Dell OpenManage Server Administrator Version 5.4 Betriebsanweisung Seite 635

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 732
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 634
Traps 635
Power Supply type:
<type of power supply>
Specifies the type of power supply, for example:
Power Supply type: VRM
Pre-failure state was:
<State>
Specifies the status of the previous memory
message, for example:
Pre-failure state was: Failed
Previous redundancy
state was: <State>
Specifies the status of the previous redundancy
message, for example:
Previous redundancy state was:
Lost
Previous state was:
<State>
Specifies the previous state of the sensor, for
example:
Previous state was: OK (Normal)
Processor sensor
status:
<status>
Specifies the status of the processor sensor, for
example:
Processor sensor status:
Configuration error
Redundancy unit:
<Redundancy location in
chassis>
Specifies the location of the redundant power
supply or cooling unit in the chassis, for
example:
Redundancy unit: Fan Enclosure
Sensor location:
<Location in chassis>
Specifies the location of the sensor in the
specified chassis, for example:
Sensor location: CPU1
Temperature sensor
value (in degrees
Celsius):
<Reading>
Specifies the temperature in degrees Celsius,
for example:
Temperature sensor value (in
degrees Celsius): 30
Voltage sensor value
(in Volts):
<Reading>
Specifies the voltage sensor value in volts, for
example:
Voltage sensor value: 1.693
Table 25-1. Trap Description Reference (continued)
Description Line Item Explanation
Seitenansicht 634
1 2 ... 630 631 632 633 634 635 636 637 638 639 640 ... 731 732

Kommentare zu diesen Handbüchern

Keine Kommentare