110 Storage Management Message Reference
2108 Smart
warning
Warning /
Non-
critical
Cause: A disk has received
a SMART alert (predictive
failure). The disk is likely to
fail in the near future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
NOTICE: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert