Dell PowerVault MD3220 Bedienungsanleitung Seite 263

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 272
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 262
Troubleshooting: Your Array 263
Backplane/power supply failure
Two or more temperature sensors are unreadable
Failure to detect or unable to communicate with peer port
NOTE: If both RAID controller modules fail simultaneously, the enclosure cannot
issue critical or noncritical event alarms for any enclosure component.
When the enclosure is under critical condition, its enclosure status LED
blinks amber.
Noncritical Conditions
A noncritical condition is an event or status that does not cause immediate
failure, but must be corrected to ensure continued reliability of the storage
array. Examples of noncritical events include the following:
One power supply has failed
One cooling fan has failed
One RAID controller module in a redundant configuration has failed
A battery has failed or is removed
A physical disk in a redundant virtual disk has failed
When the enclosure is under noncritical condition, its enclosure status LED
blinks amber.
book.book Page 263 Tuesday, June 18, 2013 2:53 PM