322 Viewing Statistics
www.dell.com | support.dell.com
• Click Statistics/RMON > RMON> Alarms in the Tree View. The RMON Alarm
page opens.
RMON Alarm Page
The RMON Alarm page contains the following fields:
• Alarm Entry—Indicates a specific alarm.
• Counter Name—Indicates the selected RMON counter.
• Counter Value—Indicates the value of the RMON counter.
• Sample Type—Specifies the sampling method for the selected variable and compares
the value against the thresholds. The possible field values are:
– Delta—Subtracts the last sampled value from the current value. The difference in
the values is compared to the threshold.
– Absolute—Compares the values directly with the thresholds at the end of the
sampling interval.
• Rising Threshold—The rising counter value that triggers the rising threshold alarm.