Dell PowerVault MD3860f Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
Figure 4. Fibre/iSCSI Channel Multi-path Configuration
Switch Zoning Requirements
Switches used in a fibre-channel and iSCSI configuration must employ zoning. These switch zoning requirements must
be observed:
Each host bus adapter (HBA) on the host server must connect to a separate switch zone; no more than one HBA may
be connected to one logical switch zone.
Port 3 on each of the MD storage array controller is reserved for Remote Replication. This is required for fibre-
channel only. iSCSI does not require any dedicated port.
For fibre-channel, a separate zone must be created for each Remote Replication port.
No more than four data paths (port-to-port segments) can be established from a single, physical host server to a
single RAID controller.
For additional MD storage array zoning information, see the Deployment Guide for your array at dell.com/support.
For additional VMware-related zoning information, see
VMware Fibre Channel SAN Configuration Guide
at vmware.com/
support/product-support.
10
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare