Storage Management Message Reference 103
2094
cond.
If this disk is a hot
spare, then unassign the
hot spare; perform the
Prepare to Remove task
on the disk; replace the
disk; and assign the new
disk as a hot spare.
CAUTION: If this
disk is part of a
nonredundant disk, back
up your data
immediately. If the disk
fails, you will not be
able to recover the data.
2095 SCSI sense
data.
OK / Normal /
Informational
Cause: A SCSI device
experienced an error,
but may have recovered.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number: 2273
LRA Number:
None.
751, 851,
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert