote Access TypeRemote Access State CapabilitiesName remoteAccessChassi
Remote Access Group 429Remote Access State SettingsRemote Access StatusRemote Access Product Info NameRemote Access Description Info NameName remoteAc
Systems Management Software Group 43Systems Management Software SNMP Agent Feature FlagsSystems Management Software Manufacturer NameSystems Managemen
430 Remote Access GroupRemote Access Version Info NameRemote Access Local Area Network (LAN) CapabilitiesRemote Access LAN SettingsRemote Access Netwo
Remote Access Group 431Remote Access NIC Static Netmask AddressRemote Access NIC Static Gateway AddressRemote Access Personal Computer Memory Card Int
432 Remote Access GroupRemote Access Miscellaneous Information NameRemote Access NIC Current IP AddressRemote Access NIC Current Netmask AddressRemote
Remote Access Group 433Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)Remote Access Remote Connect URLDRAC IIIOn
434 Remote Access GroupRemote Access TableThe following MIB object sets up the Remote Access Table.Remote Access Table EntryRemote Access Chassis Inde
Remote Access Group 435Remote Access TypeRemote Access State CapabilitiesRemote Access State SettingsRemote Access StatusName remoteAccessTypeObject I
436 Remote Access GroupRemote Access Product Info NameRemote Access Description Info NameRemote Access Version Info NameRemote Access Control Capabili
Remote Access Group 437Remote Access Control SettingsRemote Access Monitor CapabilitiesRemote Access Monitor SettingsRemote Access Local Area Network
438 Remote Access GroupRemote Access LAN SettingsRemote Access Host CapabilitiesRemote Access Host SettingsRemote Access Out-of-Band Simple Network Ma
Remote Access Group 439Remote Access Out-of-Band SNMP SettingsRemote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address
44 Systems Management Software GroupTable 3-2. Systems Management Software Feature FlagsVariable Name: SMSFeatureFlagsData Type: IntegerPossible Data
440 Remote Access GroupRemote Access Firmware Update IP AddressRemote Access Firmware Update Path NameRemote Access Network Interface Controller (NIC)
Remote Access Group 441Remote Access NIC Static Gateway AddressRemote Access Personal Computer Memory Card International Association (PCMCIA) Info Nam
442 Remote Access GroupRemote Access NIC Current IP AddressRemote Access NIC Current Netmask AddressRemote Access NIC Current Gateway AddressName remo
Remote Access Group 443Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)Remote User Administration TableRemote Use
444 Remote Access GroupRemote User Admin Chassis IndexRemote User Admin Adapter IndexRemote User Admin User IndexRemote User Admin State CapabilitiesN
Remote Access Group 445Remote User Admin State SettingsRemote User Admin StatusRemote User Admin User NameRemote User Admin User Password NameName rem
446 Remote Access GroupRemote User Admin User PrivilegeRemote User Admin User Privilege CapabilitiesRemote User Admin Alert Filter DRS Events MaskRemo
Remote Access Group 447Remote User Admin Alert Filter DRS CapabilitiesRemote User Admin Alert Filter System CapabilitiesRemote User Admin Pager Numeri
448 Remote Access GroupRemote User Admin Pager Numeric Hang-up DelayRemote User Admin Pager Alpha Phone Number NameRemote User Admin Pager Alpha Proto
Remote Access Group 449Remote User Admin Pager Alpha Custom Message NameRemote User Admin Pager Alpha Modem Connect Time-outRemote User Admin Pager Al
System State Group 45System State GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attribute
450 Remote Access GroupRemote User Admin Pager Modem Init String NameRemote User Admin Pager Modem PortRemote User Admin E-Mail Address NameRemote Use
Remote Access Group 451Remote User Admin Control CapabilitiesRemote User Admin Control SettingsRemote User Admin User TypeRemote SNMP Trap TableName r
452 Remote Access GroupRemote SNMP Trap Table EntryRemote SNMP Trap Chassis IndexRemote SNMP Trap Adapter IndexName remoteSNMPTrapTableEntryObject ID
Remote Access Group 453Remote SNMP Trap IndexRemote SNMP Trap State CapabilitiesRemote SNMP Trap State SettingsRemote SNMP Trap StatusName remoteSNMPT
454 Remote Access GroupRemote SNMP Trap Destination IP AddressRemote SNMP Trap SNMP Community NameRemote SNMP Trap Filter DRS Events MaskRemote SNMP T
Remote Access Group 455Remote SNMP Trap Filter DRS CapabilitiesRemote SNMP Trap Filter System CapabilitiesRemote SNMP Trap Control CapabilitiesRemote
456 Remote Access GroupRemote Dial-Up TableRemote Dial-Up Table EntryRemote Dial-Up Chassis IndexName remoteDialUpTableObject ID 1.3.6.1.4.1.674.10892
Remote Access Group 457Remote Dial-Up Adapter IndexRemote Dial-Up IndexRemote Dial-Up State CapabilitiesRemote Dial-Up State SettingsName remoteDialUp
458 Remote Access GroupRemote Dial-Up StatusRemote Dial-Up PPP Dial-In Base IP AddressRemote Dial-Up PPP Dial-In Idle Time-outRemote Dial-Up PPP Dial-
Remote Access Group 459Remote Dial-Up Dial-Out Modem Connect Time-outRemote Dial-Up Modem Dial TypeRemote Dial-Up Modem Init String NameRemote Dial-Up
46 System State GroupSystem State Chassis IndexSystem State Global System StatusSystem State Chassis StateSystem State Chassis StatusName systemStatec
460 Remote Access GroupRemote Dial-Up Modem PortRemote User Dial-In Configuration TableRemote User Dial-In Configuration Table EntryName remoteDialUpM
Remote Access Group 461Remote User Dial-In Configuration Chassis IndexRemote User Dial-In Configuration Adapter IndexRemote User Dial-In Configuration
462 Remote Access GroupRemote User Dial-In Configuration State SettingsRemote User Dial-In Configuration StatusRemote User Dial-In Configuration PPP U
Remote Access Group 463Remote User Dial-In Configuration Callback Phone Number NameRemote Dial-Out TableRemote Dial-Out Table EntryRemote Dial-Out Cha
464 Remote Access GroupRemote Dial-Out Adapter IndexRemote Dial-Out Dial-Out IndexRemote Dial-Out State CapabilitiesRemote Dial-Out State SettingsName
Remote Access Group 465Remote Dial-Out StatusRemote Dial-Out IP AddressRemote Dial-Out Phone Number NameRemote Dial-Out PPP UsernameName remoteDialOut
466 Remote Access GroupRemote Dial-Out PPP Password NameRemote Access Variable ValuesThis section includes definitions for server administrator-specif
Remote Access Group 467logResetCapable(2) The remote access hardware can reset its integrated logs.hardResetCapable(4) The remote access hardware can
468 Remote Access GroupgracefulReset(16) The remote access hardware will gracefully shut down and perform a soft reset.defaultConfigReset(32) The remo
Remote Access Group 469Table 19-5. Remote Access Monitor SettingsVariable Name: DellRemoteAccessMonitorSettingsData Type: IntegerPossible Data Values
System State Group 47System State Power Unit State DetailsSystem State Power Unit Status RedundancySystem State Power Unit Status DetailsName systemSt
470 Remote Access GroupTable 19-7. Remote Access LAN SettingsVariable Name: DellRemoteAccessLANSettingsData Type: IntegerPossible Data Values Meaning
Remote Access Group 471Table 19-9. Remote Access Host SettingsVariable Name: DellRemoteAccessHostSettingsData Type: IntegerPossible Data Values Meanin
472 Remote Access GroupTable 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) SettingsVariable Name: DellRemoteAccessOutOfBa
Remote Access Group 473Table 19-13. Remote User Admin State SettingsVariable Name: DellRemoteUserAdminStateSettingsData Type: IntegerPossible Data Val
474 Remote Access GroupTable 19-15. Remote User Admin Control SettingsVariable Name: DellRemoteUserAdminControlSettingsData Type: IntegerPossible Data
Remote Access Group 475Table 19-17. Remote User Admin Alpha Baud TypeVariable Name: DellRemoteUserAdminAlphaBaudTypeData Type: IntegerPossible Data Va
476 Remote Access GroupTable 19-20. Remote SNMP Trap Control CapabilitiesVariable Name: DellRemoteSNMPTrapControlCapabilitiesData Type: IntegerPossibl
Remote Access Group 477notReadyCapable(4) The dial-up functionality can be in the "not ready" state.dialInCapable(8) The dial-up functionali
478 Remote Access GroupdialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature.dialInAuthAnyEnabled(
Remote Access Group 479Table 19-25. Remote User Dial-In State CapabilitiesVariable Name: DellRemoteUserDialInStateCapabilitiesData Type: IntegerPossib
48 System State GroupSystem State Power Supply State DetailsSystem State Power Supply Status CombinedSystem State Power Supply Status DetailsName syst
480 Remote Access GroupTable 19-27. Remote Dial-Out State CapabilitiesVariable Name: DellRemoteDialOutStateCapabilitiesData Type: IntegerPossible Data
Remote Access Group 481Table 19-28. Remote Dial-Out State SettingsVariable Name: DellRemoteDialOutStateSettingsData Type: IntegerPossible Data Values
482 Remote Access Group
Cluster Group 483Cluster GroupClustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhance
484 Cluster GroupCluster Chassis IndexCluster IndexCluster State CapabilitiesCluster State SettingsName clusterChassisIndexObject ID 1.3.6.1.4.1.674.1
Cluster Group 485Cluster StatusCluster TypeCluster Type Description NameCluster NameName clusterStatusObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5Des
486 Cluster GroupCluster Group Variable ValuesThis section includes definitions for Server Administrator-specific variable values used in this section
Baseboard Management Controller Group 487Baseboard Management Controller GroupThe Baseboard Management Controller (BMC) monitors the system for critic
488 Baseboard Management Controller GroupBMC Table EntryBMC Chassis IndexBMC IndexBMC State CapabilitiesName bmcTableEntryObject ID 1.3.6.1.4.1.674.10
Baseboard Management Controller Group 489BMC State SettingsBMC StatusBMC Display NameBMC Description NameName bmcStateSettingsObject ID 1.3.6.1.4.1.67
System State Group 49System State Voltage State DetailsSystem State Voltage Status CombinedSystem State Voltage Status DetailsName systemStateVoltageS
490 Baseboard Management Controller GroupBMC IPMI Version NameBMC GUIDBMC TypeBMC Module NameName bmcIPMIVersionNameObject ID 1.3.6.1.4.1.674.10892.1.
Baseboard Management Controller Group 491Baseboard Management Controller Serial Interface TableBMC Serial Interface Table EntryBMC Serial Interface Ch
492 Baseboard Management Controller GroupBMC Serial Interface IndexBMC Serial Interface State CapabilitiesBMC Serial Interface State SettingsBMC Seria
Baseboard Management Controller Group 493BMC Serial Interface Channel NumberBMC Serial Interface Connection Mode CapabilitiesBMC Serial Interface Conn
494 Baseboard Management Controller GroupBMC Serial Interface Bit RateBaseboard Management Controller LAN Interface TableBMC LAN Interface Table Entry
Baseboard Management Controller Group 495BMC LAN Interface Chassis IndexBMC LAN Interface BMC IndexBMC LAN Interface IndexBMC LAN Interface State Capa
496 Baseboard Management Controller GroupBMC LAN Interface State SettingsBMC LAN Interface StatusBMC LAN Interface Channel NumberBMC LAN Interface IP
Baseboard Management Controller Group 497BMC LAN Interface IP AddressBMC LAN Interface Subnet Mask AddressBMC LAN Interface Default Gateway AddressBMC
498 Baseboard Management Controller GroupBMC LAN Interface Alert Community NameBaseboard Management Controller Group Variable ValuesThis section inclu
Baseboard Management Controller Group 499Table 21-2. BMC Serial Connection Mode SettingsVariable Name: DellBMCSerialConnectionModeSettingsData Type: I
Contents 5Systems Management Software Language Name . . . . . . . . . . . . . . . . . . 42Systems Management Software Global Version Name. . . . . .
50 System State GroupSystem State Amperage State DetailsSystem State Amperage Status CombinedSystem State Amperage Status DetailsName systemStateAmper
500 Baseboard Management Controller GroupTable 21-4. BMC Serial Bit Rate TypeVariable Name: DellBMCSerialBitRateTypeData Type: IntegerPossible Data Va
Field Replaceable Unit Group 501Field Replaceable Unit GroupA field replaceable unit (FRU) is a part that can be removed and replaced without having t
502 Field Replaceable Unit GroupFRU Chassis IndexFRU IndexFRU Information StatusFRU Information State Name fruChassisIndexObject ID 1.3.6.1.4.1.674.10
Field Replaceable Unit Group 503FRU Device Name FRU Manufacturer Name FRU Serial Number NameFRU Part Number NameName fruDeviceNameObject ID 1.3.6.1.4.
504 Field Replaceable Unit GroupFRU Revision NameFRU Manufacturing Date NameFRU Asset Tag NameName fruRevisionNameObject ID 1.3.6.1.4.1.674.10892.1.20
Field Replaceable Unit Group 505FRU Group Variable ValuesThis section includes definitions for server administrator-specific variable values.Table 22-
506 Field Replaceable Unit Group
Storage Management Group 507Storage Management GroupThe Storage Management Group is composed of the following:• Storage Management Group—information a
508 Storage Management GroupGlobal StatusSoftware ManufacturerSoftware ProductName globalStatusObject ID 1.3.6.1.4.1.674.10893.1.20.2Description Ident
Storage Management Group 509Software DescriptionStorage Management Information GroupThe Storage Management Information MIB Group defines the propertie
System State Group 51System State Cooling Unit State DetailsSystem State Cooling Unit Status RedundancySystem State Cooling Unit State DetailsName sta
510 Storage Management GroupAgent VendorAgent VersionGlobal Data GroupThe Global Data Management Information Base (MIB) Group defines the properties t
Storage Management Group 511Agent Last Global StatusAgent Time StampAgent Get TimeoutName agentLastGlobalStatusObject ID 1.3.6.1.4.1.674.10893.1.20.11
512 Storage Management GroupAgent ModifiersAgent Refresh RateAgent HostnameName agentModifiersObject ID 1.3.6.1.4.1.674.10893.1.20.110.5Description Id
Storage Management Group 513Agent IP AddressAgent Software StatusAgent SNMP VersionAgent MIB VersionName agentIPAddressObject ID 1.3.6.1.4.1.674.10893
514 Storage Management GroupAgent Management Software URL NameAgent Global System StatusName agentManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.1
Storage Management Group 515Agent Last Global System StatusAgent Smart Thermal ShutdownName agentLastGlobalSystemStatusObject ID 1.3.6.1.4.1.674.10893
516 Storage Management GroupPhysical Devices GroupThe Physical Devices MIB group provides information about the devices managed by the Storage Managem
Storage Management Group 517•Temperature Probe Table—describes available properties for each temperature probe on the managed system.•Temperature Prob
518 Storage Management GroupController EntryController NumberController NameName controllerEntryObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1Descriptio
Storage Management Group 519Controller VendorController TypeName controllerVendorObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3Description Identifies
52 System State GroupSystem State Cooling Device State DetailsSystem State Cooling Device Status CombinedSystem State Cooling Device Status DetailsNam
520 Storage Management GroupController StateController SeverityController Rebuild Rate in PercentName controllerStateObject ID 1.3.6.1.4.1.674.10893.1
Storage Management Group 521Controller Firmware VersionController Cache Size in MegabytesController Cache Size in BytesController Physical Device Coun
522 Storage Management GroupController Logical Device CountController Partner StatusController Host Port CountController Memory Size in MegabytesName
Storage Management Group 523Controller Memory Size in BytesController Drive Channel CountController Fault TolerantName controllerMemorySizeInBytesObje
524 Storage Management GroupController C0 Port 0 World Wide NameController C0 Port 0 NameController C0 Port 0 IDController C0 TargetName controllerC0P
Storage Management Group 525Controller C0 ChannelController C0 Operating System ControllerController C0 Battery StateController C1 Port 0 World Wide N
526 Storage Management GroupController C1 Port 0 NameController C1 Port 0 IDController C1 TargetController C1 ChannelName controllerC1Port0NameObject
Storage Management Group 527Controller C1 Operating System ControllerController Battery State C1Controller Node World Wide NameController C0 Port 1 Wo
528 Storage Management GroupController C1 Port 1 World Wide NameController Battery Charge CountController Roll-Up StatusName controllerC1Port1WWNObjec
Storage Management Group 529Controller Component StatusController Nexus IDController Alarm StateName controllerComponentStatusObject ID 1.3.6.1.4.1.67
System State Group 53System State Temperature State DetailsSystem State Temperature Status CombinedSystem State Temperature Status DetailsName systemS
530 Storage Management GroupController Driver VersionController PCI SlotController Cluster ModeName controllerDriverVersionObject ID 1.3.6.1.4.1.674.1
Storage Management Group 531Controller Minimum Firmware VersionController Minimum Driver VersionController SCSI Initiator IDController Channel CountNa
532 Storage Management GroupController Reconstruct RateController Patrol Read RateController BGI RateController Check Consistency RateName controllerR
Storage Management Group 533Controller Patrol Read ModeController Patrol Read StateController Patrol Read IterationsName controllerPatrolReadModeObjec
534 Storage Management GroupChannel TableThis table describes available properties for each channel on the managed system.The following object sets up
Storage Management Group 535Channel NameChannel StateChannel SeverityName channelNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2Description Identif
536 Storage Management GroupChannel TerminationChannel SCSI IDName channelTerminationObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5Description Identif
Storage Management Group 537Channel Roll-Up StatusChannel Component StatusName channelRollUpStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7Descri
538 Storage Management GroupChannel Nexus IDChannel Data RateChannel Bus TypeName channelNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9Descript
Storage Management Group 539Enclosure TableThis table describes available properties for each enclosure on the managed system.The following object set
54 System State GroupSystem State Memory Device State DetailsSystem State Memory Device Status CombinedSystem State Memory Device Status DetailsName s
540 Storage Management GroupEnclosure NameEnclosure VendorEnclosure StateName enclosureNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2Description I
Storage Management Group 541Enclosure SeverityEnclosure IDEnclosure Processor VersionEnclosure Service TagName enclosureSeverityObject ID 1.3.6.1.4.1.
542 Storage Management GroupEnclosure Asset TagEnclosure Asset NameEnclosure Split Bus Part NumberEnclosure Product IDName enclosureAssetTagObject ID
Storage Management Group 543Enclosure Kernel VersionEnclosure ESM1 Part NumberEnclosure ESM2 Part NumberName enclosureKernelVersionObject ID 1.3.6.1.4
544 Storage Management GroupEnclosure TypeEnclosure Processor2 VersionName enclosureTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16Description Ind
Storage Management Group 545Enclosure ConfigurationEnclosure Channel NumberEnclosure AlarmName enclosureConfigObject ID 1.3.6.1.4.1.674.10893.1.20.130
546 Storage Management GroupEnclosure Backplane Part NumberEnclosure SCSI IDEnclosure Roll-Up StatusName enclosureBackplanePartNumberObject ID 1.3.6.1
Storage Management Group 547Enclosure Component StatusEnclosure Nexus IDEnclosure FirmWare VersionName enclosureComponentStatusObject ID 1.3.6.1.4.1.6
548 Storage Management GroupEnclosure SCSI RateEnclosure Part NumberEnclosure Serial NumberEnclosure SAS AddressName enclosureSCSIRateObject ID 1.3.6.
Storage Management Group 549Array Disk TableThis table describes available properties for each physical array disk on the managed system.The following
System State Group 55System State Chassis Intrusion State DetailsSystem State Chassis Intrusion Status CombinedSystem State Chassis Intrusion Status D
550 Storage Management GroupArray Disk NameArray Disk VendorName arrayDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2Description Identifies the
Storage Management Group 551Array Disk StateName arrayDiskStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4Description Identifies the current state
552 Storage Management GroupArray Disk SeverityArray Disk Product IDArray Disk Serial NumberArray Disk RevisionName arrayDiskSeverityObject ID 1.3.6.1
Storage Management Group 553Array Disk Enclosure IDArray Disk ChannelArray Disk Length in MegabytesArray Disk Length in BytesName arrayDiskEnclosureID
554 Storage Management GroupArray Disk Largest Contiguous Free Space in MegabytesArray Disk Largest Contiguous Free Space in BytesArray Disk Target ID
Storage Management Group 555Array Disk Used Space in MegabytesArray Disk Used Space in BytesArray Disk Free Space in MegabytesName arrayDiskUsedSpaceI
556 Storage Management GroupArray Disk Free Space in BytesArray Disk Bus TypeName arrayDiskFreeSpaceInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.
Storage Management Group 557Array Disk Spare StateArray Disk Roll-Up StatusName arrayDiskSpareStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22Desc
558 Storage Management GroupArray Disk Component StatusArray Disk Device NameArray Disk Nexus IDName arrayDiskComponentStatusObject ID 1.3.6.1.4.1.674
Storage Management Group 559Array Disk Part NumberArray Disk SAS AddressArray Disk Negotiated SpeedArray Disk Capable SpeedName arrayDiskPartNumberObj
56 System State GroupSystem State AC Power Switch State DetailsSystem State AC Power Switch Status RedundancySystem State AC Power Switch Status Detai
560 Storage Management GroupArray Disk Smart Alert IndicationArray Disk Manufacture DayArray Disk Manufacture WeekName arrayDiskSmartAlertIndicationOb
Storage Management Group 561Array Disk Manufacture YearArray Disk Enclosure Connection TableThis table describes the connections among array disks, th
562 Storage Management GroupArray Disk Enclosure Connection NumberArray Disk Enclosure Connection Array Disk NameArray Disk Enclosure Connection Array
Storage Management Group 563Array Disk Enclosure Connection Enclosure NumberArray Disk Enclosure Connection Controller NameArray Disk Enclosure Connec
564 Storage Management GroupThe following object sets up the Array Disk Channel Connection Table.Array Disk Channel Connection EntryArray Disk Channel
Storage Management Group 565Array Disk Channel Connection Array Disk NumberArray Disk Channel Connection Channel NameArray Disk Channel Connection Cha
566 Storage Management GroupArray Disk Channel Connection Controller NumberFan TableThis table describes available properties for each fan on the mana
Storage Management Group 567Fan NumberFan NameFan VendorName fanNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1Description Identifies the instanc
568 Storage Management GroupFan StateFan SeverityFan Probe UnitName fanStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4Description Identifies the c
Storage Management Group 569Fan Probe Minimum WarningFan Probe Minimum CriticalFan Probe Maximum WarningFan Probe Maximum CriticalName fanProbeMinimum
System State Group 57System State AC Power Cord State DetailsSystem State AC Power Cord Status CombinedSystem State AC Power Cord Status DetailsName s
570 Storage Management GroupFan Probe Current ValueFan1 Part NumberFan 2 Part NumberName fanProbeCurrValueObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1
Storage Management Group 571Fan Roll-Up StatusFan Component StatusName fanRollUpStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14Description Sever
572 Storage Management GroupFan Nexus IDFan RevisionFan Connection TableThis table describes the connection between each fan on the managed system and
Storage Management Group 573Fan Connection EntryFan Connection NumberFan Connection Fan NameFan Connection Fan NumberName fanConnectionEntryObject ID
574 Storage Management GroupFan Connection Enclosure NameFan Connection Enclosure NumberPower Supply TableThis table describes available properties fo
Storage Management Group 575Power Supply EntryPower Supply NumberPower Supply NamePower Supply VendorName powerSupplyEntryObject ID 1.3.6.1.4.1.674.10
576 Storage Management GroupPower Supply StatePower Supply SeverityPower Supply 1 Part NumberName powerSupplyStateObject ID 1.3.6.1.4.1.674.10893.1.20
Storage Management Group 577Power Supply 2 Part NumberPower Supply Roll-Up StatusName powerSupply2PartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.9
578 Storage Management GroupPower Supply Component StatusPower Supply NexusIDPower Supply RevisionName powerSupplyComponentStatusObject ID 1.3.6.1.4.1
Storage Management Group 579Power Supply Connection TableThis table describes the connection between each power supply on the managed system and its e
58 System State GroupSystem State Redundant Memory Unit State DetailsSystem State Redundant Memory Unit Status RedundancySystem State Redundant Memory
580 Storage Management GroupPower Supply Connection Power Supply NamePower Supply Connection Power Supply NumberPower Supply Connection Enclosure Name
Storage Management Group 581Temperature Probe Table This table describes available properties for each temperature probe on the managed system.The fol
582 Storage Management GroupTemperature Probe NameTemperature Probe VendorTemperature Probe StateName temperatureProbeNameObject ID 1.3.6.1.4.1.674.10
Storage Management Group 583Temperature Probe SeverityTemperature Probe UnitTemperature Probe Minimum WarningTemperature Probe Minimum CriticalName te
584 Storage Management GroupTemperature Probe Maximum WarningTemperature Probe Maximum CriticalTemperature Probe Current ValueName temperatureProbeMax
Storage Management Group 585Temperature Probe Roll-Up StatusTemperature Probe Component StatusName temperatureProbeRollUpStatusObject ID 1.3.6.1.4.1.6
586 Storage Management GroupTemperature Probe Nexus IDTemperature Probe Connection TableThis table describes the connection between each temperature p
Storage Management Group 587Temperature Probe Connection NumberTemperature Probe Connection Temperature Probe NameTemperature Probe Connection Tempera
588 Storage Management GroupTemperature Probe Connection Enclosure NumberEnclosure Management Module TableThis table describes available properties fo
Storage Management Group 589Enclosure Management Module NumberEnclosure Management Module NameEnclosure Management Module VendorName enclosureManageme
System State Group 59System State Event Log StatusSystem State Power Unit Status CombinedSystem State Power Unit Status ListName systemStateEventLogSt
590 Storage Management GroupEnclosure Management Module StateEnclosure Management Module SeverityEnclosure Management Module Part NumberName enclosure
Storage Management Group 591Enclosure Management Module TypeEnclosure Management Module Firmware VersionEnclosure Management Module Maximum SpeedName
592 Storage Management GroupEnclosure Management Module Roll-Up StatusEnclosure Management Module Component StatusName enclosureManagementModuleRollUp
Storage Management Group 593Enclosure Management Module Nexus IDEnclosure Management Module RevisionEnclosure Management Module Connection TableThis t
594 Storage Management GroupEnclosure Management Module Connection EntryEnclosure Management Module Connection NumberEnclosure Management Module Conne
Storage Management Group 595Enclosure Management Module Connection EMM NumberEnclosure Management Module Connection Enclosure NameEnclosure Management
596 Storage Management GroupBattery TableThis table describes available properties for each controller battery on the managed system.The following obj
Storage Management Group 597Battery NameBattery VendorBattery StateName batteryNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2Description Identifi
598 Storage Management GroupBattery Roll-Up StatusBattery Component StatusName batteryRollUpStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5Descr
Storage Management Group 599Battery Charge CountBattery Max Charge CountBattery Nexus IDName batteryChargeCountObject ID 1.3.6.1.4.1.674.10893.1.20.13
6 Contents6 Operating System Group . . . . . . . . . . . . 113Operating System Group Table . . . . . . . . . . . . . 113Operating System Table . .
60 System State GroupSystem State Cooling Unit Status CombinedSystem State Cooling Unit Status ListSystem State AC Power Switch Status CombinedName sy
600 Storage Management GroupBattery Predicted CapacityBattery Next Learn TimeName batteryPredictedCapacityObject ID 1.3.6.1.4.1.674.10893.1.20.130.15.
Storage Management Group 601Battery Learn StateBattery Maximum Learn DelayName batteryLearnStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12Descri
602 Storage Management GroupBattery Connection TableThis table describes the connection between each controller battery on the managed system and its
Storage Management Group 603Battery Connection Battery NameBattery Connection Battery NumberBattery Connection Controller NameBattery Connection Contr
604 Storage Management GroupLogical Devices GroupThe Logical Devices Management Information Base (MIB) group provides information about the logical de
Storage Management Group 605Virtual Disk EntryVirtual Disk NumberVirtual Disk NameVirtual Device Disk NameName virtualDiskEntryObject ID 1.3.6.1.4.1.6
606 Storage Management GroupVirtual Disk StateName virtualDiskStateObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4Description Identifies the current st
Storage Management Group 607Virtual Disk SeverityVirtual Disk Length in MegabytesVirtual Disk Length in BytesName virtualDiskSeverityObject ID 1.3.6.1
608 Storage Management GroupVirtual Disk Free Space in MegabytesVirtual Disk Free Space in BytesVirtual Disk Write PolicyName virtualDiskFreeSpaceInMB
Storage Management Group 609Virtual Disk Read PolicyVirtual Disk Cache PolicyName virtualDiskReadPolicyObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11
System State Group 61System State AC Power Switch Status ListSystem State Redundant Memory Unit Status CombinedSystem State Redundant Memory Unit Stat
610 Storage Management GroupVirtual Disk LayoutVirtual Disk Current Stripe Size in MegabytesName virtualDiskLayoutObject ID 1.3.6.1.4.1.674.10893.1.20
Storage Management Group 611Virtual Disk Current Stripe Size in BytesVirtual Disk ChannelVirtual Disk Target IDVirtual Disk LUN IDName virtualDiskCurS
612 Storage Management GroupVirtual Disk Roll-Up StatusVirtual Disk Component StatusName virtualDiskRollUpStatusObject ID 1.3.6.1.4.1.674.10893.1.20.1
Storage Management Group 613Virtual Disk Nexus IDVirtual Disk Array Disk TypeArray Disk Logical Connection TableThis table describes the connections b
614 Storage Management GroupArray Disk Logical Connection EntryArray Disk Logical Connection NumberArray Disk Logical Connection Array Disk NameName a
Storage Management Group 615Array Disk Logical Connection Array Disk NumberArray Disk Logical Connection Virtual Disk NameArray Disk Logical Connectio
616 Storage Management GroupArray Disk Logical Connection Disk NumberStorage Management Event GroupThe Storage Management Event Group defines the prop
Storage Management Group 617Location EventObject Name EventObject OID EventObject Nexus EventName locationEventObject ID 1.3.6.1.4.1.674.10893.1.20.20
618 Storage Management GroupCurrent Status EventPrevious Status EventName currentStatusEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.7Description Curr
Change Management Group 619Change Management GroupThe Change Management Group lets you monitor information about the Dell™ devices and software that a
62 System State GroupSystem State Processor Device Status CombinedSystem State Processor Device Status ListSystem State Battery Status CombinedName sy
620 Change Management GroupDevice GroupThe Device Group defines information about the devices discovered on the system during an inventory scan. Ident
Change Management Group 621Device Component IDDevice Display StringDevice Vendor IDDevice IDName deviceComponentIDObject ID 1.3.6.1.4.1.674.10899.1.5.
622 Change Management GroupDevice Sub IDDevice Sub Vendor IDApplication Group NOTE: Dell updateable components such as Basic input/output system (BIO
Change Management Group 623Application Group TableThe following object sets up the Application Group Table.Application EntryApplication IndexApplicati
624 Change Management GroupApplication Component TypeApplication VersionApplication Display StringApplication Sub-Component IDName applicationComponen
Change Management Group 625Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating sys
626 Change Management GroupOperating System Service Pack Major VersionOperating System Service Pack Minor VersionOperating System ArchitectureInventor
Change Management Group 627Product ID Display NameProduct ID DescriptionProduct ID VendorProduct ID VersionName productIDDisplayNameObject ID 1.3.6.1.
628 Change Management GroupProduct ID Build NumberName productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5Description Describes the software bu
Traps 629TrapsThe Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs.
System State Group 63System State Battery Status ListName systemStateBatteryStatusListObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.53Description Lists t
630 TrapsTrap VariablesThis section describes the variables that are sent to the management console to provide additional information about a trap or
Traps 631Current StatusPrevious StatusDataVariable Name alertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.1.5000.10.4Description Gives the current sta
632 TrapsUnderstanding the Trap DescriptionTable 25-1 lists in alphabetical order each line item that may appear in the trap description.Table 25-1. T
Traps 633Chassis intrusion state: <Intrusion state>Specifies the chassis intrusion state (open or closed), for example:Chassis intrusion state:
634 TrapsDiscrete voltage state: <State>Specifies the state of the voltage sensor, for example:Discrete voltage state: GoodFan sensor value: <
Traps 635Power Supply type: <type of power supply>Specifies the type of power supply, for example:Power Supply type: VRMPre-failure state was: &
636 TrapsUnderstanding Trap SeverityTraps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical co
Traps 637Table 25-2. Miscellaneous TrapsTrap IDDescription Severity CauseSystem Up1001 Server Administrator startup completeInformation Server Adminis
638 TrapsTemperature Probe TrapsTemperature probes help protect critical components by alerting the systems management console when temperatures becom
Traps 639Temperature Probe Warning1053 Temperature sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Na
64 System State Group
640 TrapsCooling Device TrapsCooling device traps monitor how well a fan is functioning.Temperature Probe Nonrecoverable1055 Temperature sensor detect
Traps 641Cooling Device Warning1103 Fan sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of chass
642 TrapsVoltage Probe TrapsVoltage probes monitor the number of volts across critical components.Table 25-5. Voltage Probe TrapsTrap ID Description S
Traps 643Voltage Probe Warning1153 Voltage sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of ch
644 TrapsAmperage Probe TrapsAmperage probes measure the amount of current (in amperes) that is traversing critical components.Voltage Probe Nonrecove
Traps 645Table 25-6. Amperage Probe TrapsTrap ID Description Severity CauseAmperage Probe Normal1202 Current sensor returned to a normal valueSensor l
646 TrapsAmperage Probe Failure1204 Current sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of c
Traps 647Chassis Intrusion TrapsChassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’
648 TrapsRedundancy Unit TrapsRedundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for ex
Traps 649Redundancy Degraded1305 Redundancy degradedRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis>Pr
Chassis Information Group 65Chassis Information GroupThe Chassis Information Group provides information about the type or types of chassis in your sys
650 TrapsPower Supply TrapsPower supply traps provide status and warning information for power supplies present in a particular chassis.Table 25-9. Po
Traps 651Power Supply Warning1353 Power supply detected a warningSensor location: <Location in chassis>Chassis location: <Name of chassis>
652 TrapsMemory Device TrapsMemory device messages provide status and warning information for memory modules present in a particular system. Memory de
Traps 653Table 25-10. Memory Device MessagesTrap ID Description Severity Cause1403 Memory device status is <status>Memory device location: <L
654 TrapsFan Enclosure TrapsSome systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures for whether foreign
Traps 655AC Power Cord TrapsThe AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and wa
656 TrapsHardware Log TrapsHardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is impl
Traps 657Processor Device Status TrapsThe BMC on some systems reports the status of processor devices. Processor device status traps provide status an
658 TrapsPluggable Device TrapsServer Administrator monitors the addition and removal of pluggable devices such as memory cards. Device traps provide
Traps 659Pluggable Device Removal1652 Device removed from systemDevice Location: <Location in chassis>Chassis Location: <Name of chassis>A
66 Chassis Information GroupChassis Information Table EntryChassis Index Chassis InformationChassis State CapabilitiesChassis State SettingsName chass
660 TrapsBattery TrapsThe BMC on some systems reports the status of batteries. Battery traps provide status and warning information for batteries pres
Traps 661RAC TrapsThis section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-s
662 TrapsTable 25-18. Enterprise-specific Traps Trap IDName Description Severity Category Cause Supported by RAC Platform1001 alertDrscTestTrapEventTh
Traps 6631004 alertDrscFoundESMThe RAC is communicating normally with the baseboard management controller (ESM)Information Error RAC recovered communi
664 Traps1007 alertDrscWatchdogExpiredThe RAC has detected that the system watchdog has expired indicating a system hangCritical Event RAC has detecte
Traps 6651010 alertDrscTempWarn in gThe RAC Temperature probe has detected a Warning valueMinor Status RAC temperature probe reading exceeded warning
666 Traps1015 alertDrscSELWarningThe RAC has detected a new event in the System Event Log with Severity: WarningMajor Error RAC detected a new system
Traps 667BMC TrapsThe BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and
668 Traps131841 Generic Critical Voltage Problem Critical131840 Generic Critical Voltage Problem ClearedInformational65792 Under-Temperature Warning (
Traps 669356096 Chassis Intrusion - Physical Security ViolationCritical356224 Chassis Intrusion (Physical Security Violation) Event ClearedInformation
Chassis Information Group 67Chassis StatusChassis Parent Index ReferenceChassis TypeChassis NameName chassisStatusObject ID 1.3.6.1.4.1.674.10892.1.30
670 Traps487298 CPU BIST (Built In Self Test) Failure ClearedInformational487176 CPU Disabled (Processor Disabled) Critical487304 CPU Enabled (Process
Traps 6712322178 ASR (Automatic System Recovery) Power Down OccurredCritical2322179 ASR (Automatic System Recovery) Power Cycle OccurredCriticalTable
672 Traps
Storage Management Alert Reference 673Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the he
674 Storage Management Alert Reference NOTE: You can also view these alerts in the Windows Event Viewer. Every alert consists of the following:• Seve
Storage Management Alert Reference 675SNMP Support for Storage Management Alerts By default, Storage Management installs SNMP trap forwarding support.
676 Storage Management Alert ReferenceSNMP Trap VariablesThe Storage Management SNMP traps use a set of variables that are included with every trap. T
Standard Data Type Definitions 677Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts a
678 Standard Data Type DefinitionsVariables with Data Types of State Capabilities and State Capabilities UniqueVariables with definitions of <varia
Standard Data Type Definitions 679enabled(2)The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).notReady(
68 Chassis Information GroupChassis Manufacturer NameChassis Model NameChassis Asset Tag NameChassis Service Tag NameName chassisManufacturerNameObjec
680 Standard Data Type DefinitionsDell Status Data TypesStatus data types include DellStatus, DellStatusRedundancy, and DellStatusProbe.Table A-5. Del
Standard Data Type Definitions 681Dell DateThe DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent ba
682 Standard Data Type DefinitionsFull Dates Full dates are defined in the ASCII format:yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where y
SNMP Sample Output 683SNMP Sample OutputThis sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Inst
684 SNMP Sample Output1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0'1.3.6.1.4.1.674.10892.1.100.11.0 = 01.3.6.1.4.1.674.10892.1.100.12.0 =
SNMP Sample Output 6851.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 31.3.6.1.4.1.674.10892.1.200.10.1.25.1 = '\03\03\03\03\03\03'1.3.6.1.4.1.6
686 SNMP Sample Output1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 2891.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 41.3.6.1.4.1.674.10892.1.300.10.1.15.1 =
SNMP Sample Output 6871.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 4801.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 11.3.6.1.4.1.674.10892.1.300.10.1.38.1 =
688 SNMP Sample Output
Glossary 689GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in Dell™ user documents.AAbbreviation f
Chassis Information Group 69Chassis IDChassis ID ExtensionChassis System ClassChassis System NameName chassisIDObject ID 1.3.6.1.4.1.674.10892.1.300.1
690 GlossaryASICAcronym for application-specific integrated circuit.ASPIAdvanced SCSI programming interface.ASRAbbreviation for automatic system recov
Glossary 691BGAAbbreviation for Ball Grid Array, an IC package that uses an array of solder balls, instead of pins, to connect to a PC board.binaryA b
692 GlossarybpsAbbreviation for bits per second.BTUAbbreviation for British thermal unit.busAn information pathway between the components of a compute
Glossary 693chipA set of microminiaturized, electronic circuits that are designed for use as processors and memory in computers. Small chips can hold
694 Glossaryconfig.sys fileThe config.sys file is executed when you boot your computer (before running any commands in the autoexec.bat file). This st
Glossary 695cursorA marker, such as a block, underscore, or pointer that represents the position at which the next keyboard or mouse action will occur
696 GlossarydirectoryDirectories help keep related files organized on a disk in a hierarchical, "inverted tree" structure. Each disk has a &
Glossary 697DRAMAcronym for dynamic random-access memory. A computer’s RAM is usually made up entirely of DRAM chips. Because DRAM chips cannot store
698 GlossaryEIDEAbbreviation for enhanced integrated drive electronics. EIDE devices add one or more of the following enhancements to the traditional
Glossary 699ESDAbbreviation for electrostatic discharge.ESMAbbreviation for Embedded Systems Management.expanded memoryA technique for accessing RAM a
Contents 79 Thermal Group . . . . . . . . . . . . . . . . . . . 181Thermal Group Tables . . . . . . . . . . . . . . . . . . 181Cooling Unit Table .
70 Chassis Information GroupChassis System Boot Date NameChassis System Date NameChassis System Location NameChassis System Primary User NameName chas
700 GlossaryFEPROMAcronym for Flash Erasable Programmable Read-Only Memory. Flash memory is a kind of non-volatile storage device similar to EEPROM, b
Glossary 701graphics coprocessorSee coprocessor.graphics modeA video mode that can be defined as x horizontal by yvertical pixels by z colors.groupAs
702 Glossaryhot plugThe ability to remove and replace a redundant part while the system is being used. Also called a "hot spare."HPFSAbbrevi
Glossary 703internal microprocessor cacheAn instruction and data cache built in to the microprocessor. The Intel Pentium microprocessor includes a 16-
704 GlossaryKAbbreviation for kilo-, indicating 1,000.KBAbbreviation for kilobyte(s), 1,024 bytes.KB/secAbbreviation for kilobyte(s) per second.Kbit(s
Glossary 705LEDAbbreviation for light-emitting diode. An electronic device that lights up when a current is passed through it.local busOn a computer w
706 GlossaryMbpsAbbreviation for megabits per second.MBRAbbreviation for master boot record.MCAAbbreviation for Micro Channel Architecture, which is d
Glossary 707MIDIAbbreviation for musical instrument digital interface.MIFAcronym for management information format. A MIF file contains information, s
708 GlossarymVAbbreviation for millivolt(s).nameThe name of an object or variable is the exact string that identifies it in an SNMP Management Informa
Glossary 709OIDAbbreviation for object identifier. An implementation-specific integer or pointer that uniquely identifies an object.online access serv
Chassis Information Group 71Chassis System User Phone Number NameChassis Connection Status UniqueChassis Fan Control Capabilities UniqueChassis Fan Co
710 GlossaryPCIAbbreviation for Peripheral Component Interconnect. A standard for local-bus implementation developed by Intel Corporation.PCIXAbbrevia
Glossary 711pixelA single point on a video display. Pixels are arranged in rows and columns to create an image. A video resolution, such as 640 x 480,
712 Glossaryprotected modeAn operating mode supported by 80286 or higher microprocessors, protected mode allows operating systems to implement:• A mem
Glossary 713RAWUnprocessed. The term refers to data that is passed along to an I/O device without being interpreted. In contrast, cooked refers to dat
714 Glossaryrefresh rateThe rate at which the monitor redraws the video image on the monitor screen. More precisely, the refresh rate is the frequency
Glossary 715SCSIAcronym for small computer system interface. An I/O bus interface with faster data transmission rates than standard ports. You can con
716 GlossarySIMDAbbreviation for Single Instruction Multiple Data.SIMMAcronym for single in-line memory module. A small circuit board containing DRAM
Glossary 717SOJAcronym for small outline package J-lead, a small-dimension, plastic, rectangular surface mount chip package with j-shaped pins on its
718 Glossarysystem boardAs the main circuit board, the system board usually contains most of your computer’s integral components, such as the followin
Glossary 719tableIn SNMP MIBs, a table is a two dimensional array that describes the variables that make up a managed object.TCP/IPAbbreviation for Tr
72 Chassis Information GroupChassis LED Control Capabilities UniqueChassis LED Control Settings UniqueChassis Hard-Drive (HD) Fault Clear Control Capa
720 Glossarytime-outA specified period of system inactivity that must occur before an energy conservation feature is activated.tpiAbbreviation for tra
Glossary 721unicodeA fixed width, 16-bit world wide character encoding, developed and maintained by the Unicode Consortium.upper memory areaThe 384 KB
722 GlossaryvariableA component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or stat
Glossary 723video adapterThe logical circuitry that provides—in combination with the monitor—your computer’s video capabilities. A video adapter may s
724 Glossaryvirtual memoryA method for increasing addressable RAM by using the hard drive. For example, in a computer with 16 MB of RAM and 16 MB of v
Glossary 725Wakeup on LANThe ability for the power in a client station to be turned on by the network. Remote wake-up enables software upgrading and o
726 GlossaryXMSAbbreviation for eXtended Memory Specification.ZIFAcronym for zero insertion force. Some computers use ZIF sockets and connectors to al
Index 727IndexNumerics1403, 6531404, 6531602, 6571603, 6571604, 6581651, 6581652, 6591653, 659AApplication, 622Application Group, 622BBIOS GroupBIOS S
728 IndexCOO Support Information Table, 420COO Trouble Ticket Table, 422COO Warranty Table, 408Cost of Ownership Table, 393Cost of Ownership tables, 3
Index 729MMemory device correction rate crossed a warning threshold, 653Memory device ECC Correctable error count crossed a warning threshold, 653Memo
Chassis Information Group 73Chassis Identify Flash Control CapabilitiesChassis Identify Flash Control SettingsChassis Lock PresentChassis Host Control
730 IndexRRedundant Memory Unit Table, 337Remote Access GroupRemote Access Table, 434Remote SNMP Trap Table, 451Remote User Administration Table, 443R
Index 731trap variables, 630current status, 631data, 631message, 630previous status, 631system, 630table index OID, 630traps, 636AC power cord traps,
732 Index
74 Chassis Information GroupChassis Host Control Settings UniqueChassis Watchdog Control Capabilities UniqueChassis Watchdog Control Settings UniqueCh
Chassis Information Group 75Chassis Watchdog Control Expiry TimeChassis Allow Set Commands From SNMPChassis Power Button Control Capabilities UniqueNa
76 Chassis Information GroupChassis Power Button Control Settings UniqueChassis Reseller NameChassis Reseller Contact Information NameChassis Reseller
Chassis Information Group 77Chassis Reseller System IDChassis NMI Button Control Capabilities UniqueChassis NMI Button Control Settings UniqueUUID Tab
78 Chassis Information GroupUUID Table EntryUUID Chassis IndexUUID IndexUUID TypeName uUIDTableEntryObject ID 1.3.6.1.4.1.674.10892.1.300.20.1Descript
Chassis Information Group 79UUID ValuePOST Log TableThis section defines attributes for the power-on self-test (POST) log. When you turn on your compu
8 Contents13 Device Group . . . . . . . . . . . . . . . . . . . . . 243Device Tables . . . . . . . . . . . . . . . . . . . . . . 243Pointing Device
80 Chassis Information GroupPOST Log Chassis IndexPOST Log Record IndexPOST Log State Capabilities UniquePOST Log State Settings UniqueName postLogcha
Chassis Information Group 81POST Log RecordPOST Log FormatEvent Log TableEvent Log Table EntryName postLogRecordObject ID 1.3.6.1.4.1.674.10892.1.300.
82 Chassis Information GroupEvent Log Chassis IndexEvent Log Record IndexEvent Log State Capabilities UniqueEvent Log State Settings UniqueName eventL
Chassis Information Group 83Event Log RecordEvent Log FormatEvent Log Severity StatusEvent Log Date NameName eventLogRecordObject ID 1.3.6.1.4.1.674.1
84 Chassis Information GroupSystem BIOS TableThis table lists objects that define the system’s basic input/output system (BIOS).System BIOS Table Entr
Chassis Information Group 85System BIOS State CapabilitiesSystem BIOS State SettingsSystem BIOS StatusSystem BIOS SizeName systemBIOSStateCapabilities
86 Chassis Information GroupSystem BIOS Release Date NameSystem BIOS Version NameSystem BIOS Starting AddressSystem BIOS Ending AddressName systemBIOS
Chassis Information Group 87System BIOS Manufacturer NameSystem BIOS CharacteristicsName systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.
88 Chassis Information GroupDescription Bit Position Meaning if Set-------------- ------------------Bit 16Selectable Boot is supportedBit 17BIOS RO
Chassis Information Group 89System BIOS Characteristics Ext 1System BIOS Characteristics Ext 2Name systemBIOSCharacteristicsExt1Object ID 1.3.6.1.4.1.
Contents 916 BIOS Setup Control Group . . . . . . . . . . 349BIOS Group Tables . . . . . . . . . . . . . . . . . . . 349BIOS Setup Control Table .
90 Chassis Information GroupFirmware TableFirmware Table EntryFirmware Chassis IndexFirmware IndexName firmwareTableObject ID 1.3.6.1.4.1.674.10892.1.
Chassis Information Group 91Firmware State CapabilitiesFirmware State CapabilitiesFirmware StatusFirmware SizeName firmwareStateCapabilitiesObject ID
92 Chassis Information GroupFirmware TypeFirmware Type NameFirmware Update CapabilitiesFirmware Date NameName firmwareTypeObject ID 1.3.6.1.4.1.674.10
Chassis Information Group 93Firmware Version NameIntrusion TableThe following objects and attributes describe the different forms of chassis intrusion
94 Chassis Information GroupIntrusion IndexIntrusion State CapabilitiesIntrusion State SettingsIntrusion StatusName intrusionIndexObject ID 1.3.6.1.4.
Chassis Information Group 95Intrusion ReadingIntrusion TypeIntrusion Location NameBaseboard TableThis table lists objects that define the baseboard of
96 Chassis Information GroupBaseboard Table EntryBaseboard Chassis IndexBaseboard IndexBaseboard State CapabilitiesName baseBoardTableEntryObject ID 1
Chassis Information Group 97Baseboard State SettingsBaseboard StatusBaseboard Feature FlagsBaseboard TypeName baseBoardStateSettings Object ID 1.3.6.1
98 Chassis Information GroupBaseboard Type NameBaseboard Location NameBaseboard Manufacturer NameBaseboard Product NameName baseBoardTypeNameObject ID
Chassis Information Group 99Baseboard Version NameBaseboard Service Tag NameBaseboard Piece Part ID (PPID) NameBaseboard Asset Tag NameName baseBoardV
Kommentare zu diesen Handbüchern