Table 1-8. Troubleshooting Your Internal RAID Controller Card
Issue Possible cause Resolution
The status LED on a
hard drive on my
PowerEdge storage
server is blinking
amber.
A hard drive is
offline on the
CERC SATA
controller, which is
most likely caused
by a failed hard
drive or a
disconnected
data/power cable
to the drive or due
to a bad controller.
Run the Dell online hard drive
diagnostics. If the diagnostics do not
indicate a problem, shut down the
PowerEdge storage server. Ensure that
the power and data cables are correctly
connected to the hard drive, and then
reboot the system.
See the Dell OpenManage Server
Administrator documentation on the
system's Resource CD for more
information about how to run the
diagnostics. If the application fails,
replace the hard drive.
The PowerEdge
storage server hangs
during POST.
The controller is
not being
detected.
Shut down the PowerEdge storage server.
Check the PCI riser card connection to
the CERC SATA card and ensure that it
is seated correctly. Also check the cable
and power connections for the hard drives.
If the system still hangs, perform the
following steps:
1
Shut down the PowerEdge storage server.
2
Check the PCI riser connection to the
CERC SATA card.
3
Try installing the CERC SATA card in
the other PCI slot (if available).
4
If the system can now see the card,
replace the riser card.
The CERC SATA
card cannot see any
hard drives attached
to the system.
The hard drives are
not connected
correctly.
Shut down the PowerEdge storage server.
Reseat the CERC SATA card and make
sure that power and data cables from
each of the hard drives are connected to
the CERC SATA card correctly.