Dell OpenManage Server Administrator Version 7.0 Betriebsanweisung Seite 652

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 804
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 651
652 Storage Management Group
Battery Predicted Capacity
Battery Next Learn Time
Name batteryPredictedCapacity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be
replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge
capacity of the battery cannot be determined until the Learn cycle
is complete.
Syntax Integer
Access Read-only
Name batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be
executed
Syntax Integer
Access Read-only
book.book Page 652 Tuesday, February 28, 2012 2:19 PM
Seitenansicht 651
1 2 ... 647 648 649 650 651 652 653 654 655 656 657 ... 803 804

Kommentare zu diesen Handbüchern

Keine Kommentare