Seitenansicht 0
Test Engineer
Enterprise Software Validation
Test Engineer
Enterprise Software Validation
Firmware Engineer
Enterprise Firmware
Enhancements to iDRAC7 Alert
Notification
This Dell white paper discusses the improvements made to the
iDRAC7 version 1.30.30 alerting capabilities
Seitenansicht 0
1 2 3 4 5 6 ... 14 15

Inhaltsverzeichnis

Seite 1 - Notification

Test Engineer Enterprise Software Validation Test Engineer Enterprise Software Validation Firmware Engineer Enterprise Firmware Enhance

Seite 2 - Contents

Enhancements to iDRAC7 Alert Notification 10 To configure the SNMP community name string: config command racadm config -g cfgIpmiLan -o cfgIpmiPetCom

Seite 3 - Executive summary

Enhancements to iDRAC7 Alert Notification 11 To demonstrate decoding an IPMI PET alert, see the sample in Figure 7 of an alert caused by a chassis in

Seite 4

Enhancements to iDRAC7 Alert Notification 12 Remote System Log alerts Using iDRAC7 for Dell PowerEdge 12th generation servers, you can configure aler

Seite 5 - Setting event alerts

Enhancements to iDRAC7 Alert Notification 13 Configuring remote syslog using RACADM commands To enable remote syslog: config command racadm config –g

Seite 6 - Email alerts

Enhancements to iDRAC7 Alert Notification 14 Testing configured events After configuring alerts, you can test the configuration of each event. 1. I

Seite 7

Enhancements to iDRAC7 Alert Notification 15 Summary The alert enhancements in the iDRAC7 1.30.30 firmware release provide IT administrators with mor

Seite 8 - SNMP Trap alerts

Enhancements to iDRAC7 Alert Notification ii Contents Executive summary ...

Seite 9

Enhancements to iDRAC7 Alert Notification 3 Executive summary Alerts and actions can be set for certain events that occur on Dell™ PowerEdge™ servers

Seite 10 - IPMI PET alerts

Enhancements to iDRAC7 Alert Notification 4  Additional alert subsystem categories  Column-separated information, such as severity type (info, wa

Seite 11

Enhancements to iDRAC7 Alert Notification 5 Setting event alerts You can configure iDRAC7 to send alerts to configured destinations for a variety of

Seite 12 - Remote System Log alerts

Enhancements to iDRAC7 Alert Notification 6 Email alerts Configuring email alerts using the iDRAC7 web interface 1. Select Overview > Server >

Seite 13 - WS Eventing alerts

Enhancements to iDRAC7 Alert Notification 7 Configuring email alerts using RACADM commands To configure the SMTP email server: set command racadm set

Seite 14 - Testing configured events

Enhancements to iDRAC7 Alert Notification 8 To configure a custom message: config command racadm config -g cfgEmailAlert -o cfgEmailAlertCustomMsg -i

Seite 15 - Summary

Enhancements to iDRAC7 Alert Notification 9 You can then configure up to eight destination addresses for delivery of any SNMP alert. You can configur