1. Open the system. See "Opening the System" in "Troubleshooting Your System."
2. To remove the memory cooling shroud, lift the release latch and slide the shroud forward. See Figure6-16.
Figure 6-16. Removing the Memory Cooling Shroud
3. Locate the memory module sockets. See FigureA-3.
4. Press the ejectors on the memory module socket down and out, as shown in Figure6-17, to allow the memory module to be inserted into the socket.
Figure 6-17. Installing and Removing a Memory Module
5. Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket.
6. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket.
When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that
have memory modules installed.
7. Repeat step 3 through step 6 of this procedure to install the remaining memory modules. See Table6-2 and Table6-3 for sample memory
configurations.
8. Replace the memory cooling shroud.
9. Close the system. See "Closing the System" in "Troubleshooting Your System."
10. (Optional) Press <F2> to enter the System Setup program, and check the System Memory setting on the main System Setup screen.
The system should have already changed the value to reflect the newly installed memory.
NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.