www.dell.com | support.dell.comDell™ OpenManage™Server Administrator Version 6.1Messages Reference Guide
10 IntroductionServer Administrator generates events based on status changes in the following sensors:•Temperature Sensor — Helps protect critical com
100 Storage Management Message Reference2087 Copy of data resumed from physical disk %2 to physical disk %1 OK / Normal / InformationalCause: This ale
Storage Management Message Reference 1012090Virtual disk reconfigu-ration completedOK / Normal / InformationalCause: This alert is for informational p
102 Storage Management Message Reference2094 Predictive Failure reported. Warning / Non-criticalCause: The physical disk is predicted to fail. Many ph
Storage Management Message Reference 1032094 cond.If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the
104 Storage Management Message Reference2098 Global hot spare assignedOK / Normal / InformationalCause: A user has assigned a physical disk as a globa
Storage Management Message Reference 1052100 Temp-erature exceeded the maximum warning thresholdWarning / Non-criticalCause: The physical disk enclosu
106 Storage Management Message Reference2101 Temperature dropped below the minimum warning thresholdWarning / Non-criticalCause: The physical disk enc
Storage Management Message Reference 1072103 Temperature dropped below the minimum failure threshold Critical / Failure / ErrorCause: The physical dis
108 Storage Management Message Reference2106 Smart FPT exceededWarning / Non-criticalCause: A disk on the specified controller has received a SMART al
Storage Management Message Reference 1092107 Smart configuration changeCritical / Failure / ErrorCause: A disk has received a SMART alert (predictive
Introduction 11•Processor Sensor — Monitors the processor status in the system.•Pluggable Device Sensor — Monitors the addition, removal, or configura
110 Storage Management Message Reference2108 Smart warningWarning / Non-criticalCause: A disk has received a SMART alert (predictive failure). The dis
Storage Management Message Reference 1112109 SMART warning temperatureWarning / Non-criticalCause: A disk has reached an unacceptable temperature and
112 Storage Management Message Reference2109 contdMake sure the enclosure has enough ventilation and that the room temperature is not too hot. See the
Storage Management Message Reference 1132110 SMART warning degradedWarning / Non-criticalCause: A disk is degraded and has received a SMART alert (pre
114 Storage Management Message Reference2112 Enclosure was shut downCritical / Failure / ErrorCause: The physical disk enclosure is either hotter or c
Storage Management Message Reference 1152114 A consistency check on a virtual disk has been paused (suspended)OK / Normal / InformationalCause: The ch
116 Storage Management Message Reference2116 A virtual disk and its mirror have been splitOK / Normal / InformationalCause: A user has caused a mirro
Storage Management Message Reference 1172118 Change write policyOK / Normal / InformationalCause: A user has changed the write policy for a virtual di
118 Storage Management Message Reference2121 Device returned to normalOK / Normal / InformationalCause: A device that was previously in an error state
Storage Management Message Reference 1192122 Redundancy degradedWarning / Non-criticalCause: One or more of the enclosure components has failed. For e
12 IntroductionThe location of the event log file depends on the operating system you are using.• In the Microsoft® Windows® 2000 Advanced Server and
120 Storage Management Message Reference2122 contd.The controller status displayed on the Health subtab indicates whether a controller has a failed or
Storage Management Message Reference 1212123 Redundancy lostWarning / Non-criticalCause: A virtual disk or an enclosure has lost data redundancy. In t
122 Storage Management Message Reference2123 contd.The controller status displayed on the Health subtab indicates whether a controller has a failed or
Storage Management Message Reference 1232124 Redundancy normal OK / Normal / InformationalCause: Data redundancy has been restored to a virtual disk o
124 Storage Management Message Reference2126 SCSI sense sector reassignWarning / Non-criticalCause: A sector of the physical disk is corrupted and dat
Storage Management Message Reference 1252127 Background initialization (BGI) startedOK / Normal / InformationalCause: BGI of a virtual disk has starte
126 Storage Management Message Reference2131 Firmware version mismatchWarning / Non-criticalCause: The firmware on the controller is not a supported v
Storage Management Message Reference 1272135 Array Manager is installed on the systemNOTE: This is not supported on Dell OpenManage Server Administrat
128 Storage Management Message Reference2137 Communica-tion timeoutWarning / Non-criticalCause: The controller is unable to communicate with an enclos
Storage Management Message Reference 1292137contd.Action: Check for problems with the cables. See the online help for more information on checking the
Introduction 133In the Event Viewer window, click the Tree tab and then click System Log.The System Log window displays a list of recently logged even
130 Storage Management Message Reference2139 Enclosure alarm disabledOK / Normal / InformationalCause: A user has disabled the enclosure alarm.Action:
Storage Management Message Reference 1312142 Controller rebuild rate has changedOK / Normal / InformationalCause: A user has changed the controller r
132 Storage Management Message Reference2145 Controller battery lowWarning / Non-criticalCause: The controller battery charge is low.Action: Reconditi
Storage Management Message Reference 1332148 Bad block medium errorWarning / Non-criticalCause: A portion of a physical disk is damaged.Action: See th
134 Storage Management Message Reference2151 Enclosure asset tag changedOK / Normal / InformationalCause: A user has changed the enclosure asset tag.
Storage Management Message Reference 1352154 Maximum temperature probe warning threshold value changedOK / Normal / InformationalCause: A user has cha
136 Storage Management Message Reference2158 Physical disk onlineOK / Normal / InformationalCause: An offline physical disk has been made online. This
Storage Management Message Reference 1372159 Virtual disk renamedOK / Normal / InformationalCause: A user has renamed a virtual disk. When renaming a
138 Storage Management Message Reference2163 Rebuild completed with errorsCritical / Failure / ErrorCause: You might be attempting a RAID configuratio
Storage Management Message Reference 1392165 The RAID controller firmware and driver validation was not performed. The configuration file cannot be op
14 Introductionchassis intrusion Chassis location: Main System Chassis Previous state was: Critical (Failed) Chassis intrusion state: ClosedViewing Ev
140 Storage Management Message Reference2167 The current kernel version and the non-RAID SCSI driver version are older than the minimum required level
Storage Management Message Reference 1412168 The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validat
142 Storage Management Message Reference2170 The controller battery charge level is normal.OK / Normal / InformationalCause: This alert is for informa
Storage Management Message Reference 1432172 The controller battery temperature is normal.OK / Normal / InformationalCause: This alert is for informat
144 Storage Management Message Reference2174 The controller battery has been removed.Warning / Non-criticalCause: The controller cannot communicate wi
Storage Management Message Reference 1452176 The controller battery Learn cycle has started.OK / Normal / InformationalCause: This alert is for inform
146 Storage Management Message Reference2178 The controller battery Learn cycle has timed out.Warning / Non-criticalCause: The controller battery must
Storage Management Message Reference 1472180 The controller battery Learn cycle will start in %1 days. OK / Normal / InformationalCause: This alert is
148 Storage Management Message Reference2183 Replace member operation failed on physical disk %1Critical / Failure / ErrorCause: The physical disk bei
Storage Management Message Reference 1492186 The controller cache has been discarded.Warning / Non-criticalCause: The controller has flushed the cache
Introduction 15Table 1-2. Event Description ReferenceDescription Line Item ExplanationAction performed was: <Action>Specifies the action that wa
150 Storage Management Message Reference2188 The controller write policy has been changed to Write Through.OK / Normal / InformationalCause: The contr
Storage Management Message Reference 1512190 The controller has detected a hot-plugged enclosure.OK / Normal / InformationalCause: The SAS controller
152 Storage Management Message Reference2192 The virtual disk Check Consistency has made corrections.OK / Normal / InformationalCause: The virtual dis
Storage Management Message Reference 1532194 The virtual disk Read policy has changed.OK / Normal / InformationalCause: This alert is for informationa
154 Storage Management Message Reference2197 Replace member operation has stopped for rebuild. OK / Normal / InformationalCause: This alert is provide
Storage Management Message Reference 1552200 Replace operation is not possible, because the physical disk type or bus protocol is different from the v
156 Storage Management Message Reference2202 A global hot spare has been removed.OK / Normal / InformationalCause: The controller is unable to communi
Storage Management Message Reference 1572204 A dedicated hot spare has been removed.OK / Normal / InformationalCause: The controller is unable to comm
158 Storage Management Message Reference2211 The physical disk is not supported.Warning / Non-criticalCause: The physical disk may not have a supporte
Storage Management Message Reference 1592214 Battery charge in progressOK / Normal / InformationalCause: This alert is for informational purposes. Act
16 IntroductionDevice location: <Location in chassis>Specifies the location of the device in the specified chassis, for example: Device location
160 Storage Management Message Reference2218 None of the Controller Property are changed.OK / Normal / InformationalCause: This alert is for informati
Storage Management Message Reference 1612221 Auto Replace Member operation on Predictive Failure, Abort Check Consistency on Error, and Load balance c
162 Storage Management Message Reference2224 Allow Revertible Hot Spare and Replace Member and Load balance changed.OK / Normal / InformationalCause:
Storage Management Message Reference 1632227 Abort Check Consistency on Error, Allow Revertible Hot Spare and Replace Member, and Auto Replace Member
164 Storage Management Message Reference2230 Auto Replace Member operation on Predictive Failure changed.OK / Normal / InformationalCause: This alert
Storage Management Message Reference 1652234 The Patrol Read rate has changed.OK / Normal / InformationalCause: This alert is for informational purpos
166 Storage Management Message Reference2238 The controller debug log file has been exported.OK / Normal / InformationalCause: The user has attempted
Storage Management Message Reference 1672242 The Patrol Read has started.OK / Normal / InformationalCause: The controller has started the Petrol Read
168 Storage Management Message Reference2245 A virtual disk blink has ceased.OK / Normal / InformationalCause: This alert is for informational purpose
Storage Management Message Reference 1692248 The controller battery is executing a Learn cycle.OK / Normal / InformationalCause: This alert is for inf
Introduction 17Possible memory module event cause: <list of causes>Specifies a list of possible causes for the memory module event, for example:
170 Storage Management Message Reference2251 The physical disk blink has initiated.OK / Normal / InformationalCause: This alert is for informational p
Storage Management Message Reference 1712254 The Clear operation has cancelled.OK / Normal / InformationalCause: This alert is for informational purpo
172 Storage Management Message Reference2258 Controller has preserved cacheWarning /Non-criticalCause: IO interrupted for a virtual disk which is con
Storage Management Message Reference 1732261 A global rescan has initiated.OK / Normal / InformationalCause: This alert is for informational purposes.
174 Storage Management Message Reference2264 A device is missing.Warning / Non-criticalCause: The controller cannot communicate with a device. The dev
Storage Management Message Reference 1752265 A device is in an unknown state.Warning / Non-criticalCause: The controller cannot communicate with a dev
176 Storage Management Message Reference2266 Controller log file entry: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable.
Storage Management Message Reference 1772268 %1, Storage Manage-ment has lost communication with the controller. An immediate reboot is strongly recom
178 Storage Management Message Reference2270 The physical disk Clear operation failed.Critical / Failure / ErrorCause: A Clear task was being performe
Storage Management Message Reference 1792272 Patrol Read found an uncorrectable media error.Critical / Failure / ErrorCause: The Patrol Read task has
18 Introduction
180 Storage Management Message Reference2273 A block on the physical disk has been punctured by the controller.Critical / Failure / ErrorCause: The co
Storage Management Message Reference 1812276 The dedicated hot spare is too small.Warning / Non-criticalCause: The dedicated hot spare is not large en
182 Storage Management Message Reference2278 The controller battery charge level is below a normal threshold.OK / Normal / InformationalCause: The bat
Storage Management Message Reference 1832280 A disk media error has been corrected.OK / Normal / InformationalCause: A disk media error was detected w
184 Storage Management Message Reference2282 Hot spare SMART polling failed.Critical / Failure / ErrorCause: The controller firmware attempted a SMART
Storage Management Message Reference 1852286 A Learn cycle start is pending while the battery charges.OK / Normal / InformationalCause: This alert is
186 Storage Management Message Reference2289 Multi-bit ECC error.Critical / Failure / ErrorCause: An error involving multiple bits has been encountere
Storage Management Message Reference 1872290 Single-bit ECC error.Warning / Non-criticalCause: An error involving a single bit has been encountered du
188 Storage Management Message Reference2293 The EMM has failed.Critical / Failure / ErrorCause: The failure may be caused by a loss of power to the E
Storage Management Message Reference 1892296 An EMM has been inserted.OK / Normal / InformationalCause: This alert is for informational purposes. Acti
Event Message Reference 19Event Message ReferenceThe following tables lists in numerical order each event ID and its corresponding description, along
190 Storage Management Message Reference2298 There is a bad sensor on an enclosure.Warning / Non-criticalCause: The enclosure has a bad sensor. The en
Storage Management Message Reference 1912300 The enclosure is unstable.Critical / Failure / ErrorCause: The controller is not receiving a consistent r
192 Storage Management Message Reference2301 The enclosure has a hardware error.Critical / Failure / ErrorCause: The enclosure or an enclosure compone
Storage Management Message Reference 1932303 The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled.OK / Normal
194 Storage Management Message Reference2305 The physical disk is too small to be used for a rebuild.Warning / Non-criticalCause: The physical disk is
Storage Management Message Reference 1952306 Bad block table is 80% full.Warning / Non-criticalCause: The bad block table is used for remapping bad di
196 Storage Management Message Reference2307 Bad block table is full. Unable to log block %1Critical / Failure / ErrorCause: The bad block table is us
Storage Management Message Reference 1972309 A physical disk is incopatible.Warning / Non-criticalCause: You have attempted to replace a disk with ano
198 Storage Management Message Reference2311 The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2Warning / Non-criticalCause: The firmwar
Storage Management Message Reference 1992313 A power supply in the enclosure has a DC failure.Warning / Non-criticalCause: The power supply has a DC f
Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potenti
20 Event Message Reference1004 Thermal shutdown protection has been initiatedError This message is generated when a system is configured for thermal s
200 Storage Management Message Reference2315 Diagnostic message %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text
Storage Management Message Reference 2012318 Problems with the battery or the battery charger have been detected. The battery health is poor.Warning /
202 Storage Management Message Reference2320 Single-bit ECC error. The DIMM is critically degraded.Critical / Failure / ErrorCause: The DIMM is malfun
Storage Management Message Reference 2032322 The DC power supply is switched off.Critical / Failure / ErrorCause: The power supply unit is switched of
204 Storage Management Message Reference2324 The AC power supply cable has been removed.Critical / Failure / ErrorCause: The power cable may be pulled
Storage Management Message Reference 2052326 A foreign configuration has been detected.OK / Normal / InformationalCause: This alert is for information
206 Storage Management Message Reference2327 The NVRAM has corrupted data. The controller is reinitializing the NVRAM.Warning / Non-criticalCause: The
Storage Management Message Reference 2072329 SAS port report: %1Warning / Non-criticalCause: The text for this alert is generated by the controller an
208 Storage Management Message Reference2330 SAS port report: %1OK / Normal / InformationalCause: The %1 indicates a substitution variable. The text
Storage Management Message Reference 2092332 A controller hot plug has been detected.OK / Normal / InformationalCause: This alert is for informational
Event Message Reference 211008 Systems Management Data Manager StartedInformation Systems Management Data Manager services were started.1009 Systems M
210 Storage Management Message Reference2335 Controller event log: %1Warning / Non-criticalCause: The %1 indicates a substitution variable. The text f
Storage Management Message Reference 2112336 Controller event log: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The te
212 Storage Management Message Reference2337 The controller is unable to recover cached data from the battery backup unit (BBU).Critical / Failure / E
Storage Management Message Reference 2132339 The factory default settings have been restored.OK / Normal / InformationalCause: This alert is for infor
214 Storage Management Message Reference2341 The Check Consistency made corrections and completed.OK / Normal / InformationalCause: This alert is for
Storage Management Message Reference 2152343 The Check Consistency logging of inconsistent parity data is disabled.Warning / Non-criticalCause: The Ch
216 Storage Management Message Reference2347 The rebuild failed due to errors on the source physical disk.Critical / Failure / ErrorCause: You are att
Storage Management Message Reference 2172350 There was an unrecoverable disk media error during the rebuild.Critical / Failure / ErrorCause: The rebui
218 Storage Management Message Reference2352 A physical disk that was marked as missing has been replaced.OK / Normal / InformationalCause: This alert
Storage Management Message Reference 2192356 SAS SMP communications error %1.Critical / Failure / ErrorCause: The %1 indicates a substitution variable
22 Event Message ReferenceTemperature Sensor MessagesTemperature sensors listed in Table 2-2 help protect critical components by alerting the systems
220 Storage Management Message Reference2357 SAS expander error: %1Critical / Failure / ErrorCause: The %1 indicates a substitution variable. The text
Storage Management Message Reference 2212359 The physical disk is not certified.Warning / Non-criticalCause: The physical disk does not comply with th
222 Storage Management Message Reference2362 Physical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state during t
Storage Management Message Reference 2232367 Rebuild is not possible because mixing of different media type (SSD/HDD) and bus protocols (SATA/SAS) is
224 Storage Management Message Reference2369 Virtual Disk Redundancy has been degraded.OK / Normal / InformationalCause: A physical disk in a RAID 6 v
Storage Management Message Reference 2252372 Attempted import of Virtual Disk exceeding the limit supported on the controller.OK / Normal / Informatio
226 Storage Management Message Reference2375 Attempted import of Virtual Disk with missing physical diskOK / Normal / InformationalCause: User is atte
Storage Management Message Reference 2272378 Attempted import of an incompatible physical driveOK / Normal / InformationalCause: User is attempting to
228 Storage Management Message Reference2381 Controller preserved cache is recovered.OK / Normal / InformationalCause: This alert is provided for info
Storage Management Message Reference 2292383 The Information level set for the hot spare protection policy is violated for the Virtual Disk.OK / Norma
Event Message Reference 231052 Temperature sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of
230 Storage Management Message Reference2385 The Critical level set for the hot spare protection policy is violated for the Virtual Disk.Critical / Fa
Index 231IndexSymbols%1, Storage Management has lost communication with this RAID controller and attached storage. An immediate reboot is strongly rec
232 Index1204, 321205, 331250, 341251, 341252, 341253, 351254, 351255, 351300, 361301, 361302, 371303, 371304, 371305, 381306, 381350, 391351, 391352,
Index 2331703, 541704, 541705, 542000, 552002, 552003, 552004, 552005, 552048, 852049, 862050, 872051, 872052, 882053, 882054, 882055, 892056, 892057,
234 Index2105, 1072106, 1082107, 1092108, 1102109, 1112110, 1132111, 1132112, 1142114, 1152115, 1152116, 1162117, 1162118, 1172120, 1172121, 1182122,
Index 2352165, 1392166, 1392167, 1402168, 1412169, 1412170, 1422171, 1422173, 1432174, 1442175, 1442176, 1452177, 1452178, 1462179, 1462180, 1472181,
236 Index2224, 1622226, 1622227, 1632228, 1632229, 1632230, 1642231, 1642232, 1642233, 1642234, 1652235, 1652236, 1652237, 1652238, 1662239, 1662240,
Index 2372285, 1842286, 1852287, 1852288, 1852289, 1862290, 1872291, 1872292, 1872293, 1882294, 1882295, 1882296, 1892297, 1892298, 1902299, 1902300,
238 Index2342, 2142343, 2152346, 2152347, 2162348, 2162349, 2162350, 2172351, 2172352, 2182353, 2182356, 2192357, 2202358, 2202359, 2212360, 2212361,
Index 239A controller rescan has been initiated., 165A dedicated hot spare failed., 156A dedicated hot spare has been automatically unassigned., 157A
24 Event Message Reference1054 Temperature sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of ch
240 IndexAC power cord sensor, 10AC power cord sensor has failed, 45, 67AC power has been lost, 46AC power has been restored, 45All virtual disks are
Index 241Ccable interconnect messages, 76Change write policy, 117Chassis intrusion detected, 35, 63Chassis intrusion in progress, 35, 63chassis intrus
242 IndexDedicated hot spare unassigned. Physical disk %1, 153Dedicated spare imported as global due to missing arrays, 222Device failed, 85Device ret
Index 243GGlobal hot spare assigned, 104Global hot spare unassigned, 104Hhardware log sensor, 10Hardware Log Sensor Events, 66hardware log sensor mess
244 Indexintrusion, 68memory device, 42memory ecc, 64memory modules, 65miscellaneous, 19pluggable device, 51, 69power supply, 38, 62processor sensor,
Index 245power supply messages, 38, 62Power supply returned to normal, 40, 65power supply sensor, 10Power supply sensor detected a non-recoverable val
246 IndexSee the Readme file for a list of validated controller driver versions, 138sensorAC power cord, 10chassis intrusion, 10current, 10fan, 10fan
Index 247Temperature sensor detected a non-recoverable value, 24Temperature sensor detected a warning value, 23Temperature Sensor Events, 57Temperatur
248 IndexThe controller battery Learn cycle will start in % days., 147The controller battery needs to be replaced., 141The controller battery temperat
Index 249The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible., 199The non-RAID S
Event Message Reference 25Cooling Device MessagesCooling device sensors listed in Table 2-3 monitor how well a fan is functioning. Cooling device mess
250 IndexThe rebuild failed due to errors on the target physical disk., 216The SCSI Enclosure Processor (SEP) has been rebooted as part of the firmwar
Index 251Virtual disk deleted, 88Virtual disk failed, 89Virtual disk format changed, 97Virtual disk format completed, 99Virtual disk format started, 9
Index 252
26 Event Message Reference1103 Fan sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of chassis>
Event Message Reference 27Voltage Sensor MessagesVoltage sensors listed in Table 2-4 monitor the number of volts across critical components. Voltage s
28 Event Message Reference1152 Voltage sensor returned to a normal valueSensor location: <Location in chassis>Chassis location: <Name of chas
Event Message Reference 291154 Voltage sensor detected a failure valueSensor location: <Location in chassis>Chassis location: <Name of chassi
Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 7What’s New in this Release . . . . . . . . . . . . . . . . 8Messa
30 Event Message ReferenceCurrent Sensor MessagesCurrent sensors listed in Table 2-5 measure the amount of current (in amperes) that is traversing cri
Event Message Reference 311201 Current sensor value unknownSensor location: <Location in chassis>Chassis location: <Name of chassis>Previo
32 Event Message Reference1203 Current sensor detected a warning valueSensor location: <Location in chassis>Chassis location: <Name of chassi
Event Message Reference 33Chassis Intrusion MessagesChassis intrusion messages listed in Table 2-6 are a security measure. Chassis intrusion means tha
34 Event Message ReferenceTable 2-6. Chassis Intrusion MessagesEvent IDDescription Severity Cause1250 Chassis intrusion sensor has failedSensor locati
Event Message Reference 351253 Chassis intrusion in progressSensor location: <Location in chassis>Chassis location: <Name of chassis>Previ
36 Event Message ReferenceRedundancy Unit MessagesRedundancy means that a system chassis has more than one of certain critical components. Fans and po
Event Message Reference 371302 Redundancy not applicableRedundancy unit: <Redundancy location in chassis>Chassis location: <Name of chassis&g
38 Event Message ReferencePower Supply MessagesPower supply sensors monitor how well a power supply is functioning. Power supply messages listed in Ta
Event Message Reference 39Table 2-8. Power Supply MessagesEvent IDDescription Severity Cause1350 Power supply sensor has failed Sensor location: <L
4 ContentsCurrent Sensor Messages . . . . . . . . . . . . . . . . 30Chassis Intrusion Messages . . . . . . . . . . . . . . 33Redundancy Unit Messa
40 Event Message Reference1352 Power supply returned to normal Sensor location: <Location in chassis>Chassis location: <Name of chassis>Pr
Event Message Reference 411354 Power supply detected a failureSensor location: <Location in chassis>Chassis location: <Name of chassis>Pre
42 Event Message ReferenceMemory Device MessagesMemory device messages listed in Table 2-9 provide status and warning information for memory modules p
Event Message Reference 43Fan Enclosure MessagesSome systems are equipped with a protective enclosure for fans. Fan enclosure messages listed in Table
44 Event Message Reference1454 Fan enclosure removed from system for an extended amount of timeSensor location: <Location in chassis>Chassis loc
Event Message Reference 45AC Power Cord MessagesAC power cord messages listed in Table 2-11 provide status and warning information for power cords tha
46 Event Message ReferenceHardware Log Sensor MessagesHardware logs provide hardware status messages to systems management software. On certain system
Event Message Reference 47Table 2-12. Hardware Log Sensor MessagesEvent IDDescription Severity Cause1550 Log monitoring has been disabledLog type: <
48 Event Message ReferenceProcessor Sensor MessagesProcessor sensors monitor how well a processor is functioning. Processor messages listed in Table 2
Event Message Reference 491602 Processor sensor returned to a normal valueSensor Location: <Location in chassis>Chassis Location: <Name of ch
Contents 5Memory Events . . . . . . . . . . . . . . . . . . . . . 65Hardware Log Sensor Events. . . . . . . . . . . . . . 66Drive Events. . . . .
50 Event Message Reference1604 Processor sensor detected a failure valueSensor Location: <Location in chassis>Chassis Location: <Name of chas
Event Message Reference 51Pluggable Device MessagesThe pluggable device messages listed in Table 2-14 provide status and error information when some d
52 Event Message Reference1652 Device removed from systemDevice location: <Location in chassis>Chassis location: <Name of chassis>Addition
Event Message Reference 53Battery Sensor MessagesBattery sensors monitor how well a battery is functioning. Battery messages listed in Table 2-15 prov
54 Event Message Reference1703 Battery sensor detected a warning valueSensor Location: <Location in chassis>Chassis Location: <Name of chassi
Event Message Reference 55Chassis Management Controller MessagesAlerts sent by Dell™ M1000e Chassis Management Controller (CMC) are organized by sever
56 Event Message Reference
System Event Log Messages for IPMI Systems 57System Event Log Messages for IPMI SystemsThe tables in this chapter list the system event log (SEL) mess
58 System Event Log Messages for IPMI SystemsVoltage Sensor EventsThe voltage sensor event messages monitor the number of volts across critical compon
System Event Log Messages for IPMI Systems 59Fan Sensor EventsThe cooling device sensors monitor how well a fan is functioning. These messages provide
6 Contents
60 System Event Log Messages for IPMI Systems<Sensor Name/Location> Fan sensor detected a warning <Reading>.Warning The speed of the speci
System Event Log Messages for IPMI Systems 61Processor Status EventsThe processor status messages monitor the functionality of the processors in a sys
62 System Event Log Messages for IPMI SystemsPower Supply EventsThe power supply sensors monitor the functionality of the power supplies. These messag
System Event Log Messages for IPMI Systems 63<Entity Name> PS Redundancy sensor redundancy degraded.Information Power supply redundancy is degra
64 System Event Log Messages for IPMI SystemsMemory ECC EventsThe memory ECC event messages monitor the memory modules in a system. These messages mon
System Event Log Messages for IPMI Systems 65Memory EventsThe memory modules can be configured in different ways in particular systems. These messages
66 System Event Log Messages for IPMI SystemsHardware Log Sensor EventsThe hardware logs provide hardware status messages to the system management sof
System Event Log Messages for IPMI Systems 67Drive EventsThe drive event messages monitor the health of the drives in a system. These events are gener
68 System Event Log Messages for IPMI SystemsIntrusion EventsThe chassis intrusion messages are a security measure. Chassis intrusion alerts are gener
System Event Log Messages for IPMI Systems 69BIOS Generated System EventsThe BIOS-generated messages monitor the health and functionality of the chips
Introduction 7IntroductionDell™OpenManage™ Server Administrator produces event messages stored primarily in the operating system or Server Administrat
70 System Event Log Messages for IPMI SystemsSystem Event PCIE Fatal Err.Critical This error is generated when a fatal error is detected on the PCIE b
System Event Log Messages for IPMI Systems 71Memory Add(BANK# DIMM#) presence was assertedInformation This event is generated when memory is added to
72 System Event Log Messages for IPMI SystemsUSB Over-currenttransition to non-recoverableCritical This event is generated when the USB exceeds a pred
System Event Log Messages for IPMI Systems 73LinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mezz
74 System Event Log Messages for IPMI SystemsPOST Code TableTable 3-13 lists the POST Code errors that are generated when a fatal error occurs during
System Event Log Messages for IPMI Systems 75R2 Generated System EventsC0 Shutdown test failure This error code indicates a shutdown test failure.C1 P
76 System Event Log Messages for IPMI SystemsCable Interconnect EventsThe cable interconnect messages are used for detecting errors in the hardware ca
System Event Log Messages for IPMI Systems 77Power And Performance EventsThe power and performance events are used to detect degradation in system per
78 System Event Log Messages for IPMI Systems
Storage Management Message Reference 79Storage Management Message ReferenceThe Dell™ OpenManage™ Server Administrator Storage Management’s alert or ev
8 IntroductionWhat’s New in this ReleaseThe following changes have been made to this guide for this release:• Added the following new alerts in the “S
80 Storage Management Message ReferenceAlert Message Format with Substitution Variables When you view an alert in the Server Administrator alert log,
Storage Management Message Reference 81Table 4-2. Message Format with Variables for Each Storage Object Storage Object Message Variables A, B, C and
82 Storage Management Message ReferenceSAS Power SupplyMessage Format: Power Supply X Controller A, Connector B, Enclosure CExample: 2312 A power supp
Storage Management Message Reference 83Alert Message Change HistoryThe following table describes the changes made to the Storage Management alerts fro
84 Storage Management Message ReferenceAlert Descriptions and Corrective ActionsThe following sections describe alerts generated by the RAID or SCSI c
Storage Management Message Reference 85Table 4-4. Storage Management MessagesEventIDDescription Severity Cause and Action Related Alert InformationSNM
86 Storage Management Message Reference2049 Physical disk removedWarning / Non-criticalCause: A physical disk has been removed from the disk group. Th
Storage Management Message Reference 872050 Physical disk offlineWarning / Non-criticalCause: A physical disk in the disk group is offline. The user m
88 Storage Management Message Reference2052 Physical disk insertedOK / Normal / InformationalCause: This alert is for informational purposes. Action:
Storage Management Message Reference 892055 Virtual disk configuration changedOK / Normal / InformationalCause: This alert is for informational purpos
Introduction 9Messages Not Described in This GuideThis guide describes only event messages logged by Server Administrator and Storage Management that
90 Storage Management Message Reference2057 Virtual disk degradedWarning / Non-criticalCause 1: This alert message occurs when a physical disk include
Storage Management Message Reference 912057 contd.Cause 2: A physical disk in the disk group has been removed.Action 2: If a physical disk was removed
92 Storage Management Message Reference2060 Copy of data started on physical disk 1 from physical disk 2.OK / Normal /InformationalCause: This alert i
Storage Management Message Reference 932063 Virtual disk reconfiguration startedOK / Normal / InformationalCause: This alert is for informational purp
94 Storage Management Message Reference2067 Virtual disk check consistency cancelledOK / Normal / InformationalCause: The check consistency operation
Storage Management Message Reference 952070 Virtual disk initialization cancelledOK / Normal / InformationalCause: The virtual disk initialization can
96 Storage Management Message Reference2075 Copy of data completed on physical disk %2 from physical disk %1 OK / Normal / InformationalCause: This al
Storage Management Message Reference 972077 Virtual disk format failedCritical / Failure / ErrorCause: A physical disk included in the virtual disk fa
98 Storage Management Message Reference2081 Virtual disk reconfiguration failedCritical / Failure / ErrorCause: A physical disk included in the virtua
Storage Management Message Reference 992083 Physical disk rebuild failedCritical / Failure / ErrorCause: A physical disk included in the virtual disk
Kommentare zu diesen Handbüchern