710 Traps
Power Supply Traps
Power supply traps provide status and warning information for power supplies
present in a particular chassis.
Table 27-9. Power Supply Traps
TrapID Description Severity Cause
Power Supply Normal
1352 Power supply returned to normal
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Power Supply type:
<type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type: <type
of configuration error>
Information A power supply has been
reconnected or replaced.
The sensor location, chassis
location, previous state, and
additional information
about the power supply
event are provided.
Power Supply Warning
1353 Power supply detected a warning
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Power Supply type: <type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type: <type
of configuration error>
Warning A power supply sensor has
detected a warning
condition. The sensor
location, chassis location,
previous state, and
additional power supply
status information are
provided.